新型高性能聚醚醚酮酮制成的最佳可摘局部义齿扣设计的体外研究

IF 3.2 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Pei-Wen Peng, May-Show Chen, Tzu-Yu Peng, Peng-Chien Huang, Hiroki Nikawa, Wei-Fang Lee
{"title":"新型高性能聚醚醚酮酮制成的最佳可摘局部义齿扣设计的体外研究","authors":"Pei-Wen Peng, May-Show Chen, Tzu-Yu Peng, Peng-Chien Huang, Hiroki Nikawa, Wei-Fang Lee","doi":"10.2186/jpr.jpr_d_23_00080","DOIUrl":null,"url":null,"abstract":"</p><p><b>Purpose:</b> This study aimed to investigate the retentive force and deformation of double Akers’ polyetherketoneketone (PEKK) clasps on removable partial dentures (RPDs) with varying designs and undercut depths.</p><p><b>Methods:</b> Thirty double Akers’ PEKK clasps with two different widths and heights (Groups I and II) were fabricated using computer-aided design and computer-aided manufacturing (CAD/CAM). Each design was further subdivided (<i>n</i> = 5) into three undercut depths (0.25, 0.50, and 0.75 mm). The retentive force of the clasps was measured after 10 years of clinical use (15,000 insertion/removal cycles), and the deformation of the clasp tips was analyzed before and after cycling.</p><p><b>Results:</b> Clasps with 0.50-mm and 0.75-mm undercut depths exhibited greater initial retentive forces (3.15–3.51 N) compared to those in the 0.25-mm undercut group (2.40–2.80 N). Group I maintained consistent retentive forces over the cycles (<i>P</i> = 0.345), whereas Group II showed declining forces after the initial use (<i>P</i> &lt; 0.003). In both groups, the 0.50-mm undercut exhibited a greater retentive force than the 0.25-mm (<i>P</i> &lt; 0.001 and <i>P</i> &lt; 0.004, respectively), with no significant differences between the 0.50-mm and 0.75-mm undercut depths. Despite a lower initial retentive force, the 0.25-mm undercut showed less deformation and clasp tip wear.</p><p><b>Conclusions:</b> The PEKK clasps did not exhibit significantly reduced retentive forces or permanent deformations after 15,000 fatigue cycles. These results suggest that the PEKK polymer displays superior mechanical properties as an esthetic clasp material, and clasps with 0.50-mm and 0.75-mm undercut depths are recommended for long-term clinical use.</p>\n<p></p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-01-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In vitro study of optimal removable partial denture clasp design made from novel high-performance polyetherketoneketone\",\"authors\":\"Pei-Wen Peng, May-Show Chen, Tzu-Yu Peng, Peng-Chien Huang, Hiroki Nikawa, Wei-Fang Lee\",\"doi\":\"10.2186/jpr.jpr_d_23_00080\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"</p><p><b>Purpose:</b> This study aimed to investigate the retentive force and deformation of double Akers’ polyetherketoneketone (PEKK) clasps on removable partial dentures (RPDs) with varying designs and undercut depths.</p><p><b>Methods:</b> Thirty double Akers’ PEKK clasps with two different widths and heights (Groups I and II) were fabricated using computer-aided design and computer-aided manufacturing (CAD/CAM). Each design was further subdivided (<i>n</i> = 5) into three undercut depths (0.25, 0.50, and 0.75 mm). The retentive force of the clasps was measured after 10 years of clinical use (15,000 insertion/removal cycles), and the deformation of the clasp tips was analyzed before and after cycling.</p><p><b>Results:</b> Clasps with 0.50-mm and 0.75-mm undercut depths exhibited greater initial retentive forces (3.15–3.51 N) compared to those in the 0.25-mm undercut group (2.40–2.80 N). Group I maintained consistent retentive forces over the cycles (<i>P</i> = 0.345), whereas Group II showed declining forces after the initial use (<i>P</i> &lt; 0.003). In both groups, the 0.50-mm undercut exhibited a greater retentive force than the 0.25-mm (<i>P</i> &lt; 0.001 and <i>P</i> &lt; 0.004, respectively), with no significant differences between the 0.50-mm and 0.75-mm undercut depths. Despite a lower initial retentive force, the 0.25-mm undercut showed less deformation and clasp tip wear.</p><p><b>Conclusions:</b> The PEKK clasps did not exhibit significantly reduced retentive forces or permanent deformations after 15,000 fatigue cycles. These results suggest that the PEKK polymer displays superior mechanical properties as an esthetic clasp material, and clasps with 0.50-mm and 0.75-mm undercut depths are recommended for long-term clinical use.</p>\\n<p></p>\",\"PeriodicalId\":16887,\"journal\":{\"name\":\"Journal of prosthodontic research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-01-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of prosthodontic research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2186/jpr.jpr_d_23_00080\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of prosthodontic research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.jpr_d_23_00080","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在探讨双Akers聚醚醚酮酮(PEKK)卡环在不同设计和切口深度的可摘局部义齿(RPD)上的固位力和变形:使用计算机辅助设计和计算机辅助制造(CAD/CAM)技术制作了 30 个具有两种不同宽度和高度的双 Akers' PEKK 卡环(I 组和 II 组)。每种设计又被细分(n = 5)为三种下切深度(0.25、0.50 和 0.75 毫米)。经过 10 年的临床使用(15,000 次插入/拔出循环)后,测量了卡环的固位力,并分析了循环前后卡环尖端的变形情况:结果:与切口深度为 0.25 毫米的组别(2.40-2.80 牛顿)相比,切口深度为 0.50 毫米和 0.75 毫米的组别表现出更大的初始牵引力(3.15-3.51 牛顿)。第一组在循环过程中保持了一致的牵引力(P = 0.345),而第二组在初次使用后牵引力有所下降(P < 0.003)。在两组中,0.50 毫米的切口比 0.25 毫米的切口显示出更大的牵引力(分别为 P < 0.001 和 P < 0.004),0.50 毫米和 0.75 毫米的切口深度之间没有显著差异。尽管初始保持力较低,但 0.25 毫米的切口变形和扣尖磨损较少:结论:PEKK 扣在经过 15,000 次疲劳循环后,保持力和永久变形并没有明显降低。这些结果表明,PEKK 聚合物作为一种美学卡环材料具有优异的机械性能,建议在临床上长期使用 0.50 毫米和 0.75 毫米切口深度的卡环。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In vitro study of optimal removable partial denture clasp design made from novel high-performance polyetherketoneketone

