富氮共价有机框架作为有效测定多环芳烃的实用涂层

IF 6.1 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Yuefan Liu , Suxin Zhou , Yixin Kuang , Xiaoying Feng , Zhuo Wang , Zitao Shen , Ningbo Zhou , Juan Zheng , Gangfeng Ouyang
{"title":"富氮共价有机框架作为有效测定多环芳烃的实用涂层","authors":"Yuefan Liu ,&nbsp;Suxin Zhou ,&nbsp;Yixin Kuang ,&nbsp;Xiaoying Feng ,&nbsp;Zhuo Wang ,&nbsp;Zitao Shen ,&nbsp;Ningbo Zhou ,&nbsp;Juan Zheng ,&nbsp;Gangfeng Ouyang","doi":"10.1016/j.talanta.2024.125655","DOIUrl":null,"url":null,"abstract":"<div><p><span><span>Polycyclic aromatic hydrocarbons<span> (PAHs) are high-profile organic pollutants to be poisonous, carcinogenic, and mutagenic, and widely distributed at trace levels in the environment. In order to effectively enrich PAHs, two stable covalent organic frameworks (COFs, TAPT-OMe-PDA and TPB-DMTP) were prepared by combining 2,4,6-tri(4-aminophenyl)-1,3,5-triazine (TAPT) and 1,3,5-tri(4-aminophenyl) benzene (TAPB) with 2,5-dimethoxy-phenyl-1,4-diformaldehyde (OMe-PDA), respectively. Even though the surface area of TAPT-OMe-PDA was much lower than that of TPB-DMTP, it still demonstrated much better extraction efficiencies towards PAHs as the </span></span>solid phase microextraction (SPME) coating. Therefore, the TAPT-OMe-PDA coated fiber was coupled with gas chromatography-mass spectrometry (GC-MS) to establish a practical and sensitive method, after the extraction parameters (extraction time, extraction temperature, desorption temperature, desorption time, salt concentration and pH) were optimized. This developed analytical method showed wide linear ranges, low limits of detection, good repeatability and reproducibility. Finally, five PAHs in three water samples were detected and quantified precisely (2.72–38.7 ng·L</span><sup>-1</sup>) with satisfactory recoveries (88.3%–118%).</p></div>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"271 ","pages":"Article 125655"},"PeriodicalIF":6.1000,"publicationDate":"2024-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nitrogen-rich covalent organic framework as a practical coating for effective determinations of polycyclic aromatic hydrocarbons\",\"authors\":\"Yuefan Liu ,&nbsp;Suxin Zhou ,&nbsp;Yixin Kuang ,&nbsp;Xiaoying Feng ,&nbsp;Zhuo Wang ,&nbsp;Zitao Shen ,&nbsp;Ningbo Zhou ,&nbsp;Juan Zheng ,&nbsp;Gangfeng Ouyang\",\"doi\":\"10.1016/j.talanta.2024.125655\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p><span><span>Polycyclic aromatic hydrocarbons<span> (PAHs) are high-profile organic pollutants to be poisonous, carcinogenic, and mutagenic, and widely distributed at trace levels in the environment. In order to effectively enrich PAHs, two stable covalent organic frameworks (COFs, TAPT-OMe-PDA and TPB-DMTP) were prepared by combining 2,4,6-tri(4-aminophenyl)-1,3,5-triazine (TAPT) and 1,3,5-tri(4-aminophenyl) benzene (TAPB) with 2,5-dimethoxy-phenyl-1,4-diformaldehyde (OMe-PDA), respectively. Even though the surface area of TAPT-OMe-PDA was much lower than that of TPB-DMTP, it still demonstrated much better extraction efficiencies towards PAHs as the </span></span>solid phase microextraction (SPME) coating. Therefore, the TAPT-OMe-PDA coated fiber was coupled with gas chromatography-mass spectrometry (GC-MS) to establish a practical and sensitive method, after the extraction parameters (extraction time, extraction temperature, desorption temperature, desorption time, salt concentration and pH) were optimized. This developed analytical method showed wide linear ranges, low limits of detection, good repeatability and reproducibility. Finally, five PAHs in three water samples were detected and quantified precisely (2.72–38.7 ng·L</span><sup>-1</sup>) with satisfactory recoveries (88.3%–118%).</p></div>\",\"PeriodicalId\":435,\"journal\":{\"name\":\"Talanta\",\"volume\":\"271 \",\"pages\":\"Article 125655\"},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2024-01-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0039914024000341\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0039914024000341","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

多环芳烃(PAHs)是备受关注的有机污染物,具有毒性、致癌性和致突变性,广泛分布于环境中的痕量水平。为了有效富集多环芳烃,研究人员将 2,4,6-三(4-氨基苯基)-1,3,5-三嗪(TAPT)和 1,3,5-三(4-氨基苯基)苯(TAPB)分别与 2,5-二甲氧基苯基-1,4-二甲醛(OMe-PDA)结合,制备了两种稳定的共价有机框架(COFs),即 TAPT-OMe-PDA 和 TPB-DMTP。尽管 TAPT-OMe-PDA 的表面积远低于 TPB-DMTP,但作为固相微萃取(SPME)涂层,它对多环芳烃的萃取效率仍然要高得多。因此,在对萃取参数(萃取时间、萃取温度、解吸温度、解吸时间、盐浓度和 pH 值)进行优化后,将 TAPT-OMe-PDA 涂层纤维与气相色谱-质谱(GC-MS)联用,建立了一种实用、灵敏的分析方法。所建立的分析方法具有衬度范围宽、检出限低、重复性和重现性好的特点。结果表明,三种水样中的五种多环芳烃均得到了准确的检测和定量(2.72-38.7 ng L-1),回收率(88.3%-118%)令人满意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Nitrogen-rich covalent organic framework as a practical coating for effective determinations of polycyclic aromatic hydrocarbons

Nitrogen-rich covalent organic framework as a practical coating for effective determinations of polycyclic aromatic hydrocarbons

Nitrogen-rich covalent organic framework as a practical coating for effective determinations of polycyclic aromatic hydrocarbons

Polycyclic aromatic hydrocarbons (PAHs) are high-profile organic pollutants to be poisonous, carcinogenic, and mutagenic, and widely distributed at trace levels in the environment. In order to effectively enrich PAHs, two stable covalent organic frameworks (COFs, TAPT-OMe-PDA and TPB-DMTP) were prepared by combining 2,4,6-tri(4-aminophenyl)-1,3,5-triazine (TAPT) and 1,3,5-tri(4-aminophenyl) benzene (TAPB) with 2,5-dimethoxy-phenyl-1,4-diformaldehyde (OMe-PDA), respectively. Even though the surface area of TAPT-OMe-PDA was much lower than that of TPB-DMTP, it still demonstrated much better extraction efficiencies towards PAHs as the solid phase microextraction (SPME) coating. Therefore, the TAPT-OMe-PDA coated fiber was coupled with gas chromatography-mass spectrometry (GC-MS) to establish a practical and sensitive method, after the extraction parameters (extraction time, extraction temperature, desorption temperature, desorption time, salt concentration and pH) were optimized. This developed analytical method showed wide linear ranges, low limits of detection, good repeatability and reproducibility. Finally, five PAHs in three water samples were detected and quantified precisely (2.72–38.7 ng·L-1) with satisfactory recoveries (88.3%–118%).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta
Talanta 化学-分析化学
CiteScore
12.30
自引率
4.90%
发文量
861
审稿时长
29 days
期刊介绍: Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome. Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信