压力约束冠状动脉血流储备的诊断性能。

IF 3.1 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Kazumasa Ikeda, Takashi Kubo, Takahide Murasawa, Haruyuki Deguchi, Kazuya Takihara, Masato Nukariya, Asuka Kuwahara, Tomoaki Nakayama, Miki Kitamura, Taiyo Tezuka, Ryu Takagi, Ryosuke Ito, Shuichiro Kazawa, Yoichi Iwasaki, Satoshi Yamada, Kazuhiro Satomi, Nobuhiro Tanaka
{"title":"压力约束冠状动脉血流储备的诊断性能。","authors":"Kazumasa Ikeda, Takashi Kubo, Takahide Murasawa, Haruyuki Deguchi, Kazuya Takihara, Masato Nukariya, Asuka Kuwahara, Tomoaki Nakayama, Miki Kitamura, Taiyo Tezuka, Ryu Takagi, Ryosuke Ito, Shuichiro Kazawa, Yoichi Iwasaki, Satoshi Yamada, Kazuhiro Satomi, Nobuhiro Tanaka","doi":"10.1007/s12928-024-00983-w","DOIUrl":null,"url":null,"abstract":"<p><p>Fluid dynamics studies have proposed that coronary flow reserve can be calculated from coronary artery pressure instead of coronary blood flow. We sought to investigate the diagnostic performance of pressure-bounded coronary flow reserve (pb-CFR) compared with CFR measured by conventional thermodilution method (CFR<sub>thermo</sub>) in the clinical setting. Pressure guidewire was used to measure CFR<sub>thermo</sub> and fractional flow reserve (FFR) in left anterior descending coronary artery in 62 patients with stable coronary artery disease. Pb-CFR was calculated only with resting distal coronary artery pressure (Pd), resting aortic pressure (Pa) and FFR. Pb-CFR was moderately correlated with CFR<sub>thermo</sub> (r = 0.54, P < 0.001). Pb-CFR showed a poor agreement with CFR<sub>thermo</sub>, presenting large values of mean difference and root mean square deviation (1.5 ± 1.4). Pb-CFR < 2.0 predicted CFR<sub>thermo</sub> < 2.0 with an accuracy of 79%, sensitivity of 83%, specificity of 78%, positive predictive value of 48%, negative predictive value of 95%. The discordance presenting CFR<sub>thermo</sub> < 2.0 and pb-CFR ≥ 2.0 was associated with diffuse disease (P < 0.001). The discordance presenting CFR<sub>thermo</sub> ≥ 2 and pb-CFR < 2 was associated with a high FFR (P = 0.002). Pb-CFR showed moderate correlation and poor agreement with CFR<sub>thermo</sub>. Pb-CFR might be reliable in excluding epicardial coronary artery disease and microcirculatory disorders.</p>","PeriodicalId":9439,"journal":{"name":"Cardiovascular Intervention and Therapeutics","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic performance of pressure-bounded coronary flow reserve.\",\"authors\":\"Kazumasa Ikeda, Takashi Kubo, Takahide Murasawa, Haruyuki Deguchi, Kazuya Takihara, Masato Nukariya, Asuka Kuwahara, Tomoaki Nakayama, Miki Kitamura, Taiyo Tezuka, Ryu Takagi, Ryosuke Ito, Shuichiro Kazawa, Yoichi Iwasaki, Satoshi Yamada, Kazuhiro Satomi, Nobuhiro Tanaka\",\"doi\":\"10.1007/s12928-024-00983-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fluid dynamics studies have proposed that coronary flow reserve can be calculated from coronary artery pressure instead of coronary blood flow. We sought to investigate the diagnostic performance of pressure-bounded coronary flow reserve (pb-CFR) compared with CFR measured by conventional thermodilution method (CFR<sub>thermo</sub>) in the clinical setting. Pressure guidewire was used to measure CFR<sub>thermo</sub> and fractional flow reserve (FFR) in left anterior descending coronary artery in 62 patients with stable coronary artery disease. Pb-CFR was calculated only with resting distal coronary artery pressure (Pd), resting aortic pressure (Pa) and FFR. Pb-CFR was moderately correlated with CFR<sub>thermo</sub> (r = 0.54, P < 0.001). Pb-CFR showed a poor agreement with CFR<sub>thermo</sub>, presenting large values of mean difference and root mean square deviation (1.5 ± 1.4). Pb-CFR < 2.0 predicted CFR<sub>thermo</sub> < 2.0 with an accuracy of 79%, sensitivity of 83%, specificity of 78%, positive predictive value of 48%, negative predictive value of 95%. The discordance presenting CFR<sub>thermo</sub> < 2.0 and pb-CFR ≥ 2.0 was associated with diffuse disease (P < 0.001). The discordance presenting CFR<sub>thermo</sub> ≥ 2 and pb-CFR < 2 was associated with a high FFR (P = 0.002). Pb-CFR showed moderate correlation and poor agreement with CFR<sub>thermo</sub>. Pb-CFR might be reliable in excluding epicardial coronary artery disease and microcirculatory disorders.</p>\",\"PeriodicalId\":9439,\"journal\":{\"name\":\"Cardiovascular Intervention and Therapeutics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Intervention and Therapeutics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s12928-024-00983-w\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Intervention and Therapeutics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12928-024-00983-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

