{"title":"-20°C和-150°C条件下保存的健康人尸检组织的组织形态学和DNA质量的变化","authors":"Dusan N. Radojevic ,&nbsp;Milos S. Todorovic ,&nbsp;Katarina M. Vitosevic ,&nbsp;Vanja Canovic ,&nbsp;Milena Pavicevic ,&nbsp;Zivana S. Slovic ,&nbsp;Ivana M. Andric ,&nbsp;Stevan Matic ,&nbsp;Danijela V. Todorovic","doi":"10.1016/j.legalmed.2024.102396","DOIUrl":null,"url":null,"abstract":"<div><p>The aim of this study was to compare the changes in tissue histomorphology and DNA quality in six different healthy tissues (brain, heart, lung, liver, spleen and kidney) exempted during autopsy of healthy individuals and storage at −20 °C and −150 °C three month. Tissue samples were obtained, divided by tissue and temperature group, and for each sample, tissue histomorphology and DNA (isolated from all tissues in duplicated − 72 samples of DNA) quality were analysed. Morphology of tissue samples was studied using H&amp;E staining. DNA was isolated using the phenol–chloroform-isoamyl alcohol method. To assess the concentration and purity of the DNA samples, we used a spectrophotometer to measure absorbance at wavelengths of 280 nm and 260 nm. The fragments of human telomerase reverse transcriptase (hTERT) gene were amplified from the DNA using PCR reaction and then visualised using the 2 % agarose gel. Samples stored at −150 °C sustained the highest degree of histomorphological damage, while samples stored at −20 °C were less degraded, compared to control. The liver samples stored at −20 °C had a mean DNA concentration (1030.4 ± 51.5 ng/μl) higher than the samples of liver tissue stored at −150 °C (497.4 ± 167.1 ng/μl) (p &lt; 0.001). Other tissues did not have statistically significantly different DNA concentration at both temperatures. Liver samples at −20 °C had degraded DNA, showed as the absence of hTERT gene in most of samples. Other tissue samples in both temperature groups had unfragmented DNA. Storing tissue samples at −20 °C is not inferior in terms of DNA yield and integrity, and possibly superior for tissue histomorphology, comparing with samples stored at −150⁰C.</p></div>","PeriodicalId":49913,"journal":{"name":"Legal Medicine","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The changes in tissue histomorphology and quality of DNA in healthy human autopsied tissues stored at −20 °C and −150 °C\",\"authors\":\"Dusan N. Radojevic ,&nbsp;Milos S. Todorovic ,&nbsp;Katarina M. Vitosevic ,&nbsp;Vanja Canovic ,&nbsp;Milena Pavicevic ,&nbsp;Zivana S. Slovic ,&nbsp;Ivana M. Andric ,&nbsp;Stevan Matic ,&nbsp;Danijela V. Todorovic\",\"doi\":\"10.1016/j.legalmed.2024.102396\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The aim of this study was to compare the changes in tissue histomorphology and DNA quality in six different healthy tissues (brain, heart, lung, liver, spleen and kidney) exempted during autopsy of healthy individuals and storage at −20 °C and −150 °C three month. Tissue samples were obtained, divided by tissue and temperature group, and for each sample, tissue histomorphology and DNA (isolated from all tissues in duplicated − 72 samples of DNA) quality were analysed. Morphology of tissue samples was studied using H&amp;E staining. DNA was isolated using the phenol–chloroform-isoamyl alcohol method. To assess the concentration and purity of the DNA samples, we used a spectrophotometer to measure absorbance at wavelengths of 280 nm and 260 nm. The fragments of human telomerase reverse transcriptase (hTERT) gene were amplified from the DNA using PCR reaction and then visualised using the 2 % agarose gel. Samples stored at −150 °C sustained the highest degree of histomorphological damage, while samples stored at −20 °C were less degraded, compared to control. The liver samples stored at −20 °C had a mean DNA concentration (1030.4 ± 51.5 ng/μl) higher than the samples of liver tissue stored at −150 °C (497.4 ± 167.1 ng/μl) (p &lt; 0.001). Other tissues did not have statistically significantly different DNA concentration at both temperatures. Liver samples at −20 °C had degraded DNA, showed as the absence of hTERT gene in most of samples. Other tissue samples in both temperature groups had unfragmented DNA. Storing tissue samples at −20 °C is not inferior in terms of DNA yield and integrity, and possibly superior for tissue histomorphology, comparing with samples stored at −150⁰C.