静脉移植适应症对游离皮瓣效果的影响

IF 2.2 3区 医学 Q2 SURGERY
Journal of reconstructive microsurgery Pub Date : 2024-09-01 Epub Date: 2024-01-08 DOI:10.1055/a-2240-1534
Michelle Coriddi, Leslie Kim, Kathryn Haglich, Jonas Nelson, Farooq Shahzad, Joseph Dayan, Joseph Disa, Babak Mehrara, Peter Cordeiro, Colleen McCarthy
{"title":"静脉移植适应症对游离皮瓣效果的影响","authors":"Michelle Coriddi, Leslie Kim, Kathryn Haglich, Jonas Nelson, Farooq Shahzad, Joseph Dayan, Joseph Disa, Babak Mehrara, Peter Cordeiro, Colleen McCarthy","doi":"10.1055/a-2240-1534","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong> Prior studies have shown an increased risk of complications and flap loss with the use of vein grafts in microsurgery. We hypothesize that indication for use of a vein graft can affect flap complications and loss rates.</p><p><strong>Methods: </strong> We performed a retrospective review of all patients at our institution from 2010 to 2020 who underwent free flap reconstruction and required use of a vein graft. Indications for vein grafting included: salvage of flap during primary operation after microvascular compromise, augmentation of flow during primary operation, lengthening of the flap pedicle during the primary operation, and salvage of the flap during a secondary salvage operation after microvascular compromise.</p><p><strong>Results: </strong> A total of 79 patients met the study inclusion criteria. There were significant differences among the vein graft indication groups and the following: area of reconstruction (<i>p</i> = 0.002), vein graft length (<i>p</i> = 0.018), vessels grafted (<i>p</i> = 0.001), vein graft donor site (<i>p</i> = 0.011), and total flap loss (<i>p</i> = 0.047). Of the four indications for vein grafting, salvage of the flap during secondary salvage operation after microvascular compromise had the highest rate of total flap loss (26.7%). There were no significant associations between other flap complications and vein graft indications.</p><p><strong>Conclusion: </strong> Vein graft use in the primary reconstructive setting is efficacious, with low risk of thrombosis. Use in secondary procedures, however, is associated with higher rates of total flap loss, likely due to the thrombotic process, which was initiated prior to the use of the graft resulting in the salvage procedure and not secondary to the graft itself.</p>","PeriodicalId":16949,"journal":{"name":"Journal of reconstructive microsurgery","volume":" ","pages":"535-541"},"PeriodicalIF":2.2000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparisons of Impact of Vein Grafting with Different Indications on Outcomes of Reconstruction with Free Flaps.\",\"authors\":\"Michelle Coriddi, Leslie Kim, Kathryn Haglich, Jonas Nelson, Farooq Shahzad, Joseph Dayan, Joseph Disa, Babak Mehrara, Peter Cordeiro, Colleen McCarthy\",\"doi\":\"10.1055/a-2240-1534\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong> Prior studies have shown an increased risk of complications and flap loss with the use of vein grafts in microsurgery. We hypothesize that indication for use of a vein graft can affect flap complications and loss rates.</p><p><strong>Methods: </strong> We performed a retrospective review of all patients at our institution from 2010 to 2020 who underwent free flap reconstruction and required use of a vein graft. Indications for vein grafting included: salvage of flap during primary operation after microvascular compromise, augmentation of flow during primary operation, lengthening of the flap pedicle during the primary operation, and salvage of the flap during a secondary salvage operation after microvascular compromise.</p><p><strong>Results: </strong> A total of 79 patients met the study inclusion criteria. There were significant differences among the vein graft indication groups and the following: area of reconstruction (<i>p</i> = 0.002), vein graft length (<i>p</i> = 0.018), vessels grafted (<i>p</i> = 0.001), vein graft donor site (<i>p</i> = 0.011), and total flap loss (<i>p</i> = 0.047). Of the four indications for vein grafting, salvage of the flap during secondary salvage operation after microvascular compromise had the highest rate of total flap loss (26.7%). There were no significant associations between other flap complications and vein graft indications.</p><p><strong>Conclusion: </strong> Vein graft use in the primary reconstructive setting is efficacious, with low risk of thrombosis. Use in secondary procedures, however, is associated with higher rates of total flap loss, likely due to the thrombotic process, which was initiated prior to the use of the graft resulting in the salvage procedure and not secondary to the graft itself.</p>\",\"PeriodicalId\":16949,\"journal\":{\"name\":\"Journal of reconstructive microsurgery\",\"volume\":\" \",\"pages\":\"535-541\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of reconstructive microsurgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2240-1534\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of reconstructive microsurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2240-1534","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

