Jialu Wang, Anqi Song, Molian Tang, Yi Xiang, Yiquan Zhou, Zhiqi Chen, David Heber, Qingya Tang, Renying Xu
{"title":"商用 3DO 人体扫描仪测量中国成年人超重和肥胖症患者身体成分的适用性:基于减肥临床试验的二次分析。","authors":"Jialu Wang, Anqi Song, Molian Tang, Yi Xiang, Yiquan Zhou, Zhiqi Chen, David Heber, Qingya Tang, Renying Xu","doi":"10.1080/15502783.2024.2307963","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A commercial three-dimensional optical (3DO) scanning system was reported to be used in body composition assessment. However, the applicability in Chinese adults has yet to be well-studied.</p><p><strong>Methods: </strong>This secondary analysis was based on a 16-week weight-loss clinical trial with an optional extension to 24 weeks. Waist and hip circumference and body composition were measured by 3DO scanning at each follow-up visit during the study. Bioelectrical impedance analysis (BIA) was also performed to confirm the reliability of 3DO scanning at each visit. We used Lin's concordance correlation coefficients (CCC) to evaluate the correlation between the two methods above-mentioned. Bland-Altman analysis was also performed to evaluate the agreement and potential bias between different methods.</p><p><strong>Results: </strong>A total number of 70 Chinese adults overweight and obese (23 men and 47 women, aged 31.8 ± 5.8 years) were included in the analysis, which resulted in 350 3DO scans and corresponding 350 BIA measurements. The percent body fat, fat mass, and fat-free mass were 33.9 ± 5.4%, 26.7 ± 4.6 kg, and 50.3 ± 8.7 kg before the trial by 3DO scanning. And they were 30.5 ± 5.8%, 22.5 ± 4.7 kg, and 49.4 ± 8.3 kg after 16 weeks of the trial. Compared with BIA, 3DO scanning performed best in the assessment of fat-free mass (CCC = 0.89, 95%CI: 0.86, 0.90), then followed by fat mass (CCC = 0.76, 95%CI: 0.71, 0.80) and percent body fat (CCC = 0.70, 95%CI: 0.64, 0.75). Subgroup analysis showed that 3DO scanning and BIA correlated better in women than that in men, and correlated better in measuring fat-free mass in participants with larger body weight (BMI ≥28.0 kg/m<sup>2</sup>) than those with smaller body weight (<28.0 kg/m<sup>2</sup>).</p><p><strong>Conclusions: </strong>3DO scanning is an effective technology to monitor changes in body composition in Chinese adults overweight and obese. However its accuracy and reliability in different ethnicities needs further exploration.</p>","PeriodicalId":17400,"journal":{"name":"Journal of the International Society of Sports Nutrition","volume":"21 1","pages":"2307963"},"PeriodicalIF":4.5000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10810617/pdf/","citationCount":"0","resultStr":"{\"title\":\"The applicability of a commercial 3DO body scanner in measuring body composition in Chinese adults with overweight and obesity: a secondary analysis based on a weight-loss clinical trial.\",\"authors\":\"Jialu Wang, Anqi Song, Molian Tang, Yi Xiang, Yiquan Zhou, Zhiqi Chen, David Heber, Qingya Tang, Renying Xu\",\"doi\":\"10.1080/15502783.2024.2307963\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>A commercial three-dimensional optical (3DO) scanning system was reported to be used in body composition assessment. However, the applicability in Chinese adults has yet to be well-studied.</p><p><strong>Methods: </strong>This secondary analysis was based on a 16-week weight-loss clinical trial with an optional extension to 24 weeks. Waist and hip circumference and body composition were measured by 3DO scanning at each follow-up visit during the study. Bioelectrical impedance analysis (BIA) was also performed to confirm the reliability of 3DO scanning at each visit. We used Lin's concordance correlation coefficients (CCC) to evaluate the correlation between the two methods above-mentioned. Bland-Altman analysis was also performed to evaluate the agreement and potential bias between different methods.