</p></div>\",\"PeriodicalId\":49913,\"journal\":{\"name\":\"Legal Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-01-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Legal Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1344622324000063\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, LEGAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Legal Medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1344622324000063","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是比较健康人尸体解剖后在-20℃和-150℃条件下保存三个月的六种不同健康组织(脑、心、肺、肝、脾和肾)的组织形态学和 DNA 质量的变化。获得的组织样本按组织和温度组别进行划分,并对每个样本的组织形态学和 DNA(从所有组织中重复分离 - 72 个 DNA 样本)质量进行分析。使用 H&E 染色法研究组织样本的形态。DNA 采用苯酚-氯仿-异戊醇法分离。为了评估 DNA 样品的浓度和纯度,我们使用分光光度计在 280nm 和 260nm 波长处测量吸光度。利用 PCR 反应从 DNA 中扩增出人类端粒酶逆转录酶(hTERT)基因片段,然后用 2% 琼脂糖凝胶显像。与对照组相比,保存在-150°C的样本受到的组织形态学损伤程度最高,而保存在-20°C的样本受到的损伤程度较低。保存在-20°C的肝脏样本的平均DNA浓度(1030.4±51.5ng/μl)高于保存在-150°C的肝脏组织样本(497.4±167.1ng/μl)(p<0.001)。其他组织的 DNA 浓度在两种温度下没有明显的统计学差异。肝脏样本在-20°C时DNA降解,表现为大部分样本中没有hTERT基因。两组温度下的其他组织样本中都有未破碎的 DNA。与保存在-150⁰C的样本相比,保存在-20°C的组织样本在DNA产量和完整性方面并不逊色,在组织形态学方面可能更胜一筹。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The changes in tissue histomorphology and quality of DNA in healthy human autopsied tissues stored at −20 °C and −150 °C

The aim of this study was to compare the changes in tissue histomorphology and DNA quality in six different healthy tissues (brain, heart, lung, liver, spleen and kidney) exempted during autopsy of healthy individuals and storage at −20 °C and −150 °C three month. Tissue samples were obtained, divided by tissue and temperature group, and for each sample, tissue histomorphology and DNA (isolated from all tissues in duplicated − 72 samples of DNA) quality were analysed. Morphology of tissue samples was studied using H&E staining. DNA was isolated using the phenol–chloroform-isoamyl alcohol method. To assess the concentration and purity of the DNA samples, we used a spectrophotometer to measure absorbance at wavelengths of 280 nm and 260 nm. The fragments of human telomerase reverse transcriptase (hTERT) gene were amplified from the DNA using PCR reaction and then visualised using the 2 % agarose gel. Samples stored at −150 °C sustained the highest degree of histomorphological damage, while samples stored at −20 °C were less degraded, compared to control. The liver samples stored at −20 °C had a mean DNA concentration (1030.4 ± 51.5 ng/μl) higher than the samples of liver tissue stored at −150 °C (497.4 ± 167.1 ng/μl) (p < 0.001). Other tissues did not have statistically significantly different DNA concentration at both temperatures. Liver samples at −20 °C had degraded DNA, showed as the absence of hTERT gene in most of samples. Other tissue samples in both temperature groups had unfragmented DNA. Storing tissue samples at −20 °C is not inferior in terms of DNA yield and integrity, and possibly superior for tissue histomorphology, comparing with samples stored at −150⁰C.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Legal Medicine
Legal Medicine Nursing-Issues, Ethics and Legal Aspects
CiteScore
2.80
自引率
6.70%
发文量
119
审稿时长
7.9 weeks
期刊介绍: Legal Medicine provides an international forum for the publication of original articles, reviews and correspondence on subjects that cover practical and theoretical areas of interest relating to the wide range of legal medicine. Subjects covered include forensic pathology, toxicology, odontology, anthropology, criminalistics, immunochemistry, hemogenetics and forensic aspects of biological science with emphasis on DNA analysis and molecular biology. Submissions dealing with medicolegal problems such as malpractice, insurance, child abuse or ethics in medical practice are also acceptable.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信