{"title":"采用混合方法为混合可再生能源系统的并网和隔离负载设计双向四端口 DC-DC 转换器","authors":"N. Karthikeyan, G. D. Anbarasi Jebaselvi","doi":"10.1007/s10470-024-02251-6","DOIUrl":null,"url":null,"abstract":"<div><p>Most four-port converters typically enable bidirectional power flow through the low-voltage side battery port, which is used to discharge to the high-voltage side DC-link and charge from energy sources. However, system-level power management is restricted by the DC-link’s absence of bidirectional power transmission. This manuscript proposes a hybrid approach utilizing a four-port DC–DC converter that can operate in isolation and in conjunction with the grid for hybrid renewable energy systems. Moreover, the converter architecture enables bi-directional power flow between all four ports, including the high-voltage DC-link, allowing for flexible and efficient power management. The Random Decision Forest and Jellyfish Search technology are combined to form the JS-RDF technique, which goes by that name. The primary goal of the proposed method is to reduce power losses, enhance system performance, and ensure stable voltage profiles. The JS is used for robust optimization, adapting the converter to various conditions, while the RDF employs machine learning for optimal control pulse prediction, enhancing overall efficiency. The JS-RDF approach is implemented on the MATLAB platform and is compared with existing approaches. Also, the JS-RDF method demonstrates great power compared to other existing approaches. From the result, the proposed technique shows outstanding performance with minimal switching losses at 0.19 W and conduction losses at 0.43 W, leading to the lowest total losses of 0.62 W. This emphasizes the superior efficiency of the proposed approach in optimizing power conversion, highlighting its potential to improve the overall performance of converter systems.</p></div>","PeriodicalId":7827,"journal":{"name":"Analog Integrated Circuits and Signal Processing","volume":"118 3","pages":"467 - 487"},"PeriodicalIF":1.2000,"publicationDate":"2024-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A bidirectional four-port DC–DC converter for grid connected and isolated loads of hybrid renewable energy system using hybrid approach\",\"authors\":\"N. Karthikeyan, G. D. Anbarasi Jebaselvi\",\"doi\":\"10.1007/s10470-024-02251-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Most four-port converters typically enable bidirectional power flow through the low-voltage side battery port, which is used to discharge to the high-voltage side DC-link and charge from energy sources. However, system-level power management is restricted by the DC-link’s absence of bidirectional power transmission. This manuscript proposes a hybrid approach utilizing a four-port DC–DC converter that can operate in isolation and in conjunction with the grid for hybrid renewable energy systems. Moreover, the converter architecture enables bi-directional power flow between all four ports, including the high-voltage DC-link, allowing for flexible and efficient power management. The Random Decision Forest and Jellyfish Search technology are combined to form the JS-RDF technique, which goes by that name. The primary goal of the proposed method is to reduce power losses, enhance system performance, and ensure stable voltage profiles. The JS is used for robust optimization, adapting the converter to various conditions, while the RDF employs machine learning for optimal control pulse prediction, enhancing overall efficiency. The JS-RDF approach is implemented on the MATLAB platform and is compared with existing approaches. Also, the JS-RDF method demonstrates great power compared to other existing approaches. From the result, the proposed technique shows outstanding performance with minimal switching losses at 0.19 W and conduction losses at 0.43 W, leading to the lowest total losses of 0.62 W. This emphasizes the superior efficiency of the proposed approach in optimizing power conversion, highlighting its potential to improve the overall performance of converter systems.</p></div>\",\"PeriodicalId\":7827,\"journal\":{\"name\":\"Analog Integrated Circuits and Signal Processing\",\"volume\":\"118 3\",\"pages\":\"467 - 487\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-02-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analog Integrated Circuits and Signal Processing\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10470-024-02251-6\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"COMPUTER SCIENCE, HARDWARE & ARCHITECTURE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analog Integrated Circuits and Signal Processing","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10470-024-02251-6","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"COMPUTER SCIENCE, HARDWARE & ARCHITECTURE","Score":null,"Total":0}
A bidirectional four-port DC–DC converter for grid connected and isolated loads of hybrid renewable energy system using hybrid approach
Most four-port converters typically enable bidirectional power flow through the low-voltage side battery port, which is used to discharge to the high-voltage side DC-link and charge from energy sources. However, system-level power management is restricted by the DC-link’s absence of bidirectional power transmission. This manuscript proposes a hybrid approach utilizing a four-port DC–DC converter that can operate in isolation and in conjunction with the grid for hybrid renewable energy systems. Moreover, the converter architecture enables bi-directional power flow between all four ports, including the high-voltage DC-link, allowing for flexible and efficient power management. The Random Decision Forest and Jellyfish Search technology are combined to form the JS-RDF technique, which goes by that name. The primary goal of the proposed method is to reduce power losses, enhance system performance, and ensure stable voltage profiles. The JS is used for robust optimization, adapting the converter to various conditions, while the RDF employs machine learning for optimal control pulse prediction, enhancing overall efficiency. The JS-RDF approach is implemented on the MATLAB platform and is compared with existing approaches. Also, the JS-RDF method demonstrates great power compared to other existing approaches. From the result, the proposed technique shows outstanding performance with minimal switching losses at 0.19 W and conduction losses at 0.43 W, leading to the lowest total losses of 0.62 W. This emphasizes the superior efficiency of the proposed approach in optimizing power conversion, highlighting its potential to improve the overall performance of converter systems.
期刊介绍:
Analog Integrated Circuits and Signal Processing is an archival peer reviewed journal dedicated to the design and application of analog, radio frequency (RF), and mixed signal integrated circuits (ICs) as well as signal processing circuits and systems. It features both new research results and tutorial views and reflects the large volume of cutting-edge research activity in the worldwide field today.
A partial list of topics includes analog and mixed signal interface circuits and systems; analog and RFIC design; data converters; active-RC, switched-capacitor, and continuous-time integrated filters; mixed analog/digital VLSI systems; wireless radio transceivers; clock and data recovery circuits; and high speed optoelectronic circuits and systems.