双能计算机断层扫描无法在临床中有效区分焦磷酸钙和基本磷酸钙疾病

Mohamed Jarraya , Olivier Bitoun , Dufan Wu , Rene Balza , Ali Guermazi , Jamie Collins , Rajiv Gupta , Gunnlaugur Petur Nielsen , Elias Guermazi , F. Joseph Simeone , Patrick Omoumi , Christopher M. Melnic , Seonghwan Yee
{"title":"双能计算机断层扫描无法在临床中有效区分焦磷酸钙和基本磷酸钙疾病","authors":"Mohamed Jarraya ,&nbsp;Olivier Bitoun ,&nbsp;Dufan Wu ,&nbsp;Rene Balza ,&nbsp;Ali Guermazi ,&nbsp;Jamie Collins ,&nbsp;Rajiv Gupta ,&nbsp;Gunnlaugur Petur Nielsen ,&nbsp;Elias Guermazi ,&nbsp;F. Joseph Simeone ,&nbsp;Patrick Omoumi ,&nbsp;Christopher M. Melnic ,&nbsp;Seonghwan Yee","doi":"10.1016/j.ocarto.2024.100436","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Recent reports suggested that dual-energy CT (DECT) may help discriminate between different types of calcium phosphate crystals <em>in vivo</em>, which would have important implications for the characterization of crystal deposition occurring in osteoarthritis.</p></div><div><h3>Purpose</h3><p>Our aim was to test the hypothesis that DECT can effectively differentiate basic calcium phosphate (BCP) from calcium pyrophosphate (CPP) deposition diseases.</p></div><div><h3>Methods</h3><p>Discarded tissue after total knee replacement specimens in a 71year-old patient with knee osteoarthritis and chondrocalcinosis was scanned using DECT at standard clinical parameters. Specimens were then examined on light microscopy which revealed CPP deposition in 4 specimens (medial femoral condyle, lateral tibial plateau and both menisci) without BCP deposition. Regions of interest were placed on post-processed CT images using Rho/Z maps (Syngo.via, Siemens Healthineers, VB10B) in different areas of CPP deposition, trabecular bone BCP (T-BCP) and subchondral bone plate BCP (C-BCP).</p></div><div><h3>Results</h3><p>Dual Energy Index (DEI) of CPP was 0.12 (SD=0.02) for reader 1 and 0.09 (SD=0.03) for reader 2, The effective atomic number (Z<sub><em>eff</em></sub>) of CPP was 10.83 (SD=0.44) for reader 1 and 10.11 (SD=0.66) for reader 2. Nearly all DECT parameters of CPP were higher than those of T-BCP, lower than those of C-BCP, and largely overlapping with Aggregate-BCP (aggregate of T-BCP and C-BCP).</p></div><div><h3>Conclusion</h3><p>Differentiation of different types of calcium crystals using DECT is not feasible in a clinical setting.</p></div>","PeriodicalId":74377,"journal":{"name":"Osteoarthritis and cartilage open","volume":"6 1","pages":"Article 100436"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2665913124000037/pdfft?md5=9d61c0aec17055802b00f66a6deb51f1&pid=1-s2.0-S2665913124000037-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Dual Energy Computed Tomography Cannot Effectively Differentiate Between Calcium Pyrophosphate and Basic Calcium Phosphate Diseases in the Clinical Setting\",\"authors\":\"Mohamed Jarraya ,&nbsp;Olivier Bitoun ,&nbsp;Dufan Wu ,&nbsp;Rene Balza ,&nbsp;Ali Guermazi ,&nbsp;Jamie Collins ,&nbsp;Rajiv Gupta ,&nbsp;Gunnlaugur Petur Nielsen ,&nbsp;Elias Guermazi ,&nbsp;F. Joseph Simeone ,&nbsp;Patrick Omoumi ,&nbsp;Christopher M. Melnic ,&nbsp;Seonghwan Yee\",\"doi\":\"10.1016/j.ocarto.2024.100436\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Recent reports suggested that dual-energy CT (DECT) may help discriminate between different types of calcium phosphate crystals <em>in vivo</em>, which would have important implications for the characterization of crystal deposition occurring in osteoarthritis.</p></div><div><h3>Purpose</h3><p>Our aim was to test the hypothesis that DECT can effectively differentiate basic calcium phosphate (BCP) from calcium pyrophosphate (CPP) deposition diseases.</p></div><div><h3>Methods</h3><p>Discarded tissue after total knee replacement specimens in a 71year-old patient with knee osteoarthritis and chondrocalcinosis was scanned using DECT at standard clinical parameters. Specimens were then examined on light microscopy which revealed CPP deposition in 4 specimens (medial femoral condyle, lateral tibial plateau and both menisci) without BCP deposition. Regions of interest were placed on post-processed CT images using Rho/Z maps (Syngo.via, Siemens Healthineers, VB10B) in different areas of CPP deposition, trabecular bone BCP (T-BCP) and subchondral bone plate BCP (C-BCP).</p></div><div><h3>Results</h3><p>Dual Energy Index (DEI) of CPP was 0.12 (SD=0.02) for reader 1 and 0.09 (SD=0.03) for reader 2, The effective atomic number (Z<sub><em>eff</em></sub>) of CPP was 10.83 (SD=0.44) for reader 1 and 10.11 (SD=0.66) for reader 2. Nearly all DECT parameters of CPP were higher than those of T-BCP, lower than those of C-BCP, and largely overlapping with Aggregate-BCP (aggregate of T-BCP and C-BCP).</p></div><div><h3>Conclusion</h3><p>Differentiation of different types of calcium crystals using DECT is not feasible in a clinical setting.</p></div>\",\"PeriodicalId\":74377,\"journal\":{\"name\":\"Osteoarthritis and cartilage open\",\"volume\":\"6 1\",\"pages\":\"Article 100436\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2665913124000037/pdfft?md5=9d61c0aec17055802b00f66a6deb51f1&pid=1-s2.0-S2665913124000037-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Osteoarthritis and cartilage open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2665913124000037\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Osteoarthritis and cartilage open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2665913124000037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景最近有报道称,双能 CT(DECT)可能有助于区分体内不同类型的磷酸钙晶体,这将对骨关节炎中晶体沉积的特征描述产生重要影响。我们的目的是检验 DECT 是否能有效区分基本磷酸钙 (BCP) 和焦磷酸钙 (CPP) 沉积疾病的假设。方法:在标准临床参数下使用 DECT 扫描一名 71 岁膝关节骨关节炎和软骨钙化症患者全膝关节置换术后标本的废弃组织。然后对标本进行光学显微镜检查,结果显示 4 个标本(股骨内侧髁、胫骨外侧平台和两个半月板)中有 CPP 沉积,但无 BCP 沉积。在 CPP 沉积、骨小梁 BCP(T-BCP)和软骨下骨板 BCP(C-BCP)的不同区域,使用 Rho/Z 地图(Syngo.via,Siemens Healthineers,VB10B)在后处理的 CT 图像上放置感兴趣区。结果 CPP 的双能指数(DEI)在阅读器 1 中为 0.12(SD=0.02),在阅读器 2 中为 0.09(SD=0.03);CPP 的有效原子序数(Zeff)在阅读器 1 中为 10.83(SD=0.44),在阅读器 2 中为 10.11(SD=0.66)。CPP 的几乎所有 DECT 参数都高于 T-BCP,低于 C-BCP,并与 Aggregate-BCP(T-BCP 和 C-BCP 的集合体)基本重叠。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dual Energy Computed Tomography Cannot Effectively Differentiate Between Calcium Pyrophosphate and Basic Calcium Phosphate Diseases in the Clinical Setting

