治疗水平剂量计校准系数的长期稳定性及影响其稳定性的各种因素研究

IF 1 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION
MAPAN Pub Date : 2024-01-18 DOI:10.1007/s12647-023-00722-1
K. A. Greeshma, Sougata Rakshit, V. Sathian
{"title":"治疗水平剂量计校准系数的长期稳定性及影响其稳定性的各种因素研究","authors":"K. A. Greeshma,&nbsp;Sougata Rakshit,&nbsp;V. Sathian","doi":"10.1007/s12647-023-00722-1","DOIUrl":null,"url":null,"abstract":"<div><p>The Secondary Standard Dosimetry Laboratories (SSDLs) established through Primary Standard Dosimetry Laboratories are the authorized institutions for calibrating dosimeters used in teletherapy<sup>1</sup> all over the country. These calibrated dosimeters play a pivotal role for treatment planning in accelerator and teletherapy facilities for deciding the amount of dose and exposure to be delivered to the cancer patients during treatment. In India, Radiation Standards Section of Bhabha Atomic Research Centre is the authorized SSDL for providing calibration to teletherapy facilities for around 580 hospitals all over the country. The dosimeters are calibrated as per the standard protocol TRS 398, which is followed by standards laboratories all over the world. The accuracy of setting along with proper functioning of the dosimeters will together contribute for determination of calibration coefficient of the ionization chamber with accuracy. Controlling ambient atmospheric conditions like temperature, pressure and humidity factors within the recommended standard range also plays a major role in deriving calibration coefficient with utmost less uncertainty. A study was carried out on the variation of calibration coefficient of various chambers over a period of 15 years. It was found that variation of calibration coefficient of same chamber over this period varied within the limit measurement uncertainty of ± 1.5% only. Hence based on this study, the period for recalibration of dosimeters can be reviewed for a longer time unless it is subjected to damage or improper handling.</p></div>","PeriodicalId":689,"journal":{"name":"MAPAN","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-01-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study of Long-Term Stability of Calibration Coefficient of Therapy-Level Dosimeter and Various Factors Affecting its Stability\",\"authors\":\"K. A. Greeshma,&nbsp;Sougata Rakshit,&nbsp;V. Sathian\",\"doi\":\"10.1007/s12647-023-00722-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The Secondary Standard Dosimetry Laboratories (SSDLs) established through Primary Standard Dosimetry Laboratories are the authorized institutions for calibrating dosimeters used in teletherapy<sup>1</sup> all over the country. These calibrated dosimeters play a pivotal role for treatment planning in accelerator and teletherapy facilities for deciding the amount of dose and exposure to be delivered to the cancer patients during treatment. In India, Radiation Standards Section of Bhabha Atomic Research Centre is the authorized SSDL for providing calibration to teletherapy facilities for around 580 hospitals all over the country. The dosimeters are calibrated as per the standard protocol TRS 398, which is followed by standards laboratories all over the world. The accuracy of setting along with proper functioning of the dosimeters will together contribute for determination of calibration coefficient of the ionization chamber with accuracy. Controlling ambient atmospheric conditions like temperature, pressure and humidity factors within the recommended standard range also plays a major role in deriving calibration coefficient with utmost less uncertainty. A study was carried out on the variation of calibration coefficient of various chambers over a period of 15 years. It was found that variation of calibration coefficient of same chamber over this period varied within the limit measurement uncertainty of ± 1.5% only. Hence based on this study, the period for recalibration of dosimeters can be reviewed for a longer time unless it is subjected to damage or improper handling.</p></div>\",\"PeriodicalId\":689,\"journal\":{\"name\":\"MAPAN\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-01-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MAPAN\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s12647-023-00722-1\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MAPAN","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s12647-023-00722-1","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

通过一级标准剂量测定实验室建立的二级标准剂量测定实验室是校准全国各地远程治疗1 所用剂量计的授权机构。这些经过校准的剂量计在加速器和远程治疗设施的治疗规划中发挥着关键作用,可用于决定治疗期间向癌症患者提供的剂量和照射量。在印度,巴哈原子研究中心辐射标准部是经授权的 SSDL,为全国约 580 家医院的远程治疗设施提供校准服务。剂量计按照 TRS 398 标准协议进行校准,全世界的标准实验室都遵循该协议。设置的准确性和剂量计的正常运行将有助于准确确定电离室的校准系数。将环境大气条件,如温度、压力和湿度因素控制在建议的标准范围内,也对得出不确定性极小的校准系数起着重要作用。我们对 15 年间各种电离室校准系数的变化情况进行了研究。结果发现,在此期间,同一样品室校准系数的变化仅在± 1.5%的测量不确定度范围内。因此,根据这项研究,除非剂量计受到损坏或处理不当,否则重新校准剂量计的期限可以延长。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Study of Long-Term Stability of Calibration Coefficient of Therapy-Level Dosimeter and Various Factors Affecting its Stability

Study of Long-Term Stability of Calibration Coefficient of Therapy-Level Dosimeter and Various Factors Affecting its Stability

The Secondary Standard Dosimetry Laboratories (SSDLs) established through Primary Standard Dosimetry Laboratories are the authorized institutions for calibrating dosimeters used in teletherapy1 all over the country. These calibrated dosimeters play a pivotal role for treatment planning in accelerator and teletherapy facilities for deciding the amount of dose and exposure to be delivered to the cancer patients during treatment. In India, Radiation Standards Section of Bhabha Atomic Research Centre is the authorized SSDL for providing calibration to teletherapy facilities for around 580 hospitals all over the country. The dosimeters are calibrated as per the standard protocol TRS 398, which is followed by standards laboratories all over the world. The accuracy of setting along with proper functioning of the dosimeters will together contribute for determination of calibration coefficient of the ionization chamber with accuracy. Controlling ambient atmospheric conditions like temperature, pressure and humidity factors within the recommended standard range also plays a major role in deriving calibration coefficient with utmost less uncertainty. A study was carried out on the variation of calibration coefficient of various chambers over a period of 15 years. It was found that variation of calibration coefficient of same chamber over this period varied within the limit measurement uncertainty of ± 1.5% only. Hence based on this study, the period for recalibration of dosimeters can be reviewed for a longer time unless it is subjected to damage or improper handling.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
MAPAN
MAPAN 工程技术-物理:应用
CiteScore
2.30
自引率
20.00%
发文量
91
审稿时长
3 months
期刊介绍: MAPAN-Journal Metrology Society of India is a quarterly publication. It is exclusively devoted to Metrology (Scientific, Industrial or Legal). It has been fulfilling an important need of Metrologists and particularly of quality practitioners by publishing exclusive articles on scientific, industrial and legal metrology. The journal publishes research communication or technical articles of current interest in measurement science; original work, tutorial or survey papers in any metrology related area; reviews and analytical studies in metrology; case studies on reliability, uncertainty in measurements; and reports and results of intercomparison and proficiency testing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信