Farnoush Fotovat, Samaneh Abbasi, Saeed Nikanjam, Behnaz Alafchi, Mandana Baghiat
{"title":"各种消毒剂对热固性和 3D 打印丙烯酸树脂表面粗糙度和颜色稳定性的影响。","authors":"Farnoush Fotovat, Samaneh Abbasi, Saeed Nikanjam, Behnaz Alafchi, Mandana Baghiat","doi":"10.4081/ejtm.2024.11701","DOIUrl":null,"url":null,"abstract":"<p><p>Denture cleansers are extensively utilized to inhibit the colonization of various Candida species. Currently, additive technology in denture fabrication has become more prevalent. This study aims to assess the impact of disinfectants on the surface roughness and color stability of distinct denture bases. Disc-shaped samples (N=66) were exposed to three different disinfectants: 0.5% sodium hypochlorite, 1% hydrogen peroxide, and 2% chlorhexidine. The samples underwent evaluation via spectrophotometry and profilometry, respectively. Data analysis was conducted utilizing analysis of variance (ANOVA) (p < 0.05). Within the heat-cured group, sodium hypochlorite resulted in the most notable change in surface roughness (0.2 μm), while chlorhexidine exhibited the least impact (0.001 μm), showing a significant difference (p <0.008). The color change (ΔE) for 3D-printed samples immersed in all disinfectants was higher compared to heat-cured samples. Among the heat-cured samples, chlorhexidine induced the highest ΔE (2.76), while sodium hypochlorite resulted in the lowest (ΔE = 1.44), and this difference was statistically significant (p <0.008). Chlorhexidine caused the most significant color alteration among the solutions, while sodium hypochlorite induced the most considerable changes in surface roughness.</p>","PeriodicalId":46459,"journal":{"name":"European Journal of Translational Myology","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11017172/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effects of various disinfectants on surface roughness and color stability of thermoset and 3D-printed acrylic resin.\",\"authors\":\"Farnoush Fotovat, Samaneh Abbasi, Saeed Nikanjam, Behnaz Alafchi, Mandana Baghiat\",\"doi\":\"10.4081/ejtm.2024.11701\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Denture cleansers are extensively utilized to inhibit the colonization of various Candida species. Currently, additive technology in denture fabrication has become more prevalent. This study aims to assess the impact of disinfectants on the surface roughness and color stability of distinct denture bases. Disc-shaped samples (N=66) were exposed to three different disinfectants: 0.5% sodium hypochlorite, 1% hydrogen peroxide, and 2% chlorhexidine. The samples underwent evaluation via spectrophotometry and profilometry, respectively. Data analysis was conducted utilizing analysis of variance (ANOVA) (p < 0.05). Within the heat-cured group, sodium hypochlorite resulted in the most notable change in surface roughness (0.2 μm), while chlorhexidine exhibited the least impact (0.001 μm), showing a significant difference (p <0.008). The color change (ΔE) for 3D-printed samples immersed in all disinfectants was higher compared to heat-cured samples. Among the heat-cured samples, chlorhexidine induced the highest ΔE (2.76), while sodium hypochlorite resulted in the lowest (ΔE = 1.44), and this difference was statistically significant (p <0.008). Chlorhexidine caused the most significant color alteration among the solutions, while sodium hypochlorite induced the most considerable changes in surface roughness.</p>\",\"PeriodicalId\":46459,\"journal\":{\"name\":\"European Journal of Translational Myology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-01-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11017172/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Translational Myology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4081/ejtm.2024.11701\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Translational Myology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/ejtm.2024.11701","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

义齿清洁剂被广泛用于抑制各种念珠菌的定植。目前,添加剂技术在义齿制作中越来越普遍。本研究旨在评估消毒剂对不同义齿基托表面粗糙度和颜色稳定性的影响。圆盘状样品(N=66)暴露于三种不同的消毒剂中:0.5% 次氯酸钠、1% 过氧化氢和 2% 洗必泰。样品分别通过分光光度法和轮廓测定法进行评估。数据分析采用方差分析法(P < 0.05)。在热固化组中,次氯酸钠对表面粗糙度的影响最大(0.2 μm),而洗必泰对表面粗糙度的影响最小(0.001 μm),两者差异显著(p<0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of various disinfectants on surface roughness and color stability of thermoset and 3D-printed acrylic resin.

Denture cleansers are extensively utilized to inhibit the colonization of various Candida species. Currently, additive technology in denture fabrication has become more prevalent. This study aims to assess the impact of disinfectants on the surface roughness and color stability of distinct denture bases. Disc-shaped samples (N=66) were exposed to three different disinfectants: 0.5% sodium hypochlorite, 1% hydrogen peroxide, and 2% chlorhexidine. The samples underwent evaluation via spectrophotometry and profilometry, respectively. Data analysis was conducted utilizing analysis of variance (ANOVA) (p < 0.05). Within the heat-cured group, sodium hypochlorite resulted in the most notable change in surface roughness (0.2 μm), while chlorhexidine exhibited the least impact (0.001 μm), showing a significant difference (p <0.008). The color change (ΔE) for 3D-printed samples immersed in all disinfectants was higher compared to heat-cured samples. Among the heat-cured samples, chlorhexidine induced the highest ΔE (2.76), while sodium hypochlorite resulted in the lowest (ΔE = 1.44), and this difference was statistically significant (p <0.008). Chlorhexidine caused the most significant color alteration among the solutions, while sodium hypochlorite induced the most considerable changes in surface roughness.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of Translational Myology
European Journal of Translational Myology MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
3.30
自引率
27.30%
发文量
74
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信