{"title":"扫描策略对数字口内扫描仪准确性的影响:体外研究荟萃分析。","authors":"Louis Hardan, Rim Bourgi, Monika Lukomska-Szymanska, Juan Carlos Hernández-Cabanillas, Juan Eliezer Zamarripa-Calderón, Gilbert Jorquera, Sinan Ghishan, Carlos Enrique Cuevas-Suárez","doi":"10.4047/jap.2023.15.6.315","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an <i>in vitro</i> setting, through a systematic review and meta-analysis.</p><p><strong>Materials and methods: </strong>This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, <i>in vitro</i>. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on <i>in vitro</i> studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05.</p><p><strong>Results: </strong>The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (<i>P</i> < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (<i>P</i> ≤ 0.02) and when an S-shaped pattern was followed (<i>P</i> ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (<i>P</i> ≥ 0.16).</p><p><strong>Conclusion: </strong>The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10774636/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of <i>in vitro</i> studies.\",\"authors\":\"Louis Hardan, Rim Bourgi, Monika Lukomska-Szymanska, Juan Carlos Hernández-Cabanillas, Juan Eliezer Zamarripa-Calderón, Gilbert Jorquera, Sinan Ghishan, Carlos Enrique Cuevas-Suárez\",\"doi\":\"10.4047/jap.2023.15.6.315\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an <i>in vitro</i> setting, through a systematic review and meta-analysis.</p><p><strong>Materials and methods: </strong>This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, <i>in vitro</i>. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on <i>in vitro</i> studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05.</p><p><strong>Results: </strong>The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (<i>P</i> < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (<i>P</i> ≤ 0.02) and when an S-shaped pattern was followed (<i>P</i> ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (<i>P</i> ≥ 0.16).</p><p><strong>Conclusion: </strong>The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.</p>\",\"PeriodicalId\":51291,\"journal\":{\"name\":\"Journal of Advanced Prosthodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10774636/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4047/jap.2023.15.6.315\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2023.15.6.315","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/18 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在通过系统综述和荟萃分析,探讨在体外环境下,不同的扫描策略是否会影响口内扫描仪的准确性:本综述按照 PRISMA 2020 标准进行。采用了以下 PICOS 方法:人群,牙印;干预,使用与制造商说明不同的扫描策略的口内扫描仪;对照,按照制造商要求使用口内扫描仪;结果,口内扫描仪的准确性;研究类型,体外研究。我们在 Embase、SciELO、PubMed、Scopus 和 Web of Science 等多个数据库中进行了全面的文献检索。纳入标准以报告使用口内扫描仪进行数字印模的准确性的体外研究为基础。分析使用 Review Manager 软件(5.3.5 版;Cochrane Collaboration,丹麦哥本哈根)进行。使用基于随机效应模型的标准化平均差进行总体比较,显著性水平为 α = 0.05:荟萃分析包括 15 篇文章。在干燥条件下,数字印模的准确性明显提高(P < 0.001)。此外,使用人工地标(P ≤ 0.02)和遵循 S 形模式(P ≤ 0.01)时,印模的真实度和精确度都有所提高。然而,所使用的光线类型对数字口内扫描仪的精确度没有显著影响(P≥0.16):通过在干燥条件下使用人工地标和数字印模进行扫描,可以提高数字口内扫描仪的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies.

Purpose: This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis.

Materials and methods: This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05.

Results: The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16).

Conclusion: The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信