Purpose: This study aimed to investigate the retentive force and deformation of double Akers’ polyetherketoneketone (PEKK) clasps on removable partial dentures (RPDs) with varying designs and undercut depths.

Methods: Thirty double Akers’ PEKK clasps with two different widths and heights (Groups I and II) were fabricated using computer-aided design and computer-aided manufacturing (CAD/CAM). Each design was further subdivided (n = 5) into three undercut depths (0.25, 0.50, and 0.75 mm). The retentive force of the clasps was measured after 10 years of clinical use (15,000 insertion/removal cycles), and the deformation of the clasp tips was analyzed before and after cycling.

Results: Clasps with 0.50-mm and 0.75-mm undercut depths exhibited greater initial retentive forces (3.15–3.51 N) compared to those in the 0.25-mm undercut group (2.40–2.80 N). Group I maintained consistent retentive forces over the cycles (P = 0.345), whereas Group II showed declining forces after the initial use (P < 0.003). In both groups, the 0.50-mm undercut exhibited a greater retentive force than the 0.25-mm (P < 0.001 and P < 0.004, respectively), with no significant differences between the 0.50-mm and 0.75-mm undercut depths. Despite a lower initial retentive force, the 0.25-mm undercut showed less deformation and clasp tip wear.

Conclusions: The PEKK clasps did not exhibit significantly reduced retentive forces or permanent deformations after 15,000 fatigue cycles. These results suggest that the PEKK polymer displays superior mechanical properties as an esthetic clasp material, and clasps with 0.50-mm and 0.75-mm undercut depths are recommended for long-term clinical use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of prosthodontic research
Journal of prosthodontic research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
6.90
自引率
11.10%
发文量
161
期刊介绍: Journal of Prosthodontic Research is published 4 times annually, in January, April, July, and October, under supervision by the Editorial Board of Japan Prosthodontic Society, which selects all materials submitted for publication. Journal of Prosthodontic Research originated as an official journal of Japan Prosthodontic Society. It has recently developed a long-range plan to become the most prestigious Asian journal of dental research regarding all aspects of oral and occlusal rehabilitation, fixed/removable prosthodontics, oral implantology and applied oral biology and physiology. The Journal will cover all diagnostic and clinical management aspects necessary to reestablish subjective and objective harmonious oral aesthetics and function. The most-targeted topics: 1) Clinical Epidemiology and Prosthodontics 2) Fixed/Removable Prosthodontics 3) Oral Implantology 4) Prosthodontics-Related Biosciences (Regenerative Medicine, Bone Biology, Mechanobiology, Microbiology/Immunology) 5) Oral Physiology and Biomechanics (Masticating and Swallowing Function, Parafunction, e.g., bruxism) 6) Orofacial Pain and Temporomandibular Disorders (TMDs) 7) Adhesive Dentistry / Dental Materials / Aesthetic Dentistry 8) Maxillofacial Prosthodontics and Dysphagia Rehabilitation 9) Digital Dentistry Prosthodontic treatment may become necessary as a result of developmental or acquired disturbances in the orofacial region, of orofacial trauma, or of a variety of dental and oral diseases and orofacial pain conditions. Reviews, Original articles, technical procedure and case reports can be submitted. Letters to the Editor commenting on papers or any aspect of Journal of Prosthodontic Research are welcomed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信