流体动力学研究提出,冠状动脉血流储备可以通过冠状动脉压力而不是冠状动脉血流量来计算。我们试图研究在临床环境中,压力约束冠状动脉血流储备(pb-CFR)与传统热稀释法(CFRthermo)相比的诊断性能。我们使用压力导丝测量了 62 名冠状动脉疾病稳定期患者左前降支冠状动脉的 CFRthermo 和分数血流储备(FFR)。Pb-CFR仅与静息远端冠状动脉压力(Pd)、静息主动脉压力(Pa)和FFR一起计算。Pb-CFR 与 CFRthermo 呈中度相关(r = 0.54,P thermo),平均差和均方根偏差值较大(1.5 ± 1.4)。Pb-CFR thermo thermo ≥ 2,pb-CFR thermo ≥ 2。Pb-CFR 在排除心外膜冠状动脉疾病和微循环障碍方面可能是可靠的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diagnostic performance of pressure-bounded coronary flow reserve.

Fluid dynamics studies have proposed that coronary flow reserve can be calculated from coronary artery pressure instead of coronary blood flow. We sought to investigate the diagnostic performance of pressure-bounded coronary flow reserve (pb-CFR) compared with CFR measured by conventional thermodilution method (CFRthermo) in the clinical setting. Pressure guidewire was used to measure CFRthermo and fractional flow reserve (FFR) in left anterior descending coronary artery in 62 patients with stable coronary artery disease. Pb-CFR was calculated only with resting distal coronary artery pressure (Pd), resting aortic pressure (Pa) and FFR. Pb-CFR was moderately correlated with CFRthermo (r = 0.54, P < 0.001). Pb-CFR showed a poor agreement with CFRthermo, presenting large values of mean difference and root mean square deviation (1.5 ± 1.4). Pb-CFR < 2.0 predicted CFRthermo < 2.0 with an accuracy of 79%, sensitivity of 83%, specificity of 78%, positive predictive value of 48%, negative predictive value of 95%. The discordance presenting CFRthermo < 2.0 and pb-CFR ≥ 2.0 was associated with diffuse disease (P < 0.001). The discordance presenting CFRthermo ≥ 2 and pb-CFR < 2 was associated with a high FFR (P = 0.002). Pb-CFR showed moderate correlation and poor agreement with CFRthermo. Pb-CFR might be reliable in excluding epicardial coronary artery disease and microcirculatory disorders.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cardiovascular Intervention and Therapeutics
Cardiovascular Intervention and Therapeutics CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
6.30
自引率
12.50%
发文量
68
期刊介绍: Cardiovascular Intervention and Therapeutics (CVIT) is an international journal covering the field of cardiovascular disease and includes cardiac (coronary and noncoronary) and peripheral interventions and therapeutics. Articles are subject to peer review and complete editorial evaluation prior to any decision regarding acceptability. CVIT is an official journal of The Japanese Association of Cardiovascular Intervention and Therapeutics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信