使用镍钛诺钉对横向肱骨中轴骨折进行加固固定:手术技术与病例系列》(Augmented Fixation in Transverse Midshaft Humerus Fractures Using a Nitinol Staple: Surgical Technique and Case Series.
{"title":"使用镍钛诺钉对横向肱骨中轴骨折进行加固固定:手术技术与病例系列》(Augmented Fixation in Transverse Midshaft Humerus Fractures Using a Nitinol Staple: Surgical Technique and Case Series.","authors":"Jack G Graham, Daniel E Davis","doi":"10.1097/BTH.0000000000000470","DOIUrl":null,"url":null,"abstract":"<p><p>Maintaining the reduction of a transverse humeral shaft fracture can be particularly challenging while applying a compression plate for definitive fixation. Nitinol compression staples are being increasingly utilized in orthopedic surgery due to their unique ability to apply continuous compression between staple legs at body temperature. We have found them to be particularly useful in the maintenance of the reduction of transverse humeral shaft fractures before compression plate application. This simple technique allows for the removal of reduction clamps and precise plate placement. We describe our technique for using nitinol compression staples to augment fracture fixation in transverse humeral shaft fractures as well as our experience using this technique in a case series of 4 patients.</p>","PeriodicalId":39303,"journal":{"name":"Techniques in Hand and Upper Extremity Surgery","volume":" ","pages":"80-87"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Augmented Fixation in Transverse Midshaft Humerus Fractures Using a Nitinol Staple: Surgical Technique and Case Series.\",\"authors\":\"Jack G Graham, Daniel E Davis\",\"doi\":\"10.1097/BTH.0000000000000470\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Maintaining the reduction of a transverse humeral shaft fracture can be particularly challenging while applying a compression plate for definitive fixation. Nitinol compression staples are being increasingly utilized in orthopedic surgery due to their unique ability to apply continuous compression between staple legs at body temperature. We have found them to be particularly useful in the maintenance of the reduction of transverse humeral shaft fractures before compression plate application. This simple technique allows for the removal of reduction clamps and precise plate placement. We describe our technique for using nitinol compression staples to augment fracture fixation in transverse humeral shaft fractures as well as our experience using this technique in a case series of 4 patients.</p>\",\"PeriodicalId\":39303,\"journal\":{\"name\":\"Techniques in Hand and Upper Extremity Surgery\",\"volume\":\" \",\"pages\":\"80-87\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Techniques in Hand and Upper Extremity Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/BTH.0000000000000470\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Hand and Upper Extremity Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BTH.0000000000000470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Augmented Fixation in Transverse Midshaft Humerus Fractures Using a Nitinol Staple: Surgical Technique and Case Series.
Maintaining the reduction of a transverse humeral shaft fracture can be particularly challenging while applying a compression plate for definitive fixation. Nitinol compression staples are being increasingly utilized in orthopedic surgery due to their unique ability to apply continuous compression between staple legs at body temperature. We have found them to be particularly useful in the maintenance of the reduction of transverse humeral shaft fractures before compression plate application. This simple technique allows for the removal of reduction clamps and precise plate placement. We describe our technique for using nitinol compression staples to augment fracture fixation in transverse humeral shaft fractures as well as our experience using this technique in a case series of 4 patients.
期刊介绍:
Techniques in Hand & Upper Extremity Surgery presents authoritative, practical information on today"s advances in hand and upper extremity surgery. It features articles by leading experts on the latest surgical techniques, the newest equipment, and progress in therapies for rehabilitation. The primary focus of the journal is hand surgery, but articles on the wrist, elbow, and shoulder are also included. Major areas covered include arthroscopy, microvascular surgery, plastic surgery, congenital anomalies, tendon and nerve disorders, trauma, and work-related injuries.