用猪模型训练超声引导经皮肾造瘘术。

IF 2.5 3区 医学 Q2 UROLOGY & NEPHROLOGY
Jae Yong Jeong, Dae Young Jun, Young Joon Moon, Dong Hyuk Kang, Hae Do Jung, Seung Hyun Jeon, Joo Yong Lee
{"title":"用猪模型训练超声引导经皮肾造瘘术。","authors":"Jae Yong Jeong, Dae Young Jun, Young Joon Moon, Dong Hyuk Kang, Hae Do Jung, Seung Hyun Jeon, Joo Yong Lee","doi":"10.4111/icu.20230298","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>There is increasing interest in the use of ultrasound for endoscopic and percutaneous procedures. Access can be achieved without radiation exposure under ultrasound guidance. Our aim was to develop a porcine-based training model for ultrasound-guided percutaneous renal access that could also be personalized to a specific patient.</p><p><strong>Materials and methods: </strong>The Institutional Animal Care and Use Committee of Severance Hospital approved the study protocol. An anesthetized pig was placed in the dorsal lithotomy position. For the nephrostomy puncture, a Chiba biopsy needle with an echo tip was used under ultrasound guidance. Eight residents and three consultants in urology participated. Puncture time was defined as the nephrostomy time to confirm the flow of irrigation via the needle. After training, satisfaction survey results for clinical usability and procedural difficulty were evaluated.</p><p><strong>Results: </strong>The 5-point Likert scale satisfaction survey for clinical usability and procedural difficulty found mean results of 4.64 and 4.09 points, respectively. There were no differences between residents and consultants for either variable. For all participants combined, there was a significant difference for nephrostomy time between the first and second trials (278.8±70.6 s vs. 244.5±47.0 s; p=0.007). The between-trial difference was greater for residents (291.5±71.2 s vs. 259.1±41.9 s; p=0.039). The difference for the consultant was not significant (245.0±69.4 s vs. 205.7±42.5 s; p=0.250).</p><p><strong>Conclusions: </strong>We developed a porcine-based ultrasound-guided nephrostomy puncture training model. Satisfaction survey results indicated high clinical usability and procedural difficulty. For nephrostomy time, the model was more effective for urology residents than for consultants.</p>","PeriodicalId":14522,"journal":{"name":"Investigative and Clinical Urology","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10789536/pdf/","citationCount":"0","resultStr":"{\"title\":\"Training ultrasound-guided percutaneous nephrostomy technique with porcine model.\",\"authors\":\"Jae Yong Jeong, Dae Young Jun, Young Joon Moon, Dong Hyuk Kang, Hae Do Jung, Seung Hyun Jeon, Joo Yong Lee\",\"doi\":\"10.4111/icu.20230298\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>There is increasing interest in the use of ultrasound for endoscopic and percutaneous procedures. Access can be achieved without radiation exposure under ultrasound guidance. Our aim was to develop a porcine-based training model for ultrasound-guided percutaneous renal access that could also be personalized to a specific patient.</p><p><strong>Materials and methods: </strong>The Institutional Animal Care and Use Committee of Severance Hospital approved the study protocol. An anesthetized pig was placed in the dorsal lithotomy position. For the nephrostomy puncture, a Chiba biopsy needle with an echo tip was used under ultrasound guidance. Eight residents and three consultants in urology participated. Puncture time was defined as the nephrostomy time to confirm the flow of irrigation via the needle. After training, satisfaction survey results for clinical usability and procedural difficulty were evaluated.</p><p><strong>Results: </strong>The 5-point Likert scale satisfaction survey for clinical usability and procedural difficulty found mean results of 4.64 and 4.09 points, respectively. There were no differences between residents and consultants for either variable. For all participants combined, there was a significant difference for nephrostomy time between the first and second trials (278.8±70.6 s vs. 244.5±47.0 s; p=0.007). The between-trial difference was greater for residents (291.5±71.2 s vs. 259.1±41.9 s; p=0.039). The difference for the consultant was not significant (245.0±69.4 s vs. 205.7±42.5 s; p=0.250).</p><p><strong>Conclusions: </strong>We developed a porcine-based ultrasound-guided nephrostomy puncture training model. Satisfaction survey results indicated high clinical usability and procedural difficulty. For nephrostomy time, the model was more effective for urology residents than for consultants.</p>\",\"PeriodicalId\":14522,\"journal\":{\"name\":\"Investigative and Clinical Urology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10789536/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Investigative and Clinical Urology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4111/icu.20230298\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative and Clinical Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4111/icu.20230298","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:人们对使用超声波进行内窥镜和经皮手术越来越感兴趣。在超声引导下,可在无辐射暴露的情况下实现入路。我们的目的是开发一种基于猪的超声引导经皮肾脏入路训练模型,该模型也可针对特定患者进行个性化设计:研究方案经 Severance 医院动物护理和使用委员会批准。将一只麻醉猪置于背侧截石位。在超声引导下使用带回声针头的千叶活检针进行肾穿刺。八名住院医师和三名泌尿科顾问参与了这项研究。穿刺时间被定义为肾造瘘时间,以确认通过针头的灌注流。培训结束后,对临床可用性和手术难度进行了满意度调查:结果:针对临床可用性和手术难度的 5 点李克特量表满意度调查的平均结果分别为 4.64 分和 4.09 分。住院医师和顾问在这两个变量上没有差异。在所有参与者中,第一次和第二次试验的肾造瘘时间存在显著差异(278.8±70.6 秒 vs 244.5±47.0 秒;P=0.007)。住院医师的试验间差异更大(291.5±71.2 秒 vs. 259.1±41.9 秒;P=0.039)。顾问的差异不显著(245.0±69.4 s vs. 205.7±42.5 s; p=0.250):我们开发了一种基于猪肝的超声引导肾造口术穿刺培训模型。满意度调查结果表明,该模型具有较高的临床实用性和操作难度。就肾造瘘时间而言,该模型对泌尿科住院医生比对顾问更有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Training ultrasound-guided percutaneous nephrostomy technique with porcine model.

