{"title":"Arteriograph 24 用于评估 2 型糖尿病患者和非糖尿病对照组 24 小时脉搏波速度和中心血压的可行性。","authors":"Esben Laugesen, Amalie Nørkjær Svendsen, Liv Vernstrøm, Lene Halkjær, Anna Dons-Jensen, Kristian L Funck, Klavs Würgler Hansen, Per Løgstrup Poulsen","doi":"10.1097/MBP.0000000000000689","DOIUrl":null,"url":null,"abstract":"<p><p>The objective of this study was to assess the feasibility of the Arteriograph 24 device to measure 24-hour PWV and central systolic blood pressure (cSBP) in patients with type 2 diabetes (T2DM) and non-diabetic controls and compare daytime and nighttime characteristics in the two groups. Twenty-four-hour PWV and cSBP was measured in 58 patients with T2DM (mean age: 66 ± 9 years, 50% women, mean duration of T2DM: 7.8 ± 1.5 years) and 62 age- and sex-matched controls. Seventy percent of participants (71% T2DM patients and 69% controls) had sufficient readings to generate an acceptable 24-hour report (≥14 day and ≥7 night readings). Lower nocturnal than daytime PWV and cSBP were observed in both groups. Nocturnal PWV and cSBP dipping were attenuated in T2DM patients compared to controls (PWV: -0.3 ± 0.9 vs. -0.7 ± 0.9 m/s, P = 0.04, cSBP: -8 ± 14 vs. -18 ± 18 mmHg, P < 0.01). No group differences in PWV or cSBP were observed during daytime (T2D vs. controls, PWV: 9.2 ± 1.1 vs. 9.2 ± 1.3 m/s, P = 0.99, cSBP: 133 ± 19 vs. 137 ± 25 mmHg, P = 0.42) or nighttime (PWV: 8.9 ± 1.3 vs. 8.4 ± 1.3 m/s, P = 0.14, cSBP 124 ± 20 vs. 118 ± 27 mmHg, P = 0.26). The study findings indicate that the nocturnal dipping of PWV and cSBP is attenuated in T2DM patients. The significant number of missing measurements raises concerns regarding the clinical utility of the Arteriograph 24 device.</p>","PeriodicalId":8950,"journal":{"name":"Blood Pressure Monitoring","volume":" ","pages":"82-88"},"PeriodicalIF":1.2000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility of Arteriograph 24 for evaluation of 24-hour pulse wave velocity and central blood pressure in patients with type 2 diabetes and non-diabetic controls.\",\"authors\":\"Esben Laugesen, Amalie Nørkjær Svendsen, Liv Vernstrøm, Lene Halkjær, Anna Dons-Jensen, Kristian L Funck, Klavs Würgler Hansen, Per Løgstrup Poulsen\",\"doi\":\"10.1097/MBP.0000000000000689\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The objective of this study was to assess the feasibility of the Arteriograph 24 device to measure 24-hour PWV and central systolic blood pressure (cSBP) in patients with type 2 diabetes (T2DM) and non-diabetic controls and compare daytime and nighttime characteristics in the two groups. Twenty-four-hour PWV and cSBP was measured in 58 patients with T2DM (mean age: 66 ± 9 years, 50% women, mean duration of T2DM: 7.8 ± 1.5 years) and 62 age- and sex-matched controls. Seventy percent of participants (71% T2DM patients and 69% controls) had sufficient readings to generate an acceptable 24-hour report (≥14 day and ≥7 night readings). Lower nocturnal than daytime PWV and cSBP were observed in both groups. Nocturnal PWV and cSBP dipping were attenuated in T2DM patients compared to controls (PWV: -0.3 ± 0.9 vs. -0.7 ± 0.9 m/s, P = 0.04, cSBP: -8 ± 14 vs. -18 ± 18 mmHg, P < 0.01). No group differences in PWV or cSBP were observed during daytime (T2D vs. controls, PWV: 9.2 ± 1.1 vs. 9.2 ± 1.3 m/s, P = 0.99, cSBP: 133 ± 19 vs. 137 ± 25 mmHg, P = 0.42) or nighttime (PWV: 8.9 ± 1.3 vs. 8.4 ± 1.3 m/s, P = 0.14, cSBP 124 ± 20 vs. 118 ± 27 mmHg, P = 0.26). The study findings indicate that the nocturnal dipping of PWV and cSBP is attenuated in T2DM patients. The significant number of missing measurements raises concerns regarding the clinical utility of the Arteriograph 24 device.</p>\",\"PeriodicalId\":8950,\"journal\":{\"name\":\"Blood Pressure Monitoring\",\"volume\":\" \",\"pages\":\"82-88\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Blood Pressure Monitoring\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MBP.0000000000000689\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Pressure Monitoring","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBP.0000000000000689","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/15 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
Feasibility of Arteriograph 24 for evaluation of 24-hour pulse wave velocity and central blood pressure in patients with type 2 diabetes and non-diabetic controls.
The objective of this study was to assess the feasibility of the Arteriograph 24 device to measure 24-hour PWV and central systolic blood pressure (cSBP) in patients with type 2 diabetes (T2DM) and non-diabetic controls and compare daytime and nighttime characteristics in the two groups. Twenty-four-hour PWV and cSBP was measured in 58 patients with T2DM (mean age: 66 ± 9 years, 50% women, mean duration of T2DM: 7.8 ± 1.5 years) and 62 age- and sex-matched controls. Seventy percent of participants (71% T2DM patients and 69% controls) had sufficient readings to generate an acceptable 24-hour report (≥14 day and ≥7 night readings). Lower nocturnal than daytime PWV and cSBP were observed in both groups. Nocturnal PWV and cSBP dipping were attenuated in T2DM patients compared to controls (PWV: -0.3 ± 0.9 vs. -0.7 ± 0.9 m/s, P = 0.04, cSBP: -8 ± 14 vs. -18 ± 18 mmHg, P < 0.01). No group differences in PWV or cSBP were observed during daytime (T2D vs. controls, PWV: 9.2 ± 1.1 vs. 9.2 ± 1.3 m/s, P = 0.99, cSBP: 133 ± 19 vs. 137 ± 25 mmHg, P = 0.42) or nighttime (PWV: 8.9 ± 1.3 vs. 8.4 ± 1.3 m/s, P = 0.14, cSBP 124 ± 20 vs. 118 ± 27 mmHg, P = 0.26). The study findings indicate that the nocturnal dipping of PWV and cSBP is attenuated in T2DM patients. The significant number of missing measurements raises concerns regarding the clinical utility of the Arteriograph 24 device.
期刊介绍:
Blood Pressure Monitoring is devoted to original research in blood pressure measurement and blood pressure variability. It includes device technology, analytical methodology of blood pressure over time and its variability, clinical trials - including, but not limited to, pharmacology - involving blood pressure monitoring, blood pressure reactivity, patient evaluation, and outcomes and effectiveness research.
This innovative journal contains papers dealing with all aspects of manual, automated, and ambulatory monitoring. Basic and clinical science papers are considered although the emphasis is on clinical medicine.
Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.