室内环境中的内毒素研究:在日本与马有关的设施中开展的研究

IF 1.1 Q4 METEOROLOGY & ATMOSPHERIC SCIENCES
Takeshi Ogasawara, Hoon Kim, Eunsu Lim
{"title":"室内环境中的内毒素研究:在日本与马有关的设施中开展的研究","authors":"Takeshi Ogasawara,&nbsp;Hoon Kim,&nbsp;Eunsu Lim","doi":"10.1007/s44273-023-00025-6","DOIUrl":null,"url":null,"abstract":"<div><p>In recent years, endotoxins have received considerable attention as substances associated with allergic diseases. Endotoxins are cell wall components of gram-negative bacteria that are widely present in the living environment. Endotoxin concentrations are particularly high in environments where animals are housed. However, while the status of endotoxin concentrations in the general environment is becoming clearer, there remains a scarcity of studies in environments with potentially higher concentrations.</p><p>In this study, we measured indoor endotoxin concentrations in buildings in Japan that are strongly associated with horses. The target buildings include a “Magariya,” an old Japanese house, an accommodation facility connected to a horse stable, and a stable specifically for thoroughbreds. Air and dust samples were collected at these measurement targets and analyzed for air and dust concentrations.</p><p>Airborne concentrations were higher in buildings with horses present than in buildings without horses, and the presence/absence of horses is thought to have a significant effect on the airborne concentration of endotoxin. Additionally, as the density of horses increases, endotoxin concentrations also tend to increase. Dust concentration had different values in different rooms even in the same building. These results suggest that dust concentrations may be affected by floor materials, frequency of cleaning, and frequency of human traffic from areas of high concentrations. Endotoxin concentrations were high in the stable during the work because of the replacement of the dried straw in the stalls and the removal of horse excrement. These results are expected to be useful in controlling endotoxin concentrations in indoor environments of various building types.</p></div>","PeriodicalId":45358,"journal":{"name":"Asian Journal of Atmospheric Environment","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s44273-023-00025-6.pdf","citationCount":"0","resultStr":"{\"title\":\"Study on endotoxin in indoor environment: research at equine-related facilities in Japan\",\"authors\":\"Takeshi Ogasawara,&nbsp;Hoon Kim,&nbsp;Eunsu Lim\",\"doi\":\"10.1007/s44273-023-00025-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In recent years, endotoxins have received considerable attention as substances associated with allergic diseases. Endotoxins are cell wall components of gram-negative bacteria that are widely present in the living environment. Endotoxin concentrations are particularly high in environments where animals are housed. However, while the status of endotoxin concentrations in the general environment is becoming clearer, there remains a scarcity of studies in environments with potentially higher concentrations.</p><p>In this study, we measured indoor endotoxin concentrations in buildings in Japan that are strongly associated with horses. The target buildings include a “Magariya,” an old Japanese house, an accommodation facility connected to a horse stable, and a stable specifically for thoroughbreds. Air and dust samples were collected at these measurement targets and analyzed for air and dust concentrations.</p><p>Airborne concentrations were higher in buildings with horses present than in buildings without horses, and the presence/absence of horses is thought to have a significant effect on the airborne concentration of endotoxin. Additionally, as the density of horses increases, endotoxin concentrations also tend to increase. Dust concentration had different values in different rooms even in the same building. These results suggest that dust concentrations may be affected by floor materials, frequency of cleaning, and frequency of human traffic from areas of high concentrations. Endotoxin concentrations were high in the stable during the work because of the replacement of the dried straw in the stalls and the removal of horse excrement. These results are expected to be useful in controlling endotoxin concentrations in indoor environments of various building types.</p></div>\",\"PeriodicalId\":45358,\"journal\":{\"name\":\"Asian Journal of Atmospheric Environment\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-01-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s44273-023-00025-6.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Atmospheric Environment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s44273-023-00025-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"METEOROLOGY & ATMOSPHERIC SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Atmospheric Environment","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1007/s44273-023-00025-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

近年来,内毒素作为与过敏性疾病相关的物质受到了广泛关注。内毒素是革兰氏阴性细菌的细胞壁成分,广泛存在于生活环境中。动物饲养环境中的内毒素浓度尤其高。在这项研究中,我们测量了日本与马密切相关的建筑物中的室内内毒素浓度。目标建筑包括 "Magariya"(一种古老的日本房屋)、与马厩相连的住宿设施以及专门饲养纯血马的马厩。在这些测量目标处采集了空气和灰尘样本,并对空气和灰尘的浓度进行了分析。有马的建筑物的空气传播浓度高于无马的建筑物,有马/无马被认为对空气传播的内毒素浓度有显著影响。此外,随着马匹密度的增加,内毒素浓度也会增加。即使在同一栋楼里,不同房间的粉尘浓度值也不尽相同。这些结果表明,灰尘浓度可能会受到地板材料、清洁频率和高浓度区域人流量频率的影响。由于更换了马厩中的干稻草,并清除了马的排泄物,因此工作期间马厩中的内毒素浓度较高。预计这些结果将有助于控制各类建筑室内环境中的内毒素浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study on endotoxin in indoor environment: research at equine-related facilities in Japan

In recent years, endotoxins have received considerable attention as substances associated with allergic diseases. Endotoxins are cell wall components of gram-negative bacteria that are widely present in the living environment. Endotoxin concentrations are particularly high in environments where animals are housed. However, while the status of endotoxin concentrations in the general environment is becoming clearer, there remains a scarcity of studies in environments with potentially higher concentrations.

In this study, we measured indoor endotoxin concentrations in buildings in Japan that are strongly associated with horses. The target buildings include a “Magariya,” an old Japanese house, an accommodation facility connected to a horse stable, and a stable specifically for thoroughbreds. Air and dust samples were collected at these measurement targets and analyzed for air and dust concentrations.

Airborne concentrations were higher in buildings with horses present than in buildings without horses, and the presence/absence of horses is thought to have a significant effect on the airborne concentration of endotoxin. Additionally, as the density of horses increases, endotoxin concentrations also tend to increase. Dust concentration had different values in different rooms even in the same building. These results suggest that dust concentrations may be affected by floor materials, frequency of cleaning, and frequency of human traffic from areas of high concentrations. Endotoxin concentrations were high in the stable during the work because of the replacement of the dried straw in the stalls and the removal of horse excrement. These results are expected to be useful in controlling endotoxin concentrations in indoor environments of various building types.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Asian Journal of Atmospheric Environment
Asian Journal of Atmospheric Environment METEOROLOGY & ATMOSPHERIC SCIENCES-
CiteScore
2.80
自引率
6.70%
发文量
22
审稿时长
21 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信