Lucas M Ritschl, Carolina Classen, Paul Kilbertus, Julia Eufinger, Katharina Storck, Andreas M Fichter, Klaus-Dietrich Wolff, Florian D Grill
{"title":"使用三种不同 3D 摄影系统对鼻部进行三维成像的比较:一项观察研究。","authors":"Lucas M Ritschl, Carolina Classen, Paul Kilbertus, Julia Eufinger, Katharina Storck, Andreas M Fichter, Klaus-Dietrich Wolff, Florian D Grill","doi":"10.1186/s13005-024-00406-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>New 3D technologies for superficial soft tissue changes, especially in plastic and reconstructive surgical procedures, can improve the planning and documentation of facial surgeries. The purpose of this study was to compare and determine the applicability and feasibility of three different 3D-photography systems in clinical practice imaging the nose.</p><p><strong>Methods: </strong>A total of 16 healthy non-operated noses were included in this prospective study. A plaster model of each nose was produced, digitized, and converted to a .stl mesh (= ground truth model). Three-dimensional images of each nose were then taken using Artec Space Spider (gold standard), Planmeca ProFace®, and the Bellus3D Dental Pro application. All resulting .stl files were aligned to the ground truth model using MeshLab software, and the root mean square error (RMSE), mean surface distance (MSD), and Hausdorff distance (HD) were calculated.</p><p><strong>Results: </strong>The Artec Space Spider 3D-photography system showed significantly better results compared to the two other systems in regard to RMSE, MSD, and HD (each p < 0.001). There was no significant difference between Planmeca ProFace® and Bellus3D Dental Pro in terms of RMSE, MSD, and HD. Overall, all three camera systems showed a clinically acceptable deviation to the reference model (range: -1.23-1.57 mm).</p><p><strong>Conclusions: </strong>The three evaluated 3D-photography systems were suitable for nose imaging in the clinical routine. While Artec Space Spider showed the highest accuracy, the Bellus3D Dental Pro app may be the most feasible option for everyday clinical use due to its portability, ease of use, and low cost. This study presents three different systems, allowing readers to extrapolate to other systems when planning to introduce 3D photography in the clinical routine.</p>","PeriodicalId":12994,"journal":{"name":"Head & Face Medicine","volume":"20 1","pages":"7"},"PeriodicalIF":2.4000,"publicationDate":"2024-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10807178/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of three-dimensional imaging of the nose using three different 3D-photography systems: an observational study.\",\"authors\":\"Lucas M Ritschl, Carolina Classen, Paul Kilbertus, Julia Eufinger, Katharina Storck, Andreas M Fichter, Klaus-Dietrich Wolff, Florian D Grill\",\"doi\":\"10.1186/s13005-024-00406-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>New 3D technologies for superficial soft tissue changes, especially in plastic and reconstructive surgical procedures, can improve the planning and documentation of facial surgeries. The purpose of this study was to compare and determine the applicability and feasibility of three different 3D-photography systems in clinical practice imaging the nose.</p><p><strong>Methods: </strong>A total of 16 healthy non-operated noses were included in this prospective study. A plaster model of each nose was produced, digitized, and converted to a .stl mesh (= ground truth model). Three-dimensional images of each nose were then taken using Artec Space Spider (gold standard), Planmeca ProFace®, and the Bellus3D Dental Pro application. All resulting .stl files were aligned to the ground truth model using MeshLab software, and the root mean square error (RMSE), mean surface distance (MSD), and Hausdorff distance (HD) were calculated.</p><p><strong>Results: </strong>The Artec Space Spider 3D-photography system showed significantly better results compared to the two other systems in regard to RMSE, MSD, and HD (each p < 0.001). There was no significant difference between Planmeca ProFace® and Bellus3D Dental Pro in terms of RMSE, MSD, and HD. Overall, all three camera systems showed a clinically acceptable deviation to the reference model (range: -1.23-1.57 mm).