导言:先前的研究表明,在显微外科手术中使用静脉移植物会增加并发症和皮瓣脱落的风险。我们假设静脉移植的使用适应症会影响皮瓣并发症和损失率:我们对本机构 2010-2020 年期间接受游离皮瓣重建术并需要使用静脉移植的所有患者进行了回顾性研究。静脉移植的适应症包括:在微血管受损后的初次手术中挽救皮瓣;在初次手术中增加血流量;在初次手术中延长皮瓣蒂;在微血管受损后的二次挽救手术中挽救皮瓣:79名患者符合研究纳入标准。静脉移植适应症组与以下方面存在明显差异:重建面积(P=0.002)、静脉移植长度(P=0.018)、移植血管(P=0.001)、静脉移植供体部位(P=0.011)和皮瓣总损失(P=0.047)。在静脉移植的四个适应症中,微血管受损后二次抢救手术中的皮瓣挽救造成的皮瓣总脱落率最高(26.7%)。其他皮瓣并发症与静脉移植适应症之间没有明显关联:结论:在一级重建中使用静脉移植是有效的,血栓形成的风险较低。结论:在初次重建中使用静脉移植物疗效显著,血栓形成的风险较低,但在二次手术中使用静脉移植物,皮瓣完全脱落的比例较高,这可能是由于血栓形成过程在使用移植物之前就已开始,导致了抢救性手术,而非移植物本身的继发性原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparisons of Impact of Vein Grafting with Different Indications on Outcomes of Reconstruction with Free Flaps.

Background:  Prior studies have shown an increased risk of complications and flap loss with the use of vein grafts in microsurgery. We hypothesize that indication for use of a vein graft can affect flap complications and loss rates.

Methods:  We performed a retrospective review of all patients at our institution from 2010 to 2020 who underwent free flap reconstruction and required use of a vein graft. Indications for vein grafting included: salvage of flap during primary operation after microvascular compromise, augmentation of flow during primary operation, lengthening of the flap pedicle during the primary operation, and salvage of the flap during a secondary salvage operation after microvascular compromise.

Results:  A total of 79 patients met the study inclusion criteria. There were significant differences among the vein graft indication groups and the following: area of reconstruction (p = 0.002), vein graft length (p = 0.018), vessels grafted (p = 0.001), vein graft donor site (p = 0.011), and total flap loss (p = 0.047). Of the four indications for vein grafting, salvage of the flap during secondary salvage operation after microvascular compromise had the highest rate of total flap loss (26.7%). There were no significant associations between other flap complications and vein graft indications.

Conclusion:  Vein graft use in the primary reconstructive setting is efficacious, with low risk of thrombosis. Use in secondary procedures, however, is associated with higher rates of total flap loss, likely due to the thrombotic process, which was initiated prior to the use of the graft resulting in the salvage procedure and not secondary to the graft itself.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
28.60%
发文量
80
审稿时长
1 months
期刊介绍: The Journal of Reconstructive Microsurgery is a peer-reviewed, indexed journal that provides an international forum for the publication of articles focusing on reconstructive microsurgery and complex reconstructive surgery. The journal was originally established in 1984 for the microsurgical community to publish and share academic papers. The Journal of Reconstructive Microsurgery provides the latest in original research spanning basic laboratory, translational, and clinical investigations. Review papers cover current topics in complex reconstruction and microsurgery. In addition, special sections discuss new technologies, innovations, materials, and significant problem cases. The journal welcomes controversial topics, editorial comments, book reviews, and letters to the Editor, in order to complete the balanced spectrum of information available in the Journal of Reconstructive Microsurgery. All articles undergo stringent peer review by international experts in the specialty.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信