{"title":"卵圆孔解剖特征与卵圆孔关闭术后残留分流之间的关系","authors":"Rie Nakayama, Yoichi Takaya, Teiji Akagi, Rika Takemoto, Madoka Haruna, Mitsutaka Nakashima, Takashi Miki, Koji Nakagawa, Norihisa Toh, Kazufumi Nakamura","doi":"10.1007/s12928-023-00979-y","DOIUrl":null,"url":null,"abstract":"<p><p>Transcatheter closure of patent foramen ovale (PFO) is an effective strategy for preventing recurrence of paradoxical embolism. However, PFO closure is often associated with residual shunt, which is a risk of recurrent stroke. This study aimed to evaluate the relationship between the anatomical features of PFO and residual shunt. The degree of residual shunt and its relationship with the anatomical features of PFO were evaluated in 106 patients who underwent PFO closure at our institution between March 2011 and January 2022 and in whom contrast transthoracic echocardiography was performed 1 year later. The mean PFO tunnel length was 9.3 ± 3.6 mm and the mean PFO height was 3.2 ± 2.2 mm. Atrial septal aneurysm (ASA) was found in 37 patients. After PFO closure, residual shunt was observed in 28 patients (grade 1, n = 8; grade 2, n = 16; grade 3, n = 3; grade 4, n = 1). Univariate logistic analysis identified ASA to be associated with residual shunt (odds ratio 2.78, 95% confidence interval 1.14 to 6.79; p = 0.024). There was no association of residual shunt with the size of the PFO, the length of PFO tunnel, or the size of the device used for closure. Two of four patients with a large residual shunt of grade 3 or grade 4 were found to have device size mismatch. Residual shunt after PFO closure was observed in a quarter of patients and was related to the presence of ASA. A few patients had a large residual shunt due to the device size mismatch.</p>","PeriodicalId":9439,"journal":{"name":"Cardiovascular Intervention and Therapeutics","volume":" ","pages":"200-206"},"PeriodicalIF":3.1000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Relationship between patent foramen ovale anatomical features and residual shunt after patent foramen ovale closure.\",\"authors\":\"Rie Nakayama, Yoichi Takaya, Teiji Akagi, Rika Takemoto, Madoka Haruna, Mitsutaka Nakashima, Takashi Miki, Koji Nakagawa, Norihisa Toh, Kazufumi Nakamura\",\"doi\":\"10.1007/s12928-023-00979-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Transcatheter closure of patent foramen ovale (PFO) is an effective strategy for preventing recurrence of paradoxical embolism. However, PFO closure is often associated with residual shunt, which is a risk of recurrent stroke. This study aimed to evaluate the relationship between the anatomical features of PFO and residual shunt. The degree of residual shunt and its relationship with the anatomical features of PFO were evaluated in 106 patients who underwent PFO closure at our institution between March 2011 and January 2022 and in whom contrast transthoracic echocardiography was performed 1 year later. The mean PFO tunnel length was 9.3 ± 3.6 mm and the mean PFO height was 3.2 ± 2.2 mm. Atrial septal aneurysm (ASA) was found in 37 patients. After PFO closure, residual shunt was observed in 28 patients (grade 1, n = 8; grade 2, n = 16; grade 3, n = 3; grade 4, n = 1). Univariate logistic analysis identified ASA to be associated with residual shunt (odds ratio 2.78, 95% confidence interval 1.14 to 6.79; p = 0.024). There was no association of residual shunt with the size of the PFO, the length of PFO tunnel, or the size of the device used for closure. Two of four patients with a large residual shunt of grade 3 or grade 4 were found to have device size mismatch. Residual shunt after PFO closure was observed in a quarter of patients and was related to the presence of ASA. A few patients had a large residual shunt due to the device size mismatch.</p>\",\"PeriodicalId\":9439,\"journal\":{\"name\":\"Cardiovascular Intervention and Therapeutics\",\"volume\":\" \",\"pages\":\"200-206\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Intervention and Therapeutics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s12928-023-00979-y\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Intervention and Therapeutics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12928-023-00979-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/24 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

经导管闭合卵圆孔(PFO)是预防矛盾性栓塞复发的有效策略。然而,PFO 关闭术往往与残余分流有关,而残余分流是中风复发的风险之一。本研究旨在评估 PFO 的解剖特征与残余分流之间的关系。研究评估了 2011 年 3 月至 2022 年 1 月期间在我院接受 PFO 关闭术的 106 例患者的残余分流程度及其与 PFO 解剖特征之间的关系,并在 1 年后对这些患者进行了对比经胸超声心动图检查。平均 PFO 通道长度为 9.3 ± 3.6 毫米,平均 PFO 高度为 3.2 ± 2.2 毫米。37名患者发现了房间隔动脉瘤(ASA)。PFO 关闭后,28 名患者观察到残余分流(1 级,n = 8;2 级,n = 16;3 级,n = 3;4 级,n = 1)。单变量逻辑分析确定 ASA 与残余分流有关(几率比 2.78,95% 置信区间 1.14 至 6.79;P = 0.024)。残余分流与 PFO 的大小、PFO 通道的长度或用于关闭的装置的大小没有关系。在四名残余分流较大的 3 级或 4 级患者中,有两名患者的装置尺寸不匹配。四分之一的患者在关闭 PFO 后出现残余分流,这与 ASA 的存在有关。少数患者因装置尺寸不匹配而出现大量残余分流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Relationship between patent foramen ovale anatomical features and residual shunt after patent foramen ovale closure.

Transcatheter closure of patent foramen ovale (PFO) is an effective strategy for preventing recurrence of paradoxical embolism. However, PFO closure is often associated with residual shunt, which is a risk of recurrent stroke. This study aimed to evaluate the relationship between the anatomical features of PFO and residual shunt. The degree of residual shunt and its relationship with the anatomical features of PFO were evaluated in 106 patients who underwent PFO closure at our institution between March 2011 and January 2022 and in whom contrast transthoracic echocardiography was performed 1 year later. The mean PFO tunnel length was 9.3 ± 3.6 mm and the mean PFO height was 3.2 ± 2.2 mm. Atrial septal aneurysm (ASA) was found in 37 patients. After PFO closure, residual shunt was observed in 28 patients (grade 1, n = 8; grade 2, n = 16; grade 3, n = 3; grade 4, n = 1). Univariate logistic analysis identified ASA to be associated with residual shunt (odds ratio 2.78, 95% confidence interval 1.14 to 6.79; p = 0.024). There was no association of residual shunt with the size of the PFO, the length of PFO tunnel, or the size of the device used for closure. Two of four patients with a large residual shunt of grade 3 or grade 4 were found to have device size mismatch. Residual shunt after PFO closure was observed in a quarter of patients and was related to the presence of ASA. A few patients had a large residual shunt due to the device size mismatch.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cardiovascular Intervention and Therapeutics
Cardiovascular Intervention and Therapeutics CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
6.30
自引率
12.50%
发文量
68
期刊介绍: Cardiovascular Intervention and Therapeutics (CVIT) is an international journal covering the field of cardiovascular disease and includes cardiac (coronary and noncoronary) and peripheral interventions and therapeutics. Articles are subject to peer review and complete editorial evaluation prior to any decision regarding acceptability. CVIT is an official journal of The Japanese Association of Cardiovascular Intervention and Therapeutics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信