Purpose: There is increasing interest in the use of ultrasound for endoscopic and percutaneous procedures. Access can be achieved without radiation exposure under ultrasound guidance. Our aim was to develop a porcine-based training model for ultrasound-guided percutaneous renal access that could also be personalized to a specific patient.

Materials and methods: The Institutional Animal Care and Use Committee of Severance Hospital approved the study protocol. An anesthetized pig was placed in the dorsal lithotomy position. For the nephrostomy puncture, a Chiba biopsy needle with an echo tip was used under ultrasound guidance. Eight residents and three consultants in urology participated. Puncture time was defined as the nephrostomy time to confirm the flow of irrigation via the needle. After training, satisfaction survey results for clinical usability and procedural difficulty were evaluated.

Results: The 5-point Likert scale satisfaction survey for clinical usability and procedural difficulty found mean results of 4.64 and 4.09 points, respectively. There were no differences between residents and consultants for either variable. For all participants combined, there was a significant difference for nephrostomy time between the first and second trials (278.8±70.6 s vs. 244.5±47.0 s; p=0.007). The between-trial difference was greater for residents (291.5±71.2 s vs. 259.1±41.9 s; p=0.039). The difference for the consultant was not significant (245.0±69.4 s vs. 205.7±42.5 s; p=0.250).

Conclusions: We developed a porcine-based ultrasound-guided nephrostomy puncture training model. Satisfaction survey results indicated high clinical usability and procedural difficulty. For nephrostomy time, the model was more effective for urology residents than for consultants.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
4.30%
发文量
82
审稿时长
4 weeks
期刊介绍: Investigative and Clinical Urology (Investig Clin Urol, ICUrology) is an international, peer-reviewed, platinum open access journal published bimonthly. ICUrology aims to provide outstanding scientific and clinical research articles, that will advance knowledge and understanding of urological diseases and current therapeutic treatments. ICUrology publishes Original Articles, Rapid Communications, Review Articles, Special Articles, Innovations in Urology, Editorials, and Letters to the Editor, with a focus on the following areas of expertise: • Precision Medicine in Urology • Urological Oncology • Robotics/Laparoscopy • Endourology/Urolithiasis • Lower Urinary Tract Dysfunction • Female Urology • Sexual Dysfunction/Infertility • Infection/Inflammation • Reconstruction/Transplantation • Geriatric Urology • Pediatric Urology • Basic/Translational Research One of the notable features of ICUrology is the application of multimedia platforms facilitating easy-to-access online video clips of newly developed surgical techniques from the journal''s website, by a QR (quick response) code located in the article, or via YouTube. ICUrology provides current and highly relevant knowledge to a broad audience at the cutting edge of urological research and clinical practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信