{"title":"体外机械循环支持选择标准化方案-左心室挑战方案的成果。","authors":"Naoki Tadokoro, Tetsuya Koyamoto, Kohei Tonai, Yuki Yoshida, Koudai Hirahsima, Satoshi Kainuma, Naonori Kawamoto, Kimito Minami, Hiroshi Nishioka, Tsukamoto Yasumasa, Tomoyuki Fujita, Satsuki Fukushima","doi":"10.1007/s10047-023-01427-7","DOIUrl":null,"url":null,"abstract":"<p><p>There are no criteria for surgical mechanical circulatory system (MCS) selection for acute heart failure. Since 2021, we have utilized cardiopulmonary bypass system to assess patients' heart and lung condition to inform surgical MCS selection. we aimed to retrospectively analyze the outcomes of treatments administered using our protocol. We analyzed the data of 19 patients who underwent surgical MCS implantation. We compared patients' characteristics across the biventricular-assist device (BiVAD), central Y-Y extracorporeal membrane oxygenation (ECMO), central ECMO, and left VAD (LVAD) systems. Patients' diagnoses included fulminant myocarditis (47.4%), dilated cardiomyopathy (21.1%), acute myocardial infarction (15.8%), infarction from aortic dissection (5.3%), doxorubicin-related cardiomyopathy (5.3%), and tachycardia-induced myocarditis (5.3%). Eight patients (42.1%) underwent LVAD implantation, 1 (5.2%) underwent central ECMO, 4 (21.1%) underwent BiVAD implantation, and 6 (31.6%) underwent central Y-Y ECMO. 48 h after surgery, both the pulmonary arterial and right atrial pressures were effectively controlled, with median values being 19.0 mmHg and 9.0 mmHg, respectively. No patients transitioned from LVAD to BiVAD in the delayed period. Cerebrovascular events occurred in 21.1%. Successful weaning was achieved in 11 patients (57.9%), and 5 patients (26.3%) were converted to durable LVAD. Two-year cumulative survival was 84.2%. Our protocol showed good results for device selection in patients with heart failure, and device selection according to this protocol enabled good control of the pulmonary and systemic circulations.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-01-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The outcomes of a standardized protocol for extracorporeal mechanical circulatory support selection-left ventricular challenge protocol.\",\"authors\":\"Naoki Tadokoro, Tetsuya Koyamoto, Kohei Tonai, Yuki Yoshida, Koudai Hirahsima, Satoshi Kainuma, Naonori Kawamoto, Kimito Minami, Hiroshi Nishioka, Tsukamoto Yasumasa, Tomoyuki Fujita, Satsuki Fukushima\",\"doi\":\"10.1007/s10047-023-01427-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>There are no criteria for surgical mechanical circulatory system (MCS) selection for acute heart failure. Since 2021, we have utilized cardiopulmonary bypass system to assess patients' heart and lung condition to inform surgical MCS selection. we aimed to retrospectively analyze the outcomes of treatments administered using our protocol. We analyzed the data of 19 patients who underwent surgical MCS implantation. We compared patients' characteristics across the biventricular-assist device (BiVAD), central Y-Y extracorporeal membrane oxygenation (ECMO), central ECMO, and left VAD (LVAD) systems. Patients' diagnoses included fulminant myocarditis (47.4%), dilated cardiomyopathy (21.1%), acute myocardial infarction (15.8%), infarction from aortic dissection (5.3%), doxorubicin-related cardiomyopathy (5.3%), and tachycardia-induced myocarditis (5.3%). Eight patients (42.1%) underwent LVAD implantation, 1 (5.2%) underwent central ECMO, 4 (21.1%) underwent BiVAD implantation, and 6 (31.6%) underwent central Y-Y ECMO. 48 h after surgery, both the pulmonary arterial and right atrial pressures were effectively controlled, with median values being 19.0 mmHg and 9.0 mmHg, respectively. No patients transitioned from LVAD to BiVAD in the delayed period. Cerebrovascular events occurred in 21.1%. Successful weaning was achieved in 11 patients (57.9%), and 5 patients (26.3%) were converted to durable LVAD. Two-year cumulative survival was 84.2%. Our protocol showed good results for device selection in patients with heart failure, and device selection according to this protocol enabled good control of the pulmonary and systemic circulations.</p>\",\"PeriodicalId\":15177,\"journal\":{\"name\":\"Journal of Artificial Organs\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-01-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10047-023-01427-7\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-023-01427-7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
The outcomes of a standardized protocol for extracorporeal mechanical circulatory support selection-left ventricular challenge protocol.
There are no criteria for surgical mechanical circulatory system (MCS) selection for acute heart failure. Since 2021, we have utilized cardiopulmonary bypass system to assess patients' heart and lung condition to inform surgical MCS selection. we aimed to retrospectively analyze the outcomes of treatments administered using our protocol. We analyzed the data of 19 patients who underwent surgical MCS implantation. We compared patients' characteristics across the biventricular-assist device (BiVAD), central Y-Y extracorporeal membrane oxygenation (ECMO), central ECMO, and left VAD (LVAD) systems. Patients' diagnoses included fulminant myocarditis (47.4%), dilated cardiomyopathy (21.1%), acute myocardial infarction (15.8%), infarction from aortic dissection (5.3%), doxorubicin-related cardiomyopathy (5.3%), and tachycardia-induced myocarditis (5.3%). Eight patients (42.1%) underwent LVAD implantation, 1 (5.2%) underwent central ECMO, 4 (21.1%) underwent BiVAD implantation, and 6 (31.6%) underwent central Y-Y ECMO. 48 h after surgery, both the pulmonary arterial and right atrial pressures were effectively controlled, with median values being 19.0 mmHg and 9.0 mmHg, respectively. No patients transitioned from LVAD to BiVAD in the delayed period. Cerebrovascular events occurred in 21.1%. Successful weaning was achieved in 11 patients (57.9%), and 5 patients (26.3%) were converted to durable LVAD. Two-year cumulative survival was 84.2%. Our protocol showed good results for device selection in patients with heart failure, and device selection according to this protocol enabled good control of the pulmonary and systemic circulations.
期刊介绍:
The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.