Shahnam Valizadeh Shahbazlou, S. Vandghanooni, Bahareh Dabirmanesh, M. Eskandani, S. Hasannia
{"title":"通过表面等离子体共振对 MUC16 抗原/氨端肽相互作用进行超灵敏定量:动力学和热力学研究","authors":"Shahnam Valizadeh Shahbazlou, S. Vandghanooni, Bahareh Dabirmanesh, M. Eskandani, S. Hasannia","doi":"10.34172/apb.2024.028","DOIUrl":null,"url":null,"abstract":"MUC16 is a commonly employed biomarker in the identification and prognosis of ovarian cancer (OC). Precise measurement of MUC16 levels is essential for the accurate diagnosis, prediction, and management of OC. This research seeks to introduce a new surface plasmon resonance (SPR) biosensor design that utilizes aptamer-based technology to enable the sensitive and real-time detection of MUC16. In this study, the sensor chip was immobilized with an anti-MUC16 aptamer (Ap) by utilizing 11-mercaptoundecanoic acid (MUA) as a linker to attach the amine-terminated Ap to the chip using EDC/NHS chemistry. The results indicated that the newly created aptasensor had a detection limit of 0.03 U mL-1 for MUC16 concentration, with a linear range of 0.09 to 0.027 U mL-1. The findings demonstrate good precision and accuracy (<15%) for each MUC16 concentration, with recoveries ranging from 93% to 96%. Additionally, the aptasensor exhibited high selectivity, good repeatability, stability, and applicability in real human serum samples, indicating its potential as a valuable tool for the diagnosis and treatment of ovarian cancer.","PeriodicalId":7256,"journal":{"name":"Advanced pharmaceutical bulletin","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasensitive Quantification of MUC16 Antigen/Amine-terminated Aptamer Interaction by Surface Plasmon Resonance: Kinetic and Thermodynamic Studies\",\"authors\":\"Shahnam Valizadeh Shahbazlou, S. Vandghanooni, Bahareh Dabirmanesh, M. Eskandani, S. Hasannia\",\"doi\":\"10.34172/apb.2024.028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"MUC16 is a commonly employed biomarker in the identification and prognosis of ovarian cancer (OC). Precise measurement of MUC16 levels is essential for the accurate diagnosis, prediction, and management of OC. This research seeks to introduce a new surface plasmon resonance (SPR) biosensor design that utilizes aptamer-based technology to enable the sensitive and real-time detection of MUC16. In this study, the sensor chip was immobilized with an anti-MUC16 aptamer (Ap) by utilizing 11-mercaptoundecanoic acid (MUA) as a linker to attach the amine-terminated Ap to the chip using EDC/NHS chemistry. The results indicated that the newly created aptasensor had a detection limit of 0.03 U mL-1 for MUC16 concentration, with a linear range of 0.09 to 0.027 U mL-1. The findings demonstrate good precision and accuracy (<15%) for each MUC16 concentration, with recoveries ranging from 93% to 96%. Additionally, the aptasensor exhibited high selectivity, good repeatability, stability, and applicability in real human serum samples, indicating its potential as a valuable tool for the diagnosis and treatment of ovarian cancer.\",\"PeriodicalId\":7256,\"journal\":{\"name\":\"Advanced pharmaceutical bulletin\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-01-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced pharmaceutical bulletin\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34172/apb.2024.028\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced pharmaceutical bulletin","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/apb.2024.028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
摘要
MUC16是卵巢癌(OC)鉴别和预后常用的生物标志物。精确测量 MUC16 水平对于准确诊断、预测和管理卵巢癌至关重要。本研究试图引入一种新的表面等离子体共振(SPR)生物传感器设计,利用基于适配体的技术实现对 MUC16 的灵敏和实时检测。在这项研究中,利用 11-巯基十酸酐(MUA)作为连接剂,通过 EDC/NHS 化学方法将氨基末端的 Ap 连接到芯片上,从而用抗 MUC16 的适配体(Ap)固定传感器芯片。结果表明,新创建的灵敏传感器对 MUC16 浓度的检测限为 0.03 U mL-1,线性范围为 0.09 至 0.027 U mL-1。研究结果表明,每种浓度的 MUC16 都具有良好的精密度和准确度(<15%),回收率在 93% 至 96% 之间。此外,该灵敏传感器在真实人体血清样本中表现出高选择性、良好的可重复性、稳定性和适用性,表明它有望成为诊断和治疗卵巢癌的重要工具。
Ultrasensitive Quantification of MUC16 Antigen/Amine-terminated Aptamer Interaction by Surface Plasmon Resonance: Kinetic and Thermodynamic Studies
MUC16 is a commonly employed biomarker in the identification and prognosis of ovarian cancer (OC). Precise measurement of MUC16 levels is essential for the accurate diagnosis, prediction, and management of OC. This research seeks to introduce a new surface plasmon resonance (SPR) biosensor design that utilizes aptamer-based technology to enable the sensitive and real-time detection of MUC16. In this study, the sensor chip was immobilized with an anti-MUC16 aptamer (Ap) by utilizing 11-mercaptoundecanoic acid (MUA) as a linker to attach the amine-terminated Ap to the chip using EDC/NHS chemistry. The results indicated that the newly created aptasensor had a detection limit of 0.03 U mL-1 for MUC16 concentration, with a linear range of 0.09 to 0.027 U mL-1. The findings demonstrate good precision and accuracy (<15%) for each MUC16 concentration, with recoveries ranging from 93% to 96%. Additionally, the aptasensor exhibited high selectivity, good repeatability, stability, and applicability in real human serum samples, indicating its potential as a valuable tool for the diagnosis and treatment of ovarian cancer.