Lincoln DE Campos Fruchi, Murilo Priori Alcalde, Pablo Amoroso-Silva, Rodrigo Ricci Vivan, Clovis Monteiro Bramante, Marco Antônio Húngaro Duarte
{"title":"用显微 CT 评估不同解剖类型的弯管根尖三分之一处的充填物去除效果。","authors":"Lincoln DE Campos Fruchi, Murilo Priori Alcalde, Pablo Amoroso-Silva, Rodrigo Ricci Vivan, Clovis Monteiro Bramante, Marco Antônio Húngaro Duarte","doi":"10.22037/iej.v19i1.27511","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The aim of this study was to assess the effectiveness of filling removal material from the apical third of curved mesial root canals of mandibular molars. Reciprocating instrumentation followed by additional rotary instrumentation with instruments made of alloys with different heat treatments was evaluated.</p><p><strong>Materials and methods: </strong>Thirty-six mesial roots of mandibular molars were divided into two groups: Group Class IV consisted of 16 roots with two independent canals, and Group Class II consisted of 20 roots with two canals that merged into one at their apical level. Each of these two groups were further divided into two subgroups, according to the additional rotary instrument used after the reciprocating instrumentation: Group RH and Group RM for Hyflex and Mtwo, respectively. After each procedural step, the roots were scanned by micro-tomography. After each step of filling removal, the Wilcoxon matched pair test and the Mann-Whitney test were used for the evaluation between groups. The significance level adopted was 5%.</p><p><strong>Results: </strong>Significant differences were observed between groups with different Class II and Class IV anatomies, regarding filling removal after Reciproc (<i>P</i><0.05). After the use of an additional rotary instrumentation, no differences were observed between the two groups (<i>P</i>>0.05).</p><p><strong>Conclusions: </strong>In the apical third of mesial roots of mandibular molars with Class II anatomy, an additional rotary instrumentation was shown to be necessary for improving the removal of filling material after using the single-file reciprocating instrumentation technique.</p>","PeriodicalId":14534,"journal":{"name":"Iranian Endodontic Journal","volume":"19 1","pages":"22-27"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10787183/pdf/","citationCount":"0","resultStr":"{\"title\":\"Micro-CT Assessment of Filling Removal Effectiveness in the Apical Third of Curved Canals with Different Types of Anatomy.\",\"authors\":\"Lincoln DE Campos Fruchi, Murilo Priori Alcalde, Pablo Amoroso-Silva, Rodrigo Ricci Vivan, Clovis Monteiro Bramante, Marco Antônio Húngaro Duarte\",\"doi\":\"10.22037/iej.v19i1.27511\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The aim of this study was to assess the effectiveness of filling removal material from the apical third of curved mesial root canals of mandibular molars. Reciprocating instrumentation followed by additional rotary instrumentation with instruments made of alloys with different heat treatments was evaluated.</p><p><strong>Materials and methods: </strong>Thirty-six mesial roots of mandibular molars were divided into two groups: Group Class IV consisted of 16 roots with two independent canals, and Group Class II consisted of 20 roots with two canals that merged into one at their apical level. Each of these two groups were further divided into two subgroups, according to the additional rotary instrument used after the reciprocating instrumentation: Group RH and Group RM for Hyflex and Mtwo, respectively. After each procedural step, the roots were scanned by micro-tomography. After each step of filling removal, the Wilcoxon matched pair test and the Mann-Whitney test were used for the evaluation between groups. The significance level adopted was 5%.</p><p><strong>Results: </strong>Significant differences were observed between groups with different Class II and Class IV anatomies, regarding filling removal after Reciproc (<i>P</i><0.05). After the use of an additional rotary instrumentation, no differences were observed between the two groups (<i>P</i>>0.05).</p><p><strong>Conclusions: </strong>In the apical third of mesial roots of mandibular molars with Class II anatomy, an additional rotary instrumentation was shown to be necessary for improving the removal of filling material after using the single-file reciprocating instrumentation technique.</p>\",\"PeriodicalId\":14534,\"journal\":{\"name\":\"Iranian Endodontic Journal\",\"volume\":\"19 1\",\"pages\":\"22-27\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10787183/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Endodontic Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22037/iej.v19i1.27511\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Endodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22037/iej.v19i1.27511","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
摘要
简介本研究旨在评估从下颌磨牙弯曲中侧根管根尖三分之一处去除充填材料的效果。在使用往复式器械后,再使用经不同热处理的合金制成的器械进行额外的旋转器械:下颌磨牙的 36 个中根分为两组:IV 类包括 16 个具有两个独立根管的牙根,II 类包括 20 个具有两个根管的牙根,这两个根管在根尖处合二为一。根据往复式器械治疗后使用的附加旋转器械的不同,这两组又分为两个亚组:RH组和RM组分别代表Hyflex和Mtwo。在每个程序步骤之后,都要对牙根进行显微断层扫描。在每个填充物去除步骤后,采用 Wilcoxon 配对检验和 Mann-Whitney 检验进行组间评价。采用的显著性水平为 5%:结果:在 Reciproc 后的充填物去除方面,不同 II 类和 IV 类解剖结构的组间存在显著差异(PP>0.05):结论:在下颌磨牙的中根根尖三分之一处,如果解剖结构为 II 类,那么在使用单排往复式器械技术后,有必要使用额外的旋转器械来提高充填材料的去除率。
Micro-CT Assessment of Filling Removal Effectiveness in the Apical Third of Curved Canals with Different Types of Anatomy.
Introduction: The aim of this study was to assess the effectiveness of filling removal material from the apical third of curved mesial root canals of mandibular molars. Reciprocating instrumentation followed by additional rotary instrumentation with instruments made of alloys with different heat treatments was evaluated.
Materials and methods: Thirty-six mesial roots of mandibular molars were divided into two groups: Group Class IV consisted of 16 roots with two independent canals, and Group Class II consisted of 20 roots with two canals that merged into one at their apical level. Each of these two groups were further divided into two subgroups, according to the additional rotary instrument used after the reciprocating instrumentation: Group RH and Group RM for Hyflex and Mtwo, respectively. After each procedural step, the roots were scanned by micro-tomography. After each step of filling removal, the Wilcoxon matched pair test and the Mann-Whitney test were used for the evaluation between groups. The significance level adopted was 5%.
Results: Significant differences were observed between groups with different Class II and Class IV anatomies, regarding filling removal after Reciproc (P<0.05). After the use of an additional rotary instrumentation, no differences were observed between the two groups (P>0.05).
Conclusions: In the apical third of mesial roots of mandibular molars with Class II anatomy, an additional rotary instrumentation was shown to be necessary for improving the removal of filling material after using the single-file reciprocating instrumentation technique.
期刊介绍:
The Iranian Endodontic Journal (IEJ) is an international peer-reviewed biomedical publication, the aim of which is to provide a scientific medium of communication for researchers throughout the globe. IEJ aims to publish the highest quality articles, both clinical and scientific, on all aspects of Endodontics. The journal is an official Journal of the Iranian Center for Endodontic Research (ICER) and the Iranian Association of Endodontists (IAE). The Journal welcomes articles related to the scientific or applied aspects of endodontics e.g. original researches, systematic reviews, meta-analyses, review articles, clinical trials, case series/reports, hypotheses, letters to the editor, etc. From the beginning (i.e. since 2006), the IEJ was the first open access endodontic journal in the world, which gave readers free and instant access to published articles and enabling them faster discovery of the latest endodontic research.