基于 Mn2SnO4 纳米立方体的简化分子印迹 ECL 传感器,用于灵敏检测利巴韦林

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Analyst Pub Date : 2024-01-22 DOI:10.1039/D3AN02077K
Kaida Kuang, Ya Li, Yang Chen, Yu Ji and Nengqin Jia
{"title":"基于 Mn2SnO4 纳米立方体的简化分子印迹 ECL 传感器,用于灵敏检测利巴韦林","authors":"Kaida Kuang, Ya Li, Yang Chen, Yu Ji and Nengqin Jia","doi":"10.1039/D3AN02077K","DOIUrl":null,"url":null,"abstract":"<p >Conventional single-signal or emerging sandwich-type double-signal electrochemiluminescence (ECL) immunosensors/aptasensors have offered accurate detection of small molecules, yet suffer from complicated setup, long processing time, and non-reusability. Here, we demonstrate a simplified molecularly imprinted ECL sensor based on Mn<small><sub>2</sub></small>SnO<small><sub>4</sub></small> nanocubes. As an n-type semiconductor, Mn<small><sub>2</sub></small>SnO<small><sub>4</sub></small> has numerous active sites that can capture electrons to accelerate chemical reactions, resulting in enhanced ECL activity and stability. For the first time, we verify a robust cathodic ECL emission of Mn<small><sub>2</sub></small>SnO<small><sub>4</sub></small> luminophores in the presence of K<small><sub>2</sub></small>S<small><sub>2</sub></small>O<small><sub>8</sub></small> coreactants. The proposed ECL sensor applies to the sensitive detection of ribavirin (RBV), endowing a wide linear range (1–2000 ng mL<small><sup>−1</sup></small>), low detection limit (0.85 ng mL<small><sup>−1</sup></small>, S/N = 3), high stability, specificity, and reproducibility, and the detection capability in real milk and chicken samples. This work highlights single semiconductor luminophore-driven molecularly imprinted ECL sensors, meeting the original aspiration of uncomplicated but high-performance sensing in food safety inspection.</p>","PeriodicalId":63,"journal":{"name":"Analyst","volume":null,"pages":null},"PeriodicalIF":3.6000,"publicationDate":"2024-01-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A simplified molecularly imprinted ECL sensor based on Mn2SnO4 nanocubes for sensitive detection of ribavirin†\",\"authors\":\"Kaida Kuang, Ya Li, Yang Chen, Yu Ji and Nengqin Jia\",\"doi\":\"10.1039/D3AN02077K\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Conventional single-signal or emerging sandwich-type double-signal electrochemiluminescence (ECL) immunosensors/aptasensors have offered accurate detection of small molecules, yet suffer from complicated setup, long processing time, and non-reusability. Here, we demonstrate a simplified molecularly imprinted ECL sensor based on Mn<small><sub>2</sub></small>SnO<small><sub>4</sub></small> nanocubes. As an n-type semiconductor, Mn<small><sub>2</sub></small>SnO<small><sub>4</sub></small> has numerous active sites that can capture electrons to accelerate chemical reactions, resulting in enhanced ECL activity and stability. For the first time, we verify a robust cathodic ECL emission of Mn<small><sub>2</sub></small>SnO<small><sub>4</sub></small> luminophores in the presence of K<small><sub>2</sub></small>S<small><sub>2</sub></small>O<small><sub>8</sub></small> coreactants. The proposed ECL sensor applies to the sensitive detection of ribavirin (RBV), endowing a wide linear range (1–2000 ng mL<small><sup>−1</sup></small>), low detection limit (0.85 ng mL<small><sup>−1</sup></small>, S/N = 3), high stability, specificity, and reproducibility, and the detection capability in real milk and chicken samples. This work highlights single semiconductor luminophore-driven molecularly imprinted ECL sensors, meeting the original aspiration of uncomplicated but high-performance sensing in food safety inspection.</p>\",\"PeriodicalId\":63,\"journal\":{\"name\":\"Analyst\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2024-01-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analyst\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/an/d3an02077k\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/an/d3an02077k","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

传统的单信号或新兴的夹层型双信号电化学发光(ECL)免疫传感器/自适应传感器可精确检测小分子,但存在设置复杂、处理时间长和不可重复使用等问题。在这里,我们展示了一种基于 Mn2SnO4 纳米立方体的简化分子印迹 ECL 传感器。作为一种 n 型半导体,Mn2SnO4 具有许多活性位点,可以捕获电子加速化学反应,从而增强 ECL 活性和稳定性。我们首次验证了 Mn2SnO4 发光体在 K2S2O8 核心反应物存在下的强阴极 ECL 发射。所提出的 ECL 传感器适用于利巴韦林(RBV)的灵敏检测,具有宽线性范围(1-2000 ng mL-1)、低检测限(0.85 ng mL-1,S/N = 3)、高稳定性、特异性和重现性,以及在真实牛奶和鸡肉样品中的检测能力。这项工作突出了单半导体发光体驱动的分子印迹 ECL 传感器,满足了食品安全检测中简单而高性能传感的最初愿望。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

A simplified molecularly imprinted ECL sensor based on Mn2SnO4 nanocubes for sensitive detection of ribavirin†

A simplified molecularly imprinted ECL sensor based on Mn2SnO4 nanocubes for sensitive detection of ribavirin†

A simplified molecularly imprinted ECL sensor based on Mn2SnO4 nanocubes for sensitive detection of ribavirin†

Conventional single-signal or emerging sandwich-type double-signal electrochemiluminescence (ECL) immunosensors/aptasensors have offered accurate detection of small molecules, yet suffer from complicated setup, long processing time, and non-reusability. Here, we demonstrate a simplified molecularly imprinted ECL sensor based on Mn2SnO4 nanocubes. As an n-type semiconductor, Mn2SnO4 has numerous active sites that can capture electrons to accelerate chemical reactions, resulting in enhanced ECL activity and stability. For the first time, we verify a robust cathodic ECL emission of Mn2SnO4 luminophores in the presence of K2S2O8 coreactants. The proposed ECL sensor applies to the sensitive detection of ribavirin (RBV), endowing a wide linear range (1–2000 ng mL−1), low detection limit (0.85 ng mL−1, S/N = 3), high stability, specificity, and reproducibility, and the detection capability in real milk and chicken samples. This work highlights single semiconductor luminophore-driven molecularly imprinted ECL sensors, meeting the original aspiration of uncomplicated but high-performance sensing in food safety inspection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: The home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信