{"title":"利用液相色谱-串联质谱法对干血斑中的衍生苯丙氨酸和酪氨酸进行定量,用于新生儿苯丙酮尿症筛查。","authors":"Tsai-Hui Duh, Yu-Ching Liang, Po Tsun Shen, Yi-Wen Ke, Yan-Tian Nian, Shih-Shin Liang","doi":"10.1177/14690667241229626","DOIUrl":null,"url":null,"abstract":"<p><p>Phenylketonuria (PKU) is an autosomal genetic disorder caused by a deficiency of the phenylalanine hydroxylase (PAH) enzyme. The lack of PAH results in the inability of phenylalanine (PHE) to transform into tyrosine (TYR). Consequently, this leads to the accumulation of PHE in the blood samples of newborns causing metabolic diseases such as irreversible neurological problems. An analysis was required for determining the values of PHE and TYR in blood samples from newborn babies. In this study, therefore, we developed a derivatized method to monitor PHE and TYR in plasma samples using liquid phase chromatography linked with quadrupole mass spectrometry. Accessible formaldehyde isotopes and cyanoborohydride were used to react with PHE and TYR amino groups to generate <i>h<sub>2</sub></i>-formaldehyde-modified PHE and TYR (as standards) and <i>d<sub>2</sub></i>-formaldehyde-modified PHE and TYR (as internal standards). We used tandem mass spectrometry for multiple reaction monitoring. We demonstrated a derivatized method suitable for the PKU screening of newborns. The recoveries for PHE and TYR were 85% and 90%, respectively. Furthermore, we compared the values of PHE and TYR in different human plasma sample storage methods, including direct plasma and dried blood spots, and the results showed no significant difference.</p>","PeriodicalId":12007,"journal":{"name":"European Journal of Mass Spectrometry","volume":" ","pages":"133-140"},"PeriodicalIF":1.1000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantification of derivatized phenylalanine and tyrosine in dried blood spots using liquid chromatography with tandem spectrometry for newborn screening of phenylketonuria.\",\"authors\":\"Tsai-Hui Duh, Yu-Ching Liang, Po Tsun Shen, Yi-Wen Ke, Yan-Tian Nian, Shih-Shin Liang\",\"doi\":\"10.1177/14690667241229626\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Phenylketonuria (PKU) is an autosomal genetic disorder caused by a deficiency of the phenylalanine hydroxylase (PAH) enzyme. The lack of PAH results in the inability of phenylalanine (PHE) to transform into tyrosine (TYR). Consequently, this leads to the accumulation of PHE in the blood samples of newborns causing metabolic diseases such as irreversible neurological problems. An analysis was required for determining the values of PHE and TYR in blood samples from newborn babies. In this study, therefore, we developed a derivatized method to monitor PHE and TYR in plasma samples using liquid phase chromatography linked with quadrupole mass spectrometry. Accessible formaldehyde isotopes and cyanoborohydride were used to react with PHE and TYR amino groups to generate <i>h<sub>2</sub></i>-formaldehyde-modified PHE and TYR (as standards) and <i>d<sub>2</sub></i>-formaldehyde-modified PHE and TYR (as internal standards). We used tandem mass spectrometry for multiple reaction monitoring. We demonstrated a derivatized method suitable for the PKU screening of newborns. The recoveries for PHE and TYR were 85% and 90%, respectively. Furthermore, we compared the values of PHE and TYR in different human plasma sample storage methods, including direct plasma and dried blood spots, and the results showed no significant difference.</p>\",\"PeriodicalId\":12007,\"journal\":{\"name\":\"European Journal of Mass Spectrometry\",\"volume\":\" \",\"pages\":\"133-140\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1177/14690667241229626\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/6 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, ATOMIC, MOLECULAR & CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/14690667241229626","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/6 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PHYSICS, ATOMIC, MOLECULAR & CHEMICAL","Score":null,"Total":0}
Quantification of derivatized phenylalanine and tyrosine in dried blood spots using liquid chromatography with tandem spectrometry for newborn screening of phenylketonuria.
Phenylketonuria (PKU) is an autosomal genetic disorder caused by a deficiency of the phenylalanine hydroxylase (PAH) enzyme. The lack of PAH results in the inability of phenylalanine (PHE) to transform into tyrosine (TYR). Consequently, this leads to the accumulation of PHE in the blood samples of newborns causing metabolic diseases such as irreversible neurological problems. An analysis was required for determining the values of PHE and TYR in blood samples from newborn babies. In this study, therefore, we developed a derivatized method to monitor PHE and TYR in plasma samples using liquid phase chromatography linked with quadrupole mass spectrometry. Accessible formaldehyde isotopes and cyanoborohydride were used to react with PHE and TYR amino groups to generate h2-formaldehyde-modified PHE and TYR (as standards) and d2-formaldehyde-modified PHE and TYR (as internal standards). We used tandem mass spectrometry for multiple reaction monitoring. We demonstrated a derivatized method suitable for the PKU screening of newborns. The recoveries for PHE and TYR were 85% and 90%, respectively. Furthermore, we compared the values of PHE and TYR in different human plasma sample storage methods, including direct plasma and dried blood spots, and the results showed no significant difference.
期刊介绍:
JMS - European Journal of Mass Spectrometry, is a peer-reviewed journal, devoted to the publication of innovative research in mass spectrometry. Articles in the journal come from proteomics, metabolomics, petroleomics and other areas developing under the umbrella of the “omic revolution”.