</p><p><strong>Results: </strong>A total number of 70 Chinese adults overweight and obese (23 men and 47 women, aged 31.8 ± 5.8 years) were included in the analysis, which resulted in 350 3DO scans and corresponding 350 BIA measurements. The percent body fat, fat mass, and fat-free mass were 33.9 ± 5.4%, 26.7 ± 4.6 kg, and 50.3 ± 8.7 kg before the trial by 3DO scanning. And they were 30.5 ± 5.8%, 22.5 ± 4.7 kg, and 49.4 ± 8.3 kg after 16 weeks of the trial. Compared with BIA, 3DO scanning performed best in the assessment of fat-free mass (CCC = 0.89, 95%CI: 0.86, 0.90), then followed by fat mass (CCC = 0.76, 95%CI: 0.71, 0.80) and percent body fat (CCC = 0.70, 95%CI: 0.64, 0.75). Subgroup analysis showed that 3DO scanning and BIA correlated better in women than that in men, and correlated better in measuring fat-free mass in participants with larger body weight (BMI ≥28.0 kg/m<sup>2</sup>) than those with smaller body weight (<28.0 kg/m<sup>2</sup>).</p><p><strong>Conclusions: </strong>3DO scanning is an effective technology to monitor changes in body composition in Chinese adults overweight and obese. However its accuracy and reliability in different ethnicities needs further exploration.</p>\",\"PeriodicalId\":17400,\"journal\":{\"name\":\"Journal of the International Society of Sports Nutrition\",\"volume\":\"21 1\",\"pages\":\"2307963\"},\"PeriodicalIF\":4.5000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10810617/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the International Society of Sports Nutrition\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/15502783.2024.2307963\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"NUTRITION & DIETETICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the International Society of Sports Nutrition","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/15502783.2024.2307963","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"NUTRITION & DIETETICS","Score":null,"Total":0}
The applicability of a commercial 3DO body scanner in measuring body composition in Chinese adults with overweight and obesity: a secondary analysis based on a weight-loss clinical trial.
Background: A commercial three-dimensional optical (3DO) scanning system was reported to be used in body composition assessment. However, the applicability in Chinese adults has yet to be well-studied.
Methods: This secondary analysis was based on a 16-week weight-loss clinical trial with an optional extension to 24 weeks. Waist and hip circumference and body composition were measured by 3DO scanning at each follow-up visit during the study. Bioelectrical impedance analysis (BIA) was also performed to confirm the reliability of 3DO scanning at each visit. We used Lin's concordance correlation coefficients (CCC) to evaluate the correlation between the two methods above-mentioned. Bland-Altman analysis was also performed to evaluate the agreement and potential bias between different methods.
Results: A total number of 70 Chinese adults overweight and obese (23 men and 47 women, aged 31.8 ± 5.8 years) were included in the analysis, which resulted in 350 3DO scans and corresponding 350 BIA measurements. The percent body fat, fat mass, and fat-free mass were 33.9 ± 5.4%, 26.7 ± 4.6 kg, and 50.3 ± 8.7 kg before the trial by 3DO scanning. And they were 30.5 ± 5.8%, 22.5 ± 4.7 kg, and 49.4 ± 8.3 kg after 16 weeks of the trial. Compared with BIA, 3DO scanning performed best in the assessment of fat-free mass (CCC = 0.89, 95%CI: 0.86, 0.90), then followed by fat mass (CCC = 0.76, 95%CI: 0.71, 0.80) and percent body fat (CCC = 0.70, 95%CI: 0.64, 0.75). Subgroup analysis showed that 3DO scanning and BIA correlated better in women than that in men, and correlated better in measuring fat-free mass in participants with larger body weight (BMI ≥28.0 kg/m2) than those with smaller body weight (<28.0 kg/m2).
Conclusions: 3DO scanning is an effective technology to monitor changes in body composition in Chinese adults overweight and obese. However its accuracy and reliability in different ethnicities needs further exploration.
期刊介绍:
Journal of the International Society of Sports Nutrition (JISSN) focuses on the acute and chronic effects of sports nutrition and supplementation strategies on body composition, physical performance and metabolism. JISSN is aimed at researchers and sport enthusiasts focused on delivering knowledge on exercise and nutrition on health, disease, rehabilitation, training, and performance. The journal provides a platform on which readers can determine nutritional strategies that may enhance exercise and/or training adaptations leading to improved health and performance.