新开发的平行板室在电子束中的特性表现

IF 0.7 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Journal of Medical Physics Pub Date : 2023-10-01 Epub Date: 2023-12-05 DOI:10.4103/jmp.jmp_76_23
Sathiyan Saminathan, Mageshraja Kannan, K M Ganesh, James Mazarello, Rahul Fernandes
{"title":"新开发的平行板室在电子束中的特性表现","authors":"Sathiyan Saminathan, Mageshraja Kannan, K M Ganesh, James Mazarello, Rahul Fernandes","doi":"10.4103/jmp.jmp_76_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To investigate the dosimetric performance of newly developed parallel plate chamber in electron beams.</p><p><strong>Materials and methods: </strong>Rosalina Instruments India Private Limited (Mumbai, Maharashtra, India) has designed and fabricated PRATT2 parallel plate chamber. The various dosimetric characteristics, including pre- and post-irradiation leakage, stability, polarity effect, chamber response with bias voltage, dose linearity, dose rate effect, and chamber absorbed dose calibration, were performed for the developed chamber. The electron beam energies of 4, 6, 8, and 15MeV were used in this study.</p><p><strong>Results: </strong>The pre- and post-irradiation leakage of the developed chamber was within the acceptable limit. The chamber shows good stability over the electron beams used in this study. The maximum error in polarity effect was 0.7% for the developed chamber. The chamber shows the good linear response with dose, and its response is independent of the dose rate for all electron beams. The beam quality correction factor (k<sub>Q, Q0</sub>) was determined for the all electron beam energies, which was used for determination absorbed dose in electron beams.</p><p><strong>Discussion: </strong>The developed parallel plate chamber (PRATT2) is suitable for dosimetry of electron beams in radiotherapy. The chamber is cost effective and shows precise and reproducible response. The study carried out confirms that the newly designed and fabricated ion chamber can be used in the measurement of absorbed dose for therapeutic electron beams.</p>","PeriodicalId":51719,"journal":{"name":"Journal of Medical Physics","volume":"48 4","pages":"333-337"},"PeriodicalIF":0.7000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10783180/pdf/","citationCount":"0","resultStr":"{\"title\":\"Characteristics Performance of Newly Developed Parallel Plate Chamber in Electron Beams.\",\"authors\":\"Sathiyan Saminathan, Mageshraja Kannan, K M Ganesh, James Mazarello, Rahul Fernandes\",\"doi\":\"10.4103/jmp.jmp_76_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>To investigate the dosimetric performance of newly developed parallel plate chamber in electron beams.</p><p><strong>Materials and methods: </strong>Rosalina Instruments India Private Limited (Mumbai, Maharashtra, India) has designed and fabricated PRATT2 parallel plate chamber. The various dosimetric characteristics, including pre- and post-irradiation leakage, stability, polarity effect, chamber response with bias voltage, dose linearity, dose rate effect, and chamber absorbed dose calibration, were performed for the developed chamber. The electron beam energies of 4, 6, 8, and 15MeV were used in this study.</p><p><strong>Results: </strong>The pre- and post-irradiation leakage of the developed chamber was within the acceptable limit. The chamber shows good stability over the electron beams used in this study. The maximum error in polarity effect was 0.7% for the developed chamber. The chamber shows the good linear response with dose, and its response is independent of the dose rate for all electron beams. The beam quality correction factor (k<sub>Q, Q0</sub>) was determined for the all electron beam energies, which was used for determination absorbed dose in electron beams.</p><p><strong>Discussion: </strong>The developed parallel plate chamber (PRATT2) is suitable for dosimetry of electron beams in radiotherapy. The chamber is cost effective and shows precise and reproducible response. The study carried out confirms that the newly designed and fabricated ion chamber can be used in the measurement of absorbed dose for therapeutic electron beams.</p>\",\"PeriodicalId\":51719,\"journal\":{\"name\":\"Journal of Medical Physics\",\"volume\":\"48 4\",\"pages\":\"333-337\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10783180/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jmp.jmp_76_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jmp.jmp_76_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/5 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:研究新开发的平行板室在电子束中的剂量测定性能:研究新开发的平行板室在电子束中的剂量测定性能:Rosalina Instruments India Private Limited(印度马哈拉施特拉邦孟买)设计并制造了 PRATT2 平行板室。对所开发的腔室进行了各种剂量测定,包括辐照前后的泄漏、稳定性、极性效应、腔室对偏置电压的响应、剂量线性、剂量率效应和腔室吸收剂量校准。研究使用的电子束能量分别为 4、6、8 和 15MeV:结果:所开发的腔室在辐照前后的泄漏量都在可接受的范围内。在本研究使用的电子束中,腔室表现出良好的稳定性。所开发的腔室在极性效应方面的最大误差为 0.7%。对于所有的电子束,腔室都显示出良好的剂量线性响应,并且其响应与剂量率无关。所有电子束能量的束流质量校正因子(kQ, Q0)均已确定,可用于确定电子束的吸收剂量:讨论:所开发的平行板室(PRATT2)适用于放射治疗中的电子束剂量测定。该箱成本低廉,反应精确且可重复。研究证实,新设计和制造的离子室可用于测量治疗电子束的吸收剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characteristics Performance of Newly Developed Parallel Plate Chamber in Electron Beams.

Background: To investigate the dosimetric performance of newly developed parallel plate chamber in electron beams.

Materials and methods: Rosalina Instruments India Private Limited (Mumbai, Maharashtra, India) has designed and fabricated PRATT2 parallel plate chamber. The various dosimetric characteristics, including pre- and post-irradiation leakage, stability, polarity effect, chamber response with bias voltage, dose linearity, dose rate effect, and chamber absorbed dose calibration, were performed for the developed chamber. The electron beam energies of 4, 6, 8, and 15MeV were used in this study.

Results: The pre- and post-irradiation leakage of the developed chamber was within the acceptable limit. The chamber shows good stability over the electron beams used in this study. The maximum error in polarity effect was 0.7% for the developed chamber. The chamber shows the good linear response with dose, and its response is independent of the dose rate for all electron beams. The beam quality correction factor (kQ, Q0) was determined for the all electron beam energies, which was used for determination absorbed dose in electron beams.

Discussion: The developed parallel plate chamber (PRATT2) is suitable for dosimetry of electron beams in radiotherapy. The chamber is cost effective and shows precise and reproducible response. The study carried out confirms that the newly designed and fabricated ion chamber can be used in the measurement of absorbed dose for therapeutic electron beams.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical Physics
Journal of Medical Physics RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.10
自引率
11.10%
发文量
55
审稿时长
30 weeks
期刊介绍: JOURNAL OF MEDICAL PHYSICS is the official journal of Association of Medical Physicists of India (AMPI). The association has been bringing out a quarterly publication since 1976. Till the end of 1993, it was known as Medical Physics Bulletin, which then became Journal of Medical Physics. The main objective of the Journal is to serve as a vehicle of communication to highlight all aspects of the practice of medical radiation physics. The areas covered include all aspects of the application of radiation physics to biological sciences, radiotherapy, radiodiagnosis, nuclear medicine, dosimetry and radiation protection. Papers / manuscripts dealing with the aspects of physics related to cancer therapy / radiobiology also fall within the scope of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信