一名红细胞增多症患者的凝血酶原时间检测错误延长:病例报告。

IF 1.2 4区 医学 Q4 HEMATOLOGY
Blood Coagulation & Fibrinolysis Pub Date : 2024-04-01 Epub Date: 2024-01-25 DOI:10.1097/MBC.0000000000001276
Meysam Aghajani Daronkola, Ali Dabbagh, Mahmood Shams, Shadi Tabibian, Soudabeh Hosseini, Seyed Mehrab Safdari, Akbar Dorgalaleh
{"title":"一名红细胞增多症患者的凝血酶原时间检测错误延长:病例报告。","authors":"Meysam Aghajani Daronkola, Ali Dabbagh, Mahmood Shams, Shadi Tabibian, Soudabeh Hosseini, Seyed Mehrab Safdari, Akbar Dorgalaleh","doi":"10.1097/MBC.0000000000001276","DOIUrl":null,"url":null,"abstract":"<p><p>The prothrombin time (PT) test is commonly used to monitor deficiencies in coagulation factors. A prolonged PT may indicate a deficiency of factors II, V, VII, X, and fibrinogen, or the presence of an inhibitor. However, further tests are required to differentiate between a true factor deficiency and the presence of an inhibitor. It is important to note that falsely prolonged PT can lead to misdiagnosis and inappropriate clinical intervention that can have life-threatening consequences. A 19-year-old woman with elevated hematocrit levels and prolonged PT was diagnosed with secondary erythrocytosis due to cyanotic congenital heart disease with ventricular septal defect (VSD). However, further investigation revealed that the prolonged PT result was false. Excess citrate in the blood sample, caused by polycythemia, led to this misleading outcome, resulting in unnecessary and potentially harmful treatment. This incident emphasizes the importance of laboratory personnel and clinicians being aware of the test's limitations. Not only should specialists in thrombosis and hemostasis possess this knowledge, but it is also pertinent for general laboratory staff, as well as laboratory directors and specialists. The significance of accurate laboratory testing for the proper diagnosis and treatment of patients is highlighted in this case.</p>","PeriodicalId":8992,"journal":{"name":"Blood Coagulation & Fibrinolysis","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Falsely prolonged prothrombin time test in a patient with erythrocytosis: a case report.\",\"authors\":\"Meysam Aghajani Daronkola, Ali Dabbagh, Mahmood Shams, Shadi Tabibian, Soudabeh Hosseini, Seyed Mehrab Safdari, Akbar Dorgalaleh\",\"doi\":\"10.1097/MBC.0000000000001276\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The prothrombin time (PT) test is commonly used to monitor deficiencies in coagulation factors. A prolonged PT may indicate a deficiency of factors II, V, VII, X, and fibrinogen, or the presence of an inhibitor. However, further tests are required to differentiate between a true factor deficiency and the presence of an inhibitor. It is important to note that falsely prolonged PT can lead to misdiagnosis and inappropriate clinical intervention that can have life-threatening consequences. A 19-year-old woman with elevated hematocrit levels and prolonged PT was diagnosed with secondary erythrocytosis due to cyanotic congenital heart disease with ventricular septal defect (VSD). However, further investigation revealed that the prolonged PT result was false. Excess citrate in the blood sample, caused by polycythemia, led to this misleading outcome, resulting in unnecessary and potentially harmful treatment. This incident emphasizes the importance of laboratory personnel and clinicians being aware of the test's limitations. Not only should specialists in thrombosis and hemostasis possess this knowledge, but it is also pertinent for general laboratory staff, as well as laboratory directors and specialists. The significance of accurate laboratory testing for the proper diagnosis and treatment of patients is highlighted in this case.</p>\",\"PeriodicalId\":8992,\"journal\":{\"name\":\"Blood Coagulation & Fibrinolysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Blood Coagulation & Fibrinolysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MBC.0000000000001276\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Coagulation & Fibrinolysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBC.0000000000001276","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/25 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

凝血酶原时间(PT)检测通常用于监测凝血因子的缺乏。凝血酶原时间延长可能表明因子 II、V、VII、X 和纤维蛋白原缺乏或存在抑制因子。然而,要区分是真正的因子缺乏还是存在抑制因子,还需要进一步的检测。值得注意的是,PT 假性延长可能导致误诊和不恰当的临床干预,从而造成危及生命的后果。一名血细胞比容升高且 PT 延长的 19 岁女性被诊断为紫绀型先天性心脏病伴室间隔缺损(VSD)引起的继发性红细胞增多症。然而,进一步检查发现,PT 延长的结果是错误的。多血细胞症导致血样中柠檬酸盐过量,导致了这一误导性结果,从而导致了不必要且可能有害的治疗。这一事件强调了实验室人员和临床医生了解检测局限性的重要性。不仅血栓与止血方面的专家应掌握这方面的知识,普通实验室工作人员以及实验室主任和专家也应了解这方面的知识。本病例强调了准确的实验室检测对正确诊断和治疗病人的重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Falsely prolonged prothrombin time test in a patient with erythrocytosis: a case report.

The prothrombin time (PT) test is commonly used to monitor deficiencies in coagulation factors. A prolonged PT may indicate a deficiency of factors II, V, VII, X, and fibrinogen, or the presence of an inhibitor. However, further tests are required to differentiate between a true factor deficiency and the presence of an inhibitor. It is important to note that falsely prolonged PT can lead to misdiagnosis and inappropriate clinical intervention that can have life-threatening consequences. A 19-year-old woman with elevated hematocrit levels and prolonged PT was diagnosed with secondary erythrocytosis due to cyanotic congenital heart disease with ventricular septal defect (VSD). However, further investigation revealed that the prolonged PT result was false. Excess citrate in the blood sample, caused by polycythemia, led to this misleading outcome, resulting in unnecessary and potentially harmful treatment. This incident emphasizes the importance of laboratory personnel and clinicians being aware of the test's limitations. Not only should specialists in thrombosis and hemostasis possess this knowledge, but it is also pertinent for general laboratory staff, as well as laboratory directors and specialists. The significance of accurate laboratory testing for the proper diagnosis and treatment of patients is highlighted in this case.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
111
审稿时长
4-8 weeks
期刊介绍: Blood Coagulation & Fibrinolysis is an international fully refereed journal that features review and original research articles on all clinical, laboratory and experimental aspects of haemostasis and thrombosis. The journal is devoted to publishing significant developments worldwide in the field of blood coagulation, fibrinolysis, thrombosis, platelets and the kininogen-kinin system, as well as dealing with those aspects of blood rheology relevant to haemostasis and the effects of drugs on haemostatic components
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信