风速测量方法对温暖晴天有限气流条件下 MRT 和 PET 值的影响。

IF 3 3区 地球科学 Q2 BIOPHYSICS
International Journal of Biometeorology Pub Date : 2024-04-01 Epub Date: 2024-01-22 DOI:10.1007/s00484-024-02623-7
Katarzyna Lindner-Cendrowska, Magdalena Kuchcik
{"title":"风速测量方法对温暖晴天有限气流条件下 MRT 和 PET 值的影响。","authors":"Katarzyna Lindner-Cendrowska, Magdalena Kuchcik","doi":"10.1007/s00484-024-02623-7","DOIUrl":null,"url":null,"abstract":"<p><p>Wind speed is an important variable in the assessment of thermal comfort. Different types of meteorological devices provide different accuracy of air velocity (va) measurements, which under limited air flow conditions, may result in a discrepancy in actual thermal stress level. Simultaneous measurements on warm summer days, performed with a cup anemometer and hot-wire probe, prove that too high starting threshold of the first of these sensors can lead to a discrepancy of actual wind speed, and as a consequence can distort MRT (estimated with globe thermometers) and PET values on average up to 10 °C and 1 °C, respectively.</p>","PeriodicalId":588,"journal":{"name":"International Journal of Biometeorology","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The impact of wind speed measurement method on MRT and PET values in limited air flow conditions on warm, sunny days.\",\"authors\":\"Katarzyna Lindner-Cendrowska, Magdalena Kuchcik\",\"doi\":\"10.1007/s00484-024-02623-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Wind speed is an important variable in the assessment of thermal comfort. Different types of meteorological devices provide different accuracy of air velocity (va) measurements, which under limited air flow conditions, may result in a discrepancy in actual thermal stress level. Simultaneous measurements on warm summer days, performed with a cup anemometer and hot-wire probe, prove that too high starting threshold of the first of these sensors can lead to a discrepancy of actual wind speed, and as a consequence can distort MRT (estimated with globe thermometers) and PET values on average up to 10 °C and 1 °C, respectively.</p>\",\"PeriodicalId\":588,\"journal\":{\"name\":\"International Journal of Biometeorology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Biometeorology\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1007/s00484-024-02623-7\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Biometeorology","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1007/s00484-024-02623-7","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

风速是热舒适度评估中的一个重要变量。不同类型的气象设备提供的风速测量精度不同,在有限的气流条件下,可能导致实际热应力水平的差异。在温暖的夏日,使用杯式风速计和热线探头进行的同步测量证明,其中第一种传感器的起始阈值过高会导致实际风速出现偏差,因此会扭曲 MRT(使用球形温度计估算)和 PET 值,平均分别高达 10 °C 和 1 °C。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The impact of wind speed measurement method on MRT and PET values in limited air flow conditions on warm, sunny days.

The impact of wind speed measurement method on MRT and PET values in limited air flow conditions on warm, sunny days.

Wind speed is an important variable in the assessment of thermal comfort. Different types of meteorological devices provide different accuracy of air velocity (va) measurements, which under limited air flow conditions, may result in a discrepancy in actual thermal stress level. Simultaneous measurements on warm summer days, performed with a cup anemometer and hot-wire probe, prove that too high starting threshold of the first of these sensors can lead to a discrepancy of actual wind speed, and as a consequence can distort MRT (estimated with globe thermometers) and PET values on average up to 10 °C and 1 °C, respectively.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.40
自引率
9.40%
发文量
183
审稿时长
1 months
期刊介绍: The Journal publishes original research papers, review articles and short communications on studies examining the interactions between living organisms and factors of the natural and artificial atmospheric environment. Living organisms extend from single cell organisms, to plants and animals, including humans. The atmospheric environment includes climate and weather, electromagnetic radiation, and chemical and biological pollutants. The journal embraces basic and applied research and practical aspects such as living conditions, agriculture, forestry, and health. The journal is published for the International Society of Biometeorology, and most membership categories include a subscription to the Journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信