{"title":"利用吞咽过程中的二维侧面积测量预测咽部三维体积","authors":"Howell Henrian G Bayona, Yoko Inamoto, Eichii Saitoh, Keiko Aihara, Masanao Kobayashi, Yohei Otaka","doi":"10.1007/s00455-023-10659-x","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the validity of pharyngeal 2D area measurements acquired from the lateral view for predicting the actual 3D volume in healthy adults during swallowing. Seventy-five healthy adults (39 females, 36 males; mean age 51.3 years) were examined using 320-row area detector computed tomography (320-ADCT). All participants swallowed a 10 mL honey-thick barium bolus upon command while seated in a 45° semi-reclining position. Multi-planar reconstruction images and dynamic 3D-CT images were obtained using Aquilion ONE software. Pharyngeal 2D area and 3D volume measurements were taken before swallowing and at the frame depicting maximum pharyngeal constriction. Pharyngeal volume before swallowing (PVhold) was accurately predicted by 2D area (R<sup>2</sup> = 0.816). Adding height and sex to the model increased R<sup>2</sup> to 0.836. Regarding pharyngeal volume during maximum constriction (PVmax), 2D area also exhibited acceptable predictive power (R<sup>2</sup> = 0.777). However, analysis of statistical residuals and outliers revealed a greater tendency for prediction errors when there is less complete constriction of the pharynx as well as asymmetry in bolus flow or movement. Findings highlight the importance of routinely incorporating anterior-posterior views during VFSS exams. Future work is needed to determine clinical utility of pharyngeal volume measurements derived from 320-ADCT.</p>","PeriodicalId":11508,"journal":{"name":"Dysphagia","volume":" ","pages":"783-796"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Prediction of Pharyngeal 3D Volume Using 2D Lateral Area Measurements During Swallowing.\",\"authors\":\"Howell Henrian G Bayona, Yoko Inamoto, Eichii Saitoh, Keiko Aihara, Masanao Kobayashi, Yohei Otaka\",\"doi\":\"10.1007/s00455-023-10659-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study evaluated the validity of pharyngeal 2D area measurements acquired from the lateral view for predicting the actual 3D volume in healthy adults during swallowing. Seventy-five healthy adults (39 females, 36 males; mean age 51.3 years) were examined using 320-row area detector computed tomography (320-ADCT). All participants swallowed a 10 mL honey-thick barium bolus upon command while seated in a 45° semi-reclining position. Multi-planar reconstruction images and dynamic 3D-CT images were obtained using Aquilion ONE software. Pharyngeal 2D area and 3D volume measurements were taken before swallowing and at the frame depicting maximum pharyngeal constriction. Pharyngeal volume before swallowing (PVhold) was accurately predicted by 2D area (R<sup>2</sup> = 0.816). Adding height and sex to the model increased R<sup>2</sup> to 0.836. Regarding pharyngeal volume during maximum constriction (PVmax), 2D area also exhibited acceptable predictive power (R<sup>2</sup> = 0.777). However, analysis of statistical residuals and outliers revealed a greater tendency for prediction errors when there is less complete constriction of the pharynx as well as asymmetry in bolus flow or movement. Findings highlight the importance of routinely incorporating anterior-posterior views during VFSS exams. Future work is needed to determine clinical utility of pharyngeal volume measurements derived from 320-ADCT.</p>\",\"PeriodicalId\":11508,\"journal\":{\"name\":\"Dysphagia\",\"volume\":\" \",\"pages\":\"783-796\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dysphagia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00455-023-10659-x\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dysphagia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00455-023-10659-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
Prediction of Pharyngeal 3D Volume Using 2D Lateral Area Measurements During Swallowing.
This study evaluated the validity of pharyngeal 2D area measurements acquired from the lateral view for predicting the actual 3D volume in healthy adults during swallowing. Seventy-five healthy adults (39 females, 36 males; mean age 51.3 years) were examined using 320-row area detector computed tomography (320-ADCT). All participants swallowed a 10 mL honey-thick barium bolus upon command while seated in a 45° semi-reclining position. Multi-planar reconstruction images and dynamic 3D-CT images were obtained using Aquilion ONE software. Pharyngeal 2D area and 3D volume measurements were taken before swallowing and at the frame depicting maximum pharyngeal constriction. Pharyngeal volume before swallowing (PVhold) was accurately predicted by 2D area (R2 = 0.816). Adding height and sex to the model increased R2 to 0.836. Regarding pharyngeal volume during maximum constriction (PVmax), 2D area also exhibited acceptable predictive power (R2 = 0.777). However, analysis of statistical residuals and outliers revealed a greater tendency for prediction errors when there is less complete constriction of the pharynx as well as asymmetry in bolus flow or movement. Findings highlight the importance of routinely incorporating anterior-posterior views during VFSS exams. Future work is needed to determine clinical utility of pharyngeal volume measurements derived from 320-ADCT.
期刊介绍:
Dysphagia aims to serve as a voice for the benefit of the patient. The journal is devoted exclusively to swallowing and its disorders. The purpose of the journal is to provide a source of information to the flourishing dysphagia community. Over the past years, the field of dysphagia has grown rapidly, and the community of dysphagia researchers have galvanized with ambition to represent dysphagia patients. In addition to covering a myriad of disciplines in medicine and speech pathology, the following topics are also covered, but are not limited to: bio-engineering, deglutition, esophageal motility, immunology, and neuro-gastroenterology. The journal aims to foster a growing need for further dysphagia investigation, to disseminate knowledge through research, and to stimulate communication among interested professionals. The journal publishes original papers, technical and instrumental notes, letters to the editor, and review articles.