Meysam Aghajani Daronkola, Ali Dabbagh, Mahmood Shams, Shadi Tabibian, Soudabeh Hosseini, Seyed Mehrab Safdari, Akbar Dorgalaleh
{"title":"一名红细胞增多症患者的凝血酶原时间检测错误延长:病例报告。","authors":"Meysam Aghajani Daronkola, Ali Dabbagh, Mahmood Shams, Shadi Tabibian, Soudabeh Hosseini, Seyed Mehrab Safdari, Akbar Dorgalaleh","doi":"10.1097/MBC.0000000000001276","DOIUrl":null,"url":null,"abstract":"<p><p>The prothrombin time (PT) test is commonly used to monitor deficiencies in coagulation factors. A prolonged PT may indicate a deficiency of factors II, V, VII, X, and fibrinogen, or the presence of an inhibitor. However, further tests are required to differentiate between a true factor deficiency and the presence of an inhibitor. It is important to note that falsely prolonged PT can lead to misdiagnosis and inappropriate clinical intervention that can have life-threatening consequences. A 19-year-old woman with elevated hematocrit levels and prolonged PT was diagnosed with secondary erythrocytosis due to cyanotic congenital heart disease with ventricular septal defect (VSD). However, further investigation revealed that the prolonged PT result was false. Excess citrate in the blood sample, caused by polycythemia, led to this misleading outcome, resulting in unnecessary and potentially harmful treatment. This incident emphasizes the importance of laboratory personnel and clinicians being aware of the test's limitations. Not only should specialists in thrombosis and hemostasis possess this knowledge, but it is also pertinent for general laboratory staff, as well as laboratory directors and specialists. The significance of accurate laboratory testing for the proper diagnosis and treatment of patients is highlighted in this case.</p>","PeriodicalId":8992,"journal":{"name":"Blood Coagulation & Fibrinolysis","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Falsely prolonged prothrombin time test in a patient with erythrocytosis: a case report.\",\"authors\":\"Meysam Aghajani Daronkola, Ali Dabbagh, Mahmood Shams, Shadi Tabibian, Soudabeh Hosseini, Seyed Mehrab Safdari, Akbar Dorgalaleh\",\"doi\":\"10.1097/MBC.0000000000001276\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The prothrombin time (PT) test is commonly used to monitor deficiencies in coagulation factors. A prolonged PT may indicate a deficiency of factors II, V, VII, X, and fibrinogen, or the presence of an inhibitor. However, further tests are required to differentiate between a true factor deficiency and the presence of an inhibitor. It is important to note that falsely prolonged PT can lead to misdiagnosis and inappropriate clinical intervention that can have life-threatening consequences. A 19-year-old woman with elevated hematocrit levels and prolonged PT was diagnosed with secondary erythrocytosis due to cyanotic congenital heart disease with ventricular septal defect (VSD). However, further investigation revealed that the prolonged PT result was false. Excess citrate in the blood sample, caused by polycythemia, led to this misleading outcome, resulting in unnecessary and potentially harmful treatment. This incident emphasizes the importance of laboratory personnel and clinicians being aware of the test's limitations. Not only should specialists in thrombosis and hemostasis possess this knowledge, but it is also pertinent for general laboratory staff, as well as laboratory directors and specialists. The significance of accurate laboratory testing for the proper diagnosis and treatment of patients is highlighted in this case.</p>\",\"PeriodicalId\":8992,\"journal\":{\"name\":\"Blood Coagulation & Fibrinolysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Blood Coagulation & Fibrinolysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MBC.0000000000001276\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Coagulation & Fibrinolysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBC.0000000000001276","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/25 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
Falsely prolonged prothrombin time test in a patient with erythrocytosis: a case report.
The prothrombin time (PT) test is commonly used to monitor deficiencies in coagulation factors. A prolonged PT may indicate a deficiency of factors II, V, VII, X, and fibrinogen, or the presence of an inhibitor. However, further tests are required to differentiate between a true factor deficiency and the presence of an inhibitor. It is important to note that falsely prolonged PT can lead to misdiagnosis and inappropriate clinical intervention that can have life-threatening consequences. A 19-year-old woman with elevated hematocrit levels and prolonged PT was diagnosed with secondary erythrocytosis due to cyanotic congenital heart disease with ventricular septal defect (VSD). However, further investigation revealed that the prolonged PT result was false. Excess citrate in the blood sample, caused by polycythemia, led to this misleading outcome, resulting in unnecessary and potentially harmful treatment. This incident emphasizes the importance of laboratory personnel and clinicians being aware of the test's limitations. Not only should specialists in thrombosis and hemostasis possess this knowledge, but it is also pertinent for general laboratory staff, as well as laboratory directors and specialists. The significance of accurate laboratory testing for the proper diagnosis and treatment of patients is highlighted in this case.
期刊介绍:
Blood Coagulation & Fibrinolysis is an international fully refereed journal that features review and original research articles on all clinical, laboratory and experimental aspects of haemostasis and thrombosis. The journal is devoted to publishing significant developments worldwide in the field of blood coagulation, fibrinolysis, thrombosis, platelets and the kininogen-kinin system, as well as dealing with those aspects of blood rheology relevant to haemostasis and the effects of drugs on haemostatic components