{"title":"胰岛素样生长因子-1 检测面临的挑战。","authors":"Rongrong Huang, Junyan Shi, Ruhan Wei, Jieli Li","doi":"10.1080/10408363.2024.2306804","DOIUrl":null,"url":null,"abstract":"<p><p>Insulin-like growth factor 1 (IGF-1), primarily synthesized in the liver, was initially discovered due to its capacity to replicate the metabolic effects of insulin. Subsequently, it emerged as a key regulator of the actions of growth hormone (GH), managing critical processes like cell proliferation, differentiation, and apoptosis. Notably, IGF-1 displays a longer half-life compared to GH, making it less susceptible to factors that may affect GH concentrations. Consequently, the measurement of IGF-1 proves to be more specific and sensitive when diagnosing conditions such as acromegaly or GH deficiency. The recognition of the existence of IGFBPs and their potential to interfere with IGF-1 immunoassays urged the implementation of various techniques to moderate this issue and provide accurate IGF-1 results. Additionally, in response to the limitations associated with IGF-1 immunoassays and the occurrence of discordant IGF-1 results, modern mass spectrometric methods were developed to facilitate the quantification of IGF-1 levels. Taking advantage of their ability to minimize the interference caused by IGF-1 variants, mass spectrometric methods offer the capacity to deliver robust, reliable, and accurate IGF-1 results, relying on the precision of mass measurements. This also enables the potential detection of pathogenic mutations through protein sequence analysis. However, despite the analytical challenges, the discordance in IGF-1 reference intervals can be attributed to a multitude of factors, potentially leading to distinct interpretations of results. The establishment of reference intervals for each assay is a demanding task, and it requires nationwide multicenter collaboration among laboratorians, clinicians, and assay manufacturers to achieve this common goal in a cost-effective and resource-efficient manner. In this comprehensive review, we examine the challenges associated with the standardization of IGF-1 measurement methods, the minimization of pre-analytical factors, and the harmonization of reference intervals. Particular emphasis will be placed on the development of IGF-1 measurement techniques using \"top-down\" or \"bottom-up\" mass spectrometric methods.</p>","PeriodicalId":10760,"journal":{"name":"Critical reviews in clinical laboratory sciences","volume":" ","pages":"388-403"},"PeriodicalIF":6.6000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Challenges of insulin-like growth factor-1 testing.\",\"authors\":\"Rongrong Huang, Junyan Shi, Ruhan Wei, Jieli Li\",\"doi\":\"10.1080/10408363.2024.2306804\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Insulin-like growth factor 1 (IGF-1), primarily synthesized in the liver, was initially discovered due to its capacity to replicate the metabolic effects of insulin. Subsequently, it emerged as a key regulator of the actions of growth hormone (GH), managing critical processes like cell proliferation, differentiation, and apoptosis. Notably, IGF-1 displays a longer half-life compared to GH, making it less susceptible to factors that may affect GH concentrations. Consequently, the measurement of IGF-1 proves to be more specific and sensitive when diagnosing conditions such as acromegaly or GH deficiency. The recognition of the existence of IGFBPs and their potential to interfere with IGF-1 immunoassays urged the implementation of various techniques to moderate this issue and provide accurate IGF-1 results. Additionally, in response to the limitations associated with IGF-1 immunoassays and the occurrence of discordant IGF-1 results, modern mass spectrometric methods were developed to facilitate the quantification of IGF-1 levels. Taking advantage of their ability to minimize the interference caused by IGF-1 variants, mass spectrometric methods offer the capacity to deliver robust, reliable, and accurate IGF-1 results, relying on the precision of mass measurements. This also enables the potential detection of pathogenic mutations through protein sequence analysis. However, despite the analytical challenges, the discordance in IGF-1 reference intervals can be attributed to a multitude of factors, potentially leading to distinct interpretations of results. The establishment of reference intervals for each assay is a demanding task, and it requires nationwide multicenter collaboration among laboratorians, clinicians, and assay manufacturers to achieve this common goal in a cost-effective and resource-efficient manner. In this comprehensive review, we examine the challenges associated with the standardization of IGF-1 measurement methods, the minimization of pre-analytical factors, and the harmonization of reference intervals. Particular emphasis will be placed on the development of IGF-1 measurement techniques using \\\"top-down\\\" or \\\"bottom-up\\\" mass spectrometric methods.</p>\",\"PeriodicalId\":10760,\"journal\":{\"name\":\"Critical reviews in clinical laboratory sciences\",\"volume\":\" \",\"pages\":\"388-403\"},\"PeriodicalIF\":6.6000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Critical reviews in clinical laboratory sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/10408363.2024.2306804\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical reviews in clinical laboratory sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/10408363.2024.2306804","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
Challenges of insulin-like growth factor-1 testing.
Insulin-like growth factor 1 (IGF-1), primarily synthesized in the liver, was initially discovered due to its capacity to replicate the metabolic effects of insulin. Subsequently, it emerged as a key regulator of the actions of growth hormone (GH), managing critical processes like cell proliferation, differentiation, and apoptosis. Notably, IGF-1 displays a longer half-life compared to GH, making it less susceptible to factors that may affect GH concentrations. Consequently, the measurement of IGF-1 proves to be more specific and sensitive when diagnosing conditions such as acromegaly or GH deficiency. The recognition of the existence of IGFBPs and their potential to interfere with IGF-1 immunoassays urged the implementation of various techniques to moderate this issue and provide accurate IGF-1 results. Additionally, in response to the limitations associated with IGF-1 immunoassays and the occurrence of discordant IGF-1 results, modern mass spectrometric methods were developed to facilitate the quantification of IGF-1 levels. Taking advantage of their ability to minimize the interference caused by IGF-1 variants, mass spectrometric methods offer the capacity to deliver robust, reliable, and accurate IGF-1 results, relying on the precision of mass measurements. This also enables the potential detection of pathogenic mutations through protein sequence analysis. However, despite the analytical challenges, the discordance in IGF-1 reference intervals can be attributed to a multitude of factors, potentially leading to distinct interpretations of results. The establishment of reference intervals for each assay is a demanding task, and it requires nationwide multicenter collaboration among laboratorians, clinicians, and assay manufacturers to achieve this common goal in a cost-effective and resource-efficient manner. In this comprehensive review, we examine the challenges associated with the standardization of IGF-1 measurement methods, the minimization of pre-analytical factors, and the harmonization of reference intervals. Particular emphasis will be placed on the development of IGF-1 measurement techniques using "top-down" or "bottom-up" mass spectrometric methods.
期刊介绍:
Critical Reviews in Clinical Laboratory Sciences publishes comprehensive and high quality review articles in all areas of clinical laboratory science, including clinical biochemistry, hematology, microbiology, pathology, transfusion medicine, genetics, immunology and molecular diagnostics. The reviews critically evaluate the status of current issues in the selected areas, with a focus on clinical laboratory diagnostics and latest advances. The adjective “critical” implies a balanced synthesis of results and conclusions that are frequently contradictory and controversial.