Laura S. Connelly-Smith, James Griffin, Albert T. Leung, Francesca Gennari
{"title":"肝素和枸橼酸盐在体外光子穿刺中使用的现实证据:关于设备设置和性能的假设性数据回顾。","authors":"Laura S. Connelly-Smith, James Griffin, Albert T. Leung, Francesca Gennari","doi":"10.1002/jca.22104","DOIUrl":null,"url":null,"abstract":"<p>Extracorporeal photopheresis (ECP) is widely used for the treatment of cutaneous T-cell lymphoma, graft-vs-host disease, and other immune-related conditions. To avoid clotting during treatment, the ECP system used must be effectively primed with an anticoagulant. Heparin is the recommended anticoagulant for the THERAKOS CELLEX System, but acid citrate dextrose-A (ACDA) is often used. We compared system performance between these two anticoagulants for this ECP system. Deidentified data for ECP device performance were obtained at each treatment session, from automatically logged Smart Cards or labels completed by device operators. We compared the effects of ACDA or heparin on overall treatment duration, buffy coat (leukocyte) collection time, photoactivation time and the number of alarms and warnings. The variability in these parameters was also assessed. Data from 23 334 treat sessions were analyzed; ACDA was used in 34.4% and heparin in 65.6%. Overall, the ECP procedure duration, buffy coat collection time and photoactivation time were numerically similar regardless of whether ACDA or heparin was used, and regardless of needle mode. Photoactivation time variability was lower with ACDA compared with heparin in all needle modes. Among treatments that were completed automatically without any operator intervention, total treatment duration and photoactivation time were significantly reduced with ACDA use in both the double- and single-needle modes. The data presented indicate that, in both double- and single-needle modes, the THERAKOS® CELLEX® integrated ECP system performed similarly with ACDA compared to heparin, although ACDA demonstrated potential benefits in reducing variability in photoactivation time.</p>","PeriodicalId":15390,"journal":{"name":"Journal of Clinical Apheresis","volume":"39 1","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jca.22104","citationCount":"0","resultStr":"{\"title\":\"Real-world evidence of heparin and citrate use in extracorporeal photopheresis: A hypothesis-generating data review of device settings and performance\",\"authors\":\"Laura S. Connelly-Smith, James Griffin, Albert T. Leung, Francesca Gennari\",\"doi\":\"10.1002/jca.22104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Extracorporeal photopheresis (ECP) is widely used for the treatment of cutaneous T-cell lymphoma, graft-vs-host disease, and other immune-related conditions. To avoid clotting during treatment, the ECP system used must be effectively primed with an anticoagulant. Heparin is the recommended anticoagulant for the THERAKOS CELLEX System, but acid citrate dextrose-A (ACDA) is often used. We compared system performance between these two anticoagulants for this ECP system. Deidentified data for ECP device performance were obtained at each treatment session, from automatically logged Smart Cards or labels completed by device operators. We compared the effects of ACDA or heparin on overall treatment duration, buffy coat (leukocyte) collection time, photoactivation time and the number of alarms and warnings. The variability in these parameters was also assessed. Data from 23 334 treat sessions were analyzed; ACDA was used in 34.4% and heparin in 65.6%. Overall, the ECP procedure duration, buffy coat collection time and photoactivation time were numerically similar regardless of whether ACDA or heparin was used, and regardless of needle mode. Photoactivation time variability was lower with ACDA compared with heparin in all needle modes. Among treatments that were completed automatically without any operator intervention, total treatment duration and photoactivation time were significantly reduced with ACDA use in both the double- and single-needle modes. The data presented indicate that, in both double- and single-needle modes, the THERAKOS® CELLEX® integrated ECP system performed similarly with ACDA compared to heparin, although ACDA demonstrated potential benefits in reducing variability in photoactivation time.</p>\",\"PeriodicalId\":15390,\"journal\":{\"name\":\"Journal of Clinical Apheresis\",\"volume\":\"39 1\",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-02-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jca.22104\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Apheresis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jca.22104\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Apheresis","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jca.22104","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
Real-world evidence of heparin and citrate use in extracorporeal photopheresis: A hypothesis-generating data review of device settings and performance
Extracorporeal photopheresis (ECP) is widely used for the treatment of cutaneous T-cell lymphoma, graft-vs-host disease, and other immune-related conditions. To avoid clotting during treatment, the ECP system used must be effectively primed with an anticoagulant. Heparin is the recommended anticoagulant for the THERAKOS CELLEX System, but acid citrate dextrose-A (ACDA) is often used. We compared system performance between these two anticoagulants for this ECP system. Deidentified data for ECP device performance were obtained at each treatment session, from automatically logged Smart Cards or labels completed by device operators. We compared the effects of ACDA or heparin on overall treatment duration, buffy coat (leukocyte) collection time, photoactivation time and the number of alarms and warnings. The variability in these parameters was also assessed. Data from 23 334 treat sessions were analyzed; ACDA was used in 34.4% and heparin in 65.6%. Overall, the ECP procedure duration, buffy coat collection time and photoactivation time were numerically similar regardless of whether ACDA or heparin was used, and regardless of needle mode. Photoactivation time variability was lower with ACDA compared with heparin in all needle modes. Among treatments that were completed automatically without any operator intervention, total treatment duration and photoactivation time were significantly reduced with ACDA use in both the double- and single-needle modes. The data presented indicate that, in both double- and single-needle modes, the THERAKOS® CELLEX® integrated ECP system performed similarly with ACDA compared to heparin, although ACDA demonstrated potential benefits in reducing variability in photoactivation time.
期刊介绍:
The Journal of Clinical Apheresis publishes articles dealing with all aspects of hemapheresis. Articles welcomed for review include those reporting basic research and clinical applications of therapeutic plasma exchange, therapeutic cytapheresis, therapeutic absorption, blood component collection and transfusion, donor recruitment and safety, administration of hemapheresis centers, and innovative applications of hemapheresis technology. Experimental studies, clinical trials, case reports, and concise reviews will be welcomed.