印度一家三级医疗中心经支气管低温结节活检、经支气管结节内镊子活检和经支气管针吸术治疗纵隔病变的比较结果(COLD-FORCEPS 研究)。

IF 1.1 Q4 RESPIRATORY SYSTEM
Manu Madan, A J Mahendran, Rohit Kumar, Yash Kedia, Rajnish Kaushik, Pranav Ish, Shibdas Chakrabarti, Neeraj Kumar Gupta, Nitesh Gupta
{"title":"印度一家三级医疗中心经支气管低温结节活检、经支气管结节内镊子活检和经支气管针吸术治疗纵隔病变的比较结果(COLD-FORCEPS 研究)。","authors":"Manu Madan, A J Mahendran, Rohit Kumar, Yash Kedia, Rajnish Kaushik, Pranav Ish, Shibdas Chakrabarti, Neeraj Kumar Gupta, Nitesh Gupta","doi":"10.4081/monaldi.2024.2813","DOIUrl":null,"url":null,"abstract":"<p><p>Endobronchial ultrasound (EBUS) guided mediastinal cryobiopsy, and intranodal forceps biopsy are newer modalities for sampling mediastinal lymph nodes. The data regarding the diagnostic yield of both modalities is scarce. Patients were recruited retrospectively from our existing database. Patients who had undergone both an EBUS guided mediastinal cryobiopsy and an intranodal forceps biopsy were enrolled in the study. The final diagnosis was made with a clinical-pathological-radiological assessment and clinico-radiological follow-up after one month. A total of 34 patients were enrolled in the study who had undergone both EBUS guided mediastinal cryobiopsy and intranodal forceps biopsy and had complete data available, including 1-month follow-up data. The sample adequacy rate of EBUS-transbronchial needle aspiration (EBUS-TBNA), EBUS-TBNA with mediastinal cryobiopsy, and EBUS-TBNA with intranodal forceps biopsy was 94.11%, 97.05%, and 94.11%, respectively (p=0.56). The diagnostic yield achieved in EBUS-TBNA, EBUS-TBNA with mediastinal cryobiopsy, and EBUS-TBNA with intranodal forceps biopsy was 73.52%, 82.35%, and 79.41%, respectively (p=0.38). No major complications were seen in any patient. To conclude, adding EBUS guided mediastinal cryobiopsy and intranodal forceps biopsy to EBUS-TBNA may not be superior to routine EBUS-TBNA.</p>","PeriodicalId":51593,"journal":{"name":"Monaldi Archives for Chest Disease","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative yield of transbronchial cryo-nodal biopsy, transbronchial intra-nodal forceps biopsy, and transbronchial needle aspiration for mediastinal lesions at a tertiary care center in India (COLD-FORCEPS study).\",\"authors\":\"Manu Madan, A J Mahendran, Rohit Kumar, Yash Kedia, Rajnish Kaushik, Pranav Ish, Shibdas Chakrabarti, Neeraj Kumar Gupta, Nitesh Gupta\",\"doi\":\"10.4081/monaldi.2024.2813\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Endobronchial ultrasound (EBUS) guided mediastinal cryobiopsy, and intranodal forceps biopsy are newer modalities for sampling mediastinal lymph nodes. The data regarding the diagnostic yield of both modalities is scarce. Patients were recruited retrospectively from our existing database. Patients who had undergone both an EBUS guided mediastinal cryobiopsy and an intranodal forceps biopsy were enrolled in the study. The final diagnosis was made with a clinical-pathological-radiological assessment and clinico-radiological follow-up after one month. A total of 34 patients were enrolled in the study who had undergone both EBUS guided mediastinal cryobiopsy and intranodal forceps biopsy and had complete data available, including 1-month follow-up data. The sample adequacy rate of EBUS-transbronchial needle aspiration (EBUS-TBNA), EBUS-TBNA with mediastinal cryobiopsy, and EBUS-TBNA with intranodal forceps biopsy was 94.11%, 97.05%, and 94.11%, respectively (p=0.56). The diagnostic yield achieved in EBUS-TBNA, EBUS-TBNA with mediastinal cryobiopsy, and EBUS-TBNA with intranodal forceps biopsy was 73.52%, 82.35%, and 79.41%, respectively (p=0.38). No major complications were seen in any patient. To conclude, adding EBUS guided mediastinal cryobiopsy and intranodal forceps biopsy to EBUS-TBNA may not be superior to routine EBUS-TBNA.</p>\",\"PeriodicalId\":51593,\"journal\":{\"name\":\"Monaldi Archives for Chest Disease\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Monaldi Archives for Chest Disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4081/monaldi.2024.2813\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Monaldi Archives for Chest Disease","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/monaldi.2024.2813","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

摘要

支气管内超声(EBUS)引导下的纵隔冷冻活检和结节内镊子活检是纵隔淋巴结取样的新方法。有关这两种方法诊断率的数据很少。我们从现有的数据库中回顾性地招募了患者。同时接受过 EBUS 引导下纵隔冷冻活检和结节内镊子活检的患者被纳入研究。通过临床病理放射学评估和一个月后的临床放射学随访做出最终诊断。共有 34 名患者接受了 EBUS 引导下的纵隔冷冻活检和结节内钳活检,并提供了完整的数据,包括 1 个月的随访数据。EBUS-经支气管针吸术(EBUS-TBNA)、EBUS-TBNA配合纵隔冷冻活检术和EBUS-TBNA配合结节内钳活检术的样本充分率分别为94.11%、97.05%和94.11%(P=0.56)。EBUS-TBNA、EBUS-TBNA伴纵隔冷冻活检和EBUS-TBNA伴结节内钳活检的诊断率分别为73.52%、82.35%和79.41%(P=0.38)。所有患者均未出现重大并发症。总之,在EBUS-TBNA的基础上增加EBUS引导纵隔冷冻活检和结节内镊子活检可能不会优于常规EBUS-TBNA。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative yield of transbronchial cryo-nodal biopsy, transbronchial intra-nodal forceps biopsy, and transbronchial needle aspiration for mediastinal lesions at a tertiary care center in India (COLD-FORCEPS study).

Endobronchial ultrasound (EBUS) guided mediastinal cryobiopsy, and intranodal forceps biopsy are newer modalities for sampling mediastinal lymph nodes. The data regarding the diagnostic yield of both modalities is scarce. Patients were recruited retrospectively from our existing database. Patients who had undergone both an EBUS guided mediastinal cryobiopsy and an intranodal forceps biopsy were enrolled in the study. The final diagnosis was made with a clinical-pathological-radiological assessment and clinico-radiological follow-up after one month. A total of 34 patients were enrolled in the study who had undergone both EBUS guided mediastinal cryobiopsy and intranodal forceps biopsy and had complete data available, including 1-month follow-up data. The sample adequacy rate of EBUS-transbronchial needle aspiration (EBUS-TBNA), EBUS-TBNA with mediastinal cryobiopsy, and EBUS-TBNA with intranodal forceps biopsy was 94.11%, 97.05%, and 94.11%, respectively (p=0.56). The diagnostic yield achieved in EBUS-TBNA, EBUS-TBNA with mediastinal cryobiopsy, and EBUS-TBNA with intranodal forceps biopsy was 73.52%, 82.35%, and 79.41%, respectively (p=0.38). No major complications were seen in any patient. To conclude, adding EBUS guided mediastinal cryobiopsy and intranodal forceps biopsy to EBUS-TBNA may not be superior to routine EBUS-TBNA.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
1
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信