Valentina Marinato, Alice Phillips, Leonardo Giuliano, Tommaso Cascella, Giorgio Greco, Rodolfo Lanocita
{"title":"CEUS 在胆脂瘤治疗中的作用。","authors":"Valentina Marinato, Alice Phillips, Leonardo Giuliano, Tommaso Cascella, Giorgio Greco, Rodolfo Lanocita","doi":"10.1007/s40477-023-00849-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A biloma refers to an abnormal, well-defined accumulation of bile outside the biliary tree within the abdomen, which can be either intra- or extra-hepatic in nature. It can result from traumatic or iatrogenic causes, leading to a disruption in the biliary system. Without prompt diagnosis and appropriate management, it can result in significant morbidity and mortality. While magnetic resonance cholangiopancreatography (MRCP) is the typical diagnostic method, there are instances where it may not provide conclusive results.</p><p><strong>Case presentation: </strong>We present the case of a 72-year-old woman who underwent an hepatic resection of the seventh segment after recurrence of hepatocellular carcinoma (HCC). During the ultrasound (US) follow-up, she developed a peri-hepatic collection which proved to be a biloma continuously refurnished by the biliary tree. Neither the MRCP nor the percutaneous transhepatic cholangiography (PTC) were able to clearly detect the exact site of the bile leak. While awaiting the Endoscopic Retrograde Cholangio-Pancreatography (ERCP), a Contrast-Enhanced Ultrasound (CEUS) was conducted administering the contrast agent directly through the percutaneous drainage catheter placed in the biloma. This revealed the presence of contrast flow from the collection to a peripheral right bile duct, confirming the intra-hepatic leak communication.</p><p><strong>Conclusions: </strong>This case demonstrates that Contrast-Enhanced Ultrasound (CEUS) presents a straightforward, secure, and precise approach to detect biliary leakage responsible for the formation of a biloma. Additionally, the adoption of CEUS offers the dual benefit of minimizing radiation exposure for the patient and obviating the requirement for anesthesia. In summary, CEUS emerges as a compelling alternative to conventional diagnostic methods for effectively managing a biloma.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11333771/pdf/","citationCount":"0","resultStr":"{\"title\":\"The role of CEUS in the management of biloma.\",\"authors\":\"Valentina Marinato, Alice Phillips, Leonardo Giuliano, Tommaso Cascella, Giorgio Greco, Rodolfo Lanocita\",\"doi\":\"10.1007/s40477-023-00849-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>A biloma refers to an abnormal, well-defined accumulation of bile outside the biliary tree within the abdomen, which can be either intra- or extra-hepatic in nature. It can result from traumatic or iatrogenic causes, leading to a disruption in the biliary system. Without prompt diagnosis and appropriate management, it can result in significant morbidity and mortality. While magnetic resonance cholangiopancreatography (MRCP) is the typical diagnostic method, there are instances where it may not provide conclusive results.</p><p><strong>Case presentation: </strong>We present the case of a 72-year-old woman who underwent an hepatic resection of the seventh segment after recurrence of hepatocellular carcinoma (HCC). During the ultrasound (US) follow-up, she developed a peri-hepatic collection which proved to be a biloma continuously refurnished by the biliary tree. Neither the MRCP nor the percutaneous transhepatic cholangiography (PTC) were able to clearly detect the exact site of the bile leak. While awaiting the Endoscopic Retrograde Cholangio-Pancreatography (ERCP), a Contrast-Enhanced Ultrasound (CEUS) was conducted administering the contrast agent directly through the percutaneous drainage catheter placed in the biloma. This revealed the presence of contrast flow from the collection to a peripheral right bile duct, confirming the intra-hepatic leak communication.</p><p><strong>Conclusions: </strong>This case demonstrates that Contrast-Enhanced Ultrasound (CEUS) presents a straightforward, secure, and precise approach to detect biliary leakage responsible for the formation of a biloma. Additionally, the adoption of CEUS offers the dual benefit of minimizing radiation exposure for the patient and obviating the requirement for anesthesia. In summary, CEUS emerges as a compelling alternative to conventional diagnostic methods for effectively managing a biloma.</p>\",\"PeriodicalId\":51528,\"journal\":{\"name\":\"Journal of Ultrasound\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11333771/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ultrasound\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s40477-023-00849-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-023-00849-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/8 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Background: A biloma refers to an abnormal, well-defined accumulation of bile outside the biliary tree within the abdomen, which can be either intra- or extra-hepatic in nature. It can result from traumatic or iatrogenic causes, leading to a disruption in the biliary system. Without prompt diagnosis and appropriate management, it can result in significant morbidity and mortality. While magnetic resonance cholangiopancreatography (MRCP) is the typical diagnostic method, there are instances where it may not provide conclusive results.
Case presentation: We present the case of a 72-year-old woman who underwent an hepatic resection of the seventh segment after recurrence of hepatocellular carcinoma (HCC). During the ultrasound (US) follow-up, she developed a peri-hepatic collection which proved to be a biloma continuously refurnished by the biliary tree. Neither the MRCP nor the percutaneous transhepatic cholangiography (PTC) were able to clearly detect the exact site of the bile leak. While awaiting the Endoscopic Retrograde Cholangio-Pancreatography (ERCP), a Contrast-Enhanced Ultrasound (CEUS) was conducted administering the contrast agent directly through the percutaneous drainage catheter placed in the biloma. This revealed the presence of contrast flow from the collection to a peripheral right bile duct, confirming the intra-hepatic leak communication.
Conclusions: This case demonstrates that Contrast-Enhanced Ultrasound (CEUS) presents a straightforward, secure, and precise approach to detect biliary leakage responsible for the formation of a biloma. Additionally, the adoption of CEUS offers the dual benefit of minimizing radiation exposure for the patient and obviating the requirement for anesthesia. In summary, CEUS emerges as a compelling alternative to conventional diagnostic methods for effectively managing a biloma.
期刊介绍:
The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.