Carlo Jurth, Gregor Lichtner, Thomas Bienert, Falk von Dincklage
{"title":"痛觉屈曲反射阈值测量的变异性主要是由估计算法的概率效应引起的:一项模拟研究。","authors":"Carlo Jurth, Gregor Lichtner, Thomas Bienert, Falk von Dincklage","doi":"10.1080/00207454.2024.2312991","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The nociceptive flexion reflex (NFR) and its threshold are frequently used to investigate spinal nociception in humans. Since this threshold (NFRT) is a probabilistic measure, specific algorithms are used for NFRT estimation based on the stochastic occurrence of reflexes at different stimulus intensities. We used a validated simulation model of the NFR to investigate the amount of NFRT measurement variability induced by different estimation algorithms in a steady setting of reduced external influences.</p><p><strong>Methods: </strong>We simulated the behavior of different estimation algorithms in subjects with an artificially steady baseline NFRT variability (standard deviation: 0 mA) or low baseline NFRT variability (standard deviation: 0.156 mA), equaling a quiet experimental setting. The obtained data were analyzed for NFRT measurement variability caused by the algorithms compared to the baseline variability reflecting other physiological influences.</p><p><strong>Results: </strong>The standard deviation of the NFRT estimated by the different algorithms ranged between 0.381 and 3.464 mA with 96.8% to 99.6% of the measurement variability attributed to the algorithm used. Out of the investigated algorithms the dynamic staircase algorithm was most precise.</p><p><strong>Conclusion: </strong>The NFRT measurement variability observed during quiet and steady experimental sessions is mostly caused by the properties of the estimation algorithms, due to the probabilistic nature of the reflex occurrence. Our results give reference for choosing the optimal estimation algorithm to improve measurement precision.</p>","PeriodicalId":14161,"journal":{"name":"International Journal of Neuroscience","volume":" ","pages":"553-562"},"PeriodicalIF":1.7000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The variability in nociceptive flexion reflex threshold measurement is mostly caused by probabilistic effects of the estimation algorithms: a simulation study.\",\"authors\":\"Carlo Jurth, Gregor Lichtner, Thomas Bienert, Falk von Dincklage\",\"doi\":\"10.1080/00207454.2024.2312991\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The nociceptive flexion reflex (NFR) and its threshold are frequently used to investigate spinal nociception in humans. Since this threshold (NFRT) is a probabilistic measure, specific algorithms are used for NFRT estimation based on the stochastic occurrence of reflexes at different stimulus intensities. We used a validated simulation model of the NFR to investigate the amount of NFRT measurement variability induced by different estimation algorithms in a steady setting of reduced external influences.</p><p><strong>Methods: </strong>We simulated the behavior of different estimation algorithms in subjects with an artificially steady baseline NFRT variability (standard deviation: 0 mA) or low baseline NFRT variability (standard deviation: 0.156 mA), equaling a quiet experimental setting. The obtained data were analyzed for NFRT measurement variability caused by the algorithms compared to the baseline variability reflecting other physiological influences.</p><p><strong>Results: </strong>The standard deviation of the NFRT estimated by the different algorithms ranged between 0.381 and 3.464 mA with 96.8% to 99.6% of the measurement variability attributed to the algorithm used. Out of the investigated algorithms the dynamic staircase algorithm was most precise.</p><p><strong>Conclusion: </strong>The NFRT measurement variability observed during quiet and steady experimental sessions is mostly caused by the properties of the estimation algorithms, due to the probabilistic nature of the reflex occurrence. Our results give reference for choosing the optimal estimation algorithm to improve measurement precision.</p>\",\"PeriodicalId\":14161,\"journal\":{\"name\":\"International Journal of Neuroscience\",\"volume\":\" \",\"pages\":\"553-562\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Neuroscience\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/00207454.2024.2312991\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Neuroscience","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00207454.2024.2312991","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/9 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
The variability in nociceptive flexion reflex threshold measurement is mostly caused by probabilistic effects of the estimation algorithms: a simulation study.
Objectives: The nociceptive flexion reflex (NFR) and its threshold are frequently used to investigate spinal nociception in humans. Since this threshold (NFRT) is a probabilistic measure, specific algorithms are used for NFRT estimation based on the stochastic occurrence of reflexes at different stimulus intensities. We used a validated simulation model of the NFR to investigate the amount of NFRT measurement variability induced by different estimation algorithms in a steady setting of reduced external influences.
Methods: We simulated the behavior of different estimation algorithms in subjects with an artificially steady baseline NFRT variability (standard deviation: 0 mA) or low baseline NFRT variability (standard deviation: 0.156 mA), equaling a quiet experimental setting. The obtained data were analyzed for NFRT measurement variability caused by the algorithms compared to the baseline variability reflecting other physiological influences.
Results: The standard deviation of the NFRT estimated by the different algorithms ranged between 0.381 and 3.464 mA with 96.8% to 99.6% of the measurement variability attributed to the algorithm used. Out of the investigated algorithms the dynamic staircase algorithm was most precise.
Conclusion: The NFRT measurement variability observed during quiet and steady experimental sessions is mostly caused by the properties of the estimation algorithms, due to the probabilistic nature of the reflex occurrence. Our results give reference for choosing the optimal estimation algorithm to improve measurement precision.
期刊介绍:
The International Journal of Neuroscience publishes original research articles, reviews, brief scientific reports, case studies, letters to the editor and book reviews concerned with problems of the nervous system and related clinical studies, epidemiology, neuropathology, medical and surgical treatment options and outcomes, neuropsychology and other topics related to the research and care of persons with neurologic disorders. The focus of the journal is clinical and transitional research. Topics covered include but are not limited to: ALS, ataxia, autism, brain tumors, child neurology, demyelinating diseases, epilepsy, genetics, headache, lysosomal storage disease, mitochondrial dysfunction, movement disorders, multiple sclerosis, myopathy, neurodegenerative diseases, neuromuscular disorders, neuropharmacology, neuropsychiatry, neuropsychology, pain, sleep disorders, stroke, and other areas related to the neurosciences.