</p><p><strong>Conclusions: </strong>The three evaluated 3D-photography systems were suitable for nose imaging in the clinical routine. While Artec Space Spider showed the highest accuracy, the Bellus3D Dental Pro app may be the most feasible option for everyday clinical use due to its portability, ease of use, and low cost. This study presents three different systems, allowing readers to extrapolate to other systems when planning to introduce 3D photography in the clinical routine.</p>\",\"PeriodicalId\":12994,\"journal\":{\"name\":\"Head & Face Medicine\",\"volume\":\"20 1\",\"pages\":\"7\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10807178/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Head & Face Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s13005-024-00406-4\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Head & Face Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13005-024-00406-4","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
背景:针对表层软组织变化,尤其是整形和重建外科手术中表层软组织变化的新三维技术可以改善面部手术的规划和记录。本研究的目的是比较并确定三种不同的三维摄影系统在鼻部成像临床实践中的适用性和可行性:方法:这项前瞻性研究共纳入了 16 个健康的非手术鼻子。每个鼻子都制作了石膏模型,将其数字化并转换成 .stl 网格(= 地面实况模型)。然后使用 Artec Space Spider(黄金标准)、Planmeca ProFace® 和 Bellus3D Dental Pro 应用程序拍摄每个鼻子的三维图像。使用 MeshLab 软件将所有生成的 .stl 文件与地面实况模型对齐,并计算均方根误差 (RMSE)、平均表面距离 (MSD) 和豪斯多夫距离 (HD):结果:Artec Space Spider 三维摄影系统在均方根误差、平均表面距离和豪斯多夫距离方面的结果明显优于其他两个系统(各 p 为结论):所评估的三种三维照相系统都适用于临床常规的鼻部成像。虽然 Artec Space Spider 显示出最高的精确度,但 Bellus3D Dental Pro 应用程序因其便携性、易用性和低成本,可能是日常临床使用中最可行的选择。本研究介绍了三种不同的系统,使读者在计划将三维摄影引入临床常规时,可以推断出其他系统。
Comparison of three-dimensional imaging of the nose using three different 3D-photography systems: an observational study.
Background: New 3D technologies for superficial soft tissue changes, especially in plastic and reconstructive surgical procedures, can improve the planning and documentation of facial surgeries. The purpose of this study was to compare and determine the applicability and feasibility of three different 3D-photography systems in clinical practice imaging the nose.
Methods: A total of 16 healthy non-operated noses were included in this prospective study. A plaster model of each nose was produced, digitized, and converted to a .stl mesh (= ground truth model). Three-dimensional images of each nose were then taken using Artec Space Spider (gold standard), Planmeca ProFace®, and the Bellus3D Dental Pro application. All resulting .stl files were aligned to the ground truth model using MeshLab software, and the root mean square error (RMSE), mean surface distance (MSD), and Hausdorff distance (HD) were calculated.
Results: The Artec Space Spider 3D-photography system showed significantly better results compared to the two other systems in regard to RMSE, MSD, and HD (each p < 0.001). There was no significant difference between Planmeca ProFace® and Bellus3D Dental Pro in terms of RMSE, MSD, and HD. Overall, all three camera systems showed a clinically acceptable deviation to the reference model (range: -1.23-1.57 mm).
Conclusions: The three evaluated 3D-photography systems were suitable for nose imaging in the clinical routine. While Artec Space Spider showed the highest accuracy, the Bellus3D Dental Pro app may be the most feasible option for everyday clinical use due to its portability, ease of use, and low cost. This study presents three different systems, allowing readers to extrapolate to other systems when planning to introduce 3D photography in the clinical routine.
期刊介绍:
Head & Face Medicine is a multidisciplinary open access journal that publishes basic and clinical research concerning all aspects of cranial, facial and oral conditions.
The journal covers all aspects of cranial, facial and oral diseases and their management. It has been designed as a multidisciplinary journal for clinicians and researchers involved in the diagnostic and therapeutic aspects of diseases which affect the human head and face. The journal is wide-ranging, covering the development, aetiology, epidemiology and therapy of head and face diseases to the basic science that underlies these diseases. Management of head and face diseases includes all aspects of surgical and non-surgical treatments including psychopharmacological therapies.