Background

Recent reports suggested that dual-energy CT (DECT) may help discriminate between different types of calcium phosphate crystals in vivo, which would have important implications for the characterization of crystal deposition occurring in osteoarthritis.

Purpose

Our aim was to test the hypothesis that DECT can effectively differentiate basic calcium phosphate (BCP) from calcium pyrophosphate (CPP) deposition diseases.

Methods

Discarded tissue after total knee replacement specimens in a 71year-old patient with knee osteoarthritis and chondrocalcinosis was scanned using DECT at standard clinical parameters. Specimens were then examined on light microscopy which revealed CPP deposition in 4 specimens (medial femoral condyle, lateral tibial plateau and both menisci) without BCP deposition. Regions of interest were placed on post-processed CT images using Rho/Z maps (Syngo.via, Siemens Healthineers, VB10B) in different areas of CPP deposition, trabecular bone BCP (T-BCP) and subchondral bone plate BCP (C-BCP).

Results

Dual Energy Index (DEI) of CPP was 0.12 (SD=0.02) for reader 1 and 0.09 (SD=0.03) for reader 2, The effective atomic number (Zeff) of CPP was 10.83 (SD=0.44) for reader 1 and 10.11 (SD=0.66) for reader 2. Nearly all DECT parameters of CPP were higher than those of T-BCP, lower than those of C-BCP, and largely overlapping with Aggregate-BCP (aggregate of T-BCP and C-BCP).

Conclusion

Differentiation of different types of calcium crystals using DECT is not feasible in a clinical setting.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Osteoarthritis and cartilage open
Osteoarthritis and cartilage open Orthopedics, Sports Medicine and Rehabilitation
CiteScore
3.30
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信