{"title":"基于红外光谱测量的变压器绝缘油故障诊断新技术","authors":"Mohamed M. F. Darwish, Mohamed H. A. Hassan, Nagat M. K. Abdel-Gawad, Matti Lehtonen, Diaa-Eldin A. Mansour","doi":"10.1049/hve2.12405","DOIUrl":null,"url":null,"abstract":"<p>Condition monitoring of the insulating system within power transformers has a massive importance according to the electrical utilities. Dissolved gas analysis (DGA) is frequently used for this purpose. However, DGA lacks the necessary level of accuracy to identify all equipment faults, particularly in their initial stages of degradation. Also, it does not have the capability for real-time monitoring and relies on manual sampling and laboratory testing, causing potential delays in fault identification. Additionally, the interpretation of DGA data necessitates specialised expertise, which may pose difficulties for smaller entities that have limited access to resources. Therefore, the contribution of this research is to use infrared spectroscopy measurements as a new effective technique substituting the DGA method for fault diagnosis in insulating oil. The inception faults that were considered in this study were the electrical fault (discharges of high energy) and the thermal fault (300°C < Temperature < 700°C). Regarding that, two test cells were crafted especially for serving the simulation processes inside the laboratory for both types of inception faults. Subsequently, six samples of pure paraffinic mineral oil were taken to be degraded in the laboratory. Following that, all of them besides another sample that were not subjected to any kind of faults were taken to be examined by Fourier transform infrared (FTIR) spectroscopy to obtain an overview of the oil's behaviour in each fault case. After that, the FTIR analysis was initially verified utilising the DGA method. Then, for further affirmation, the dielectric dissipation factor (DDF) for all samples was measured. In the final analysis, the verification tests provide experimental evidence about the outperformance of this new optical technique in detecting the transformer's inception faults in addition to proving its potential for being a superior alternative to the well-known traditional diagnostic techniques.</p>","PeriodicalId":48649,"journal":{"name":"High Voltage","volume":"9 2","pages":"319-335"},"PeriodicalIF":4.4000,"publicationDate":"2024-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/hve2.12405","citationCount":"0","resultStr":"{\"title\":\"A new technique for fault diagnosis in transformer insulating oil based on infrared spectroscopy measurements\",\"authors\":\"Mohamed M. F. Darwish, Mohamed H. A. Hassan, Nagat M. K. Abdel-Gawad, Matti Lehtonen, Diaa-Eldin A. Mansour\",\"doi\":\"10.1049/hve2.12405\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Condition monitoring of the insulating system within power transformers has a massive importance according to the electrical utilities. Dissolved gas analysis (DGA) is frequently used for this purpose. However, DGA lacks the necessary level of accuracy to identify all equipment faults, particularly in their initial stages of degradation. Also, it does not have the capability for real-time monitoring and relies on manual sampling and laboratory testing, causing potential delays in fault identification. Additionally, the interpretation of DGA data necessitates specialised expertise, which may pose difficulties for smaller entities that have limited access to resources. Therefore, the contribution of this research is to use infrared spectroscopy measurements as a new effective technique substituting the DGA method for fault diagnosis in insulating oil. The inception faults that were considered in this study were the electrical fault (discharges of high energy) and the thermal fault (300°C < Temperature < 700°C). Regarding that, two test cells were crafted especially for serving the simulation processes inside the laboratory for both types of inception faults. Subsequently, six samples of pure paraffinic mineral oil were taken to be degraded in the laboratory. Following that, all of them besides another sample that were not subjected to any kind of faults were taken to be examined by Fourier transform infrared (FTIR) spectroscopy to obtain an overview of the oil's behaviour in each fault case. After that, the FTIR analysis was initially verified utilising the DGA method. Then, for further affirmation, the dielectric dissipation factor (DDF) for all samples was measured. In the final analysis, the verification tests provide experimental evidence about the outperformance of this new optical technique in detecting the transformer's inception faults in addition to proving its potential for being a superior alternative to the well-known traditional diagnostic techniques.</p>\",\"PeriodicalId\":48649,\"journal\":{\"name\":\"High Voltage\",\"volume\":\"9 2\",\"pages\":\"319-335\"},\"PeriodicalIF\":4.4000,\"publicationDate\":\"2024-01-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/hve2.12405\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"High Voltage\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/hve2.12405\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"High Voltage","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/hve2.12405","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
A new technique for fault diagnosis in transformer insulating oil based on infrared spectroscopy measurements
Condition monitoring of the insulating system within power transformers has a massive importance according to the electrical utilities. Dissolved gas analysis (DGA) is frequently used for this purpose. However, DGA lacks the necessary level of accuracy to identify all equipment faults, particularly in their initial stages of degradation. Also, it does not have the capability for real-time monitoring and relies on manual sampling and laboratory testing, causing potential delays in fault identification. Additionally, the interpretation of DGA data necessitates specialised expertise, which may pose difficulties for smaller entities that have limited access to resources. Therefore, the contribution of this research is to use infrared spectroscopy measurements as a new effective technique substituting the DGA method for fault diagnosis in insulating oil. The inception faults that were considered in this study were the electrical fault (discharges of high energy) and the thermal fault (300°C < Temperature < 700°C). Regarding that, two test cells were crafted especially for serving the simulation processes inside the laboratory for both types of inception faults. Subsequently, six samples of pure paraffinic mineral oil were taken to be degraded in the laboratory. Following that, all of them besides another sample that were not subjected to any kind of faults were taken to be examined by Fourier transform infrared (FTIR) spectroscopy to obtain an overview of the oil's behaviour in each fault case. After that, the FTIR analysis was initially verified utilising the DGA method. Then, for further affirmation, the dielectric dissipation factor (DDF) for all samples was measured. In the final analysis, the verification tests provide experimental evidence about the outperformance of this new optical technique in detecting the transformer's inception faults in addition to proving its potential for being a superior alternative to the well-known traditional diagnostic techniques.
High VoltageEnergy-Energy Engineering and Power Technology
CiteScore
9.60
自引率
27.30%
发文量
97
审稿时长
21 weeks
期刊介绍:
High Voltage aims to attract original research papers and review articles. The scope covers high-voltage power engineering and high voltage applications, including experimental, computational (including simulation and modelling) and theoretical studies, which include:
Electrical Insulation
● Outdoor, indoor, solid, liquid and gas insulation
● Transient voltages and overvoltage protection
● Nano-dielectrics and new insulation materials
● Condition monitoring and maintenance
Discharge and plasmas, pulsed power
● Electrical discharge, plasma generation and applications
● Interactions of plasma with surfaces
● Pulsed power science and technology
High-field effects
● Computation, measurements of Intensive Electromagnetic Field
● Electromagnetic compatibility
● Biomedical effects
● Environmental effects and protection
High Voltage Engineering
● Design problems, testing and measuring techniques
● Equipment development and asset management
● Smart Grid, live line working
● AC/DC power electronics
● UHV power transmission
Special Issues. Call for papers:
Interface Charging Phenomena for Dielectric Materials - https://digital-library.theiet.org/files/HVE_CFP_ICP.pdf
Emerging Materials For High Voltage Applications - https://digital-library.theiet.org/files/HVE_CFP_EMHVA.pdf