H S Cho, D Y Seo, D S Kim, J S Kang, Y U Kim, Y H Kwon, M S Kim
{"title":"无领骨水泥全髋关节置换术柄对植入物下沉影响的生物力学评估:对德国牧羊犬的尸体研究。","authors":"H S Cho, D Y Seo, D S Kim, J S Kang, Y U Kim, Y H Kwon, M S Kim","doi":"10.22099/IJVR.2023.47029.6770","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>With the increasing use of cementless total hip arthroplasty (THA), stem subsidence has emerged as one of the primary complications. Although electron beam melting (EBM)-manufactured stems have been demonstrated to prevent subsidence, there has been limited investigation into the comparative biomechanical impact of collarless and collared EBM cementless stems on stem subsidence in veterinary medicine.</p><p><strong>Aims: </strong>This study aimed to compare the stem implant resistance and failure mechanical properties between collarless and collared EBM-manufactured stems.</p><p><strong>Methods: </strong>Seven pairs of femurs were harvested from canine cadavers. In each pair of femurs, the left femur was implanted with a collarless, and the right femur with a same-sized collared cementless stem. Specimen constructs were mounted to the loading frame of a testing machine and load was transferred to the femoral stem parallel to the longitudinal axis of the femur until the stem subsided 5 mm. Load and stem displacement data acquired during the tests were used to generate load-displacement curves and obtain stiffness, yield, and failure data for each specimen construct. Yield and failure energies were calculated as the areas under the load-displacement curves to the respective points. The effects of implant type and load during subsidence were analyzed using paired t-tests.</p><p><strong>Results: </strong>The yield and failure loads for the collared stems were approximately 40% greater than for the collarless stems (156.39 ± 43.63 kgf vs. 112.01 ± 59.83 kgf, P<0.05).</p><p><strong>Conclusion: </strong>This study supported the advantages of collared EBM stems, including subsidence prevention and better initial stability for early osteointegration.</p>","PeriodicalId":14629,"journal":{"name":"Iranian journal of veterinary research","volume":"24 3","pages":"242-246"},"PeriodicalIF":0.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10804427/pdf/","citationCount":"0","resultStr":"{\"title\":\"Biomechanical evaluation of the impact of collared cementless total hip arthroplasty stems on implant subsidence: a cadaveric study in German Shepherd.\",\"authors\":\"H S Cho, D Y Seo, D S Kim, J S Kang, Y U Kim, Y H Kwon, M S Kim\",\"doi\":\"10.22099/IJVR.2023.47029.6770\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>With the increasing use of cementless total hip arthroplasty (THA), stem subsidence has emerged as one of the primary complications. Although electron beam melting (EBM)-manufactured stems have been demonstrated to prevent subsidence, there has been limited investigation into the comparative biomechanical impact of collarless and collared EBM cementless stems on stem subsidence in veterinary medicine.</p><p><strong>Aims: </strong>This study aimed to compare the stem implant resistance and failure mechanical properties between collarless and collared EBM-manufactured stems.</p><p><strong>Methods: </strong>Seven pairs of femurs were harvested from canine cadavers. In each pair of femurs, the left femur was implanted with a collarless, and the right femur with a same-sized collared cementless stem. Specimen constructs were mounted to the loading frame of a testing machine and load was transferred to the femoral stem parallel to the longitudinal axis of the femur until the stem subsided 5 mm. Load and stem displacement data acquired during the tests were used to generate load-displacement curves and obtain stiffness, yield, and failure data for each specimen construct. Yield and failure energies were calculated as the areas under the load-displacement curves to the respective points. The effects of implant type and load during subsidence were analyzed using paired t-tests.</p><p><strong>Results: </strong>The yield and failure loads for the collared stems were approximately 40% greater than for the collarless stems (156.39 ± 43.63 kgf vs. 112.01 ± 59.83 kgf, P<0.05).</p><p><strong>Conclusion: </strong>This study supported the advantages of collared EBM stems, including subsidence prevention and better initial stability for early osteointegration.</p>\",\"PeriodicalId\":14629,\"journal\":{\"name\":\"Iranian journal of veterinary research\",\"volume\":\"24 3\",\"pages\":\"242-246\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10804427/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian journal of veterinary research\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.22099/IJVR.2023.47029.6770\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian journal of veterinary research","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.22099/IJVR.2023.47029.6770","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
背景:随着无骨水泥全髋关节置换术(THA)的使用越来越多,柄下沉已成为主要并发症之一。虽然电子束熔化(EBM)制造的柄已被证明可防止下沉,但在兽医领域,对无领和有领EBM无骨水泥柄对柄下沉的生物力学影响的比较研究还很有限:方法:从犬尸体上采集七对股骨。在每对股骨中,左侧股骨植入无领骨水泥柄,右侧股骨植入相同大小的无领骨水泥柄。将样本结构安装到试验机的加载架上,然后将载荷平行于股骨纵轴传递到股骨柄上,直到股骨柄下沉5毫米。测试期间获得的载荷和股骨干位移数据用于生成载荷-位移曲线,并获得每个试样结构的刚度、屈服和破坏数据。屈服能量和破坏能量是根据载荷-位移曲线到相应点的面积计算得出的。使用配对 t 检验分析了种植体类型和下沉过程中载荷的影响:结果:有领种植体的屈服和失效载荷比无领种植体高出约 40%(156.39 ± 43.63 kgf vs 112.01 ± 59.83 kgf,PC):这项研究证实了有领 EBM 骨茎的优点,包括防止下沉和更好的初期稳定性,以利于早期骨整合。
Biomechanical evaluation of the impact of collared cementless total hip arthroplasty stems on implant subsidence: a cadaveric study in German Shepherd.
Background: With the increasing use of cementless total hip arthroplasty (THA), stem subsidence has emerged as one of the primary complications. Although electron beam melting (EBM)-manufactured stems have been demonstrated to prevent subsidence, there has been limited investigation into the comparative biomechanical impact of collarless and collared EBM cementless stems on stem subsidence in veterinary medicine.
Aims: This study aimed to compare the stem implant resistance and failure mechanical properties between collarless and collared EBM-manufactured stems.
Methods: Seven pairs of femurs were harvested from canine cadavers. In each pair of femurs, the left femur was implanted with a collarless, and the right femur with a same-sized collared cementless stem. Specimen constructs were mounted to the loading frame of a testing machine and load was transferred to the femoral stem parallel to the longitudinal axis of the femur until the stem subsided 5 mm. Load and stem displacement data acquired during the tests were used to generate load-displacement curves and obtain stiffness, yield, and failure data for each specimen construct. Yield and failure energies were calculated as the areas under the load-displacement curves to the respective points. The effects of implant type and load during subsidence were analyzed using paired t-tests.
Results: The yield and failure loads for the collared stems were approximately 40% greater than for the collarless stems (156.39 ± 43.63 kgf vs. 112.01 ± 59.83 kgf, P<0.05).
Conclusion: This study supported the advantages of collared EBM stems, including subsidence prevention and better initial stability for early osteointegration.
期刊介绍:
The Iranian Journal of Veterinary Research(IJVR) is published quarterly in 4 issues. The aims of this journal are to improve and expand knowledge in all veterinary fields. It is an international journal indexed by the Thomson Institute for Scientific Information (ISI), Elsevier, Scopus, CAB International, Veterinary Bulletin and several other international databases. Research papers and reports on a wide range of veterinary topics are published in the journal after being evaluated by expert reviewers.The Editor-in-Chief is responsible for the editorial content of the journal—including peer-reviewed manuscripts—and the timing of its publication.