{"title":"防止在架设电线时发生工伤事故","authors":"Dar’ya S. Raspopina, Irina V. Volchatova","doi":"10.21285/2500-1582-2023-3-276-288","DOIUrl":null,"url":null,"abstract":"Recently, Russia has seen an increase in the number of people injured as a result of fatal occupational accidents. One of the traumatic industries is the electric power one. The article analyzes causes of electric shocks. Among 13 causes, the first place is occupied by direct contact with overhead power lines (46%). On the example of developed countries, examples of technical measures that can prevent industrial injuries when constructing power lines are provided. The main technical tool used in their construction is supports based on sectioned reinforced concrete racks. Its advantage is simplification. Reducing the installation time of reinforced concrete supports can decrease severity of the labor process, and concrete as a natural grounding conductor increases electrical safety.","PeriodicalId":322608,"journal":{"name":"XXI Century. Technosphere Safety","volume":"37 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PREVENTION OF OCCUPATIONAL INJURIES WHEN CONSTRUCTING POWER LINES\",\"authors\":\"Dar’ya S. Raspopina, Irina V. Volchatova\",\"doi\":\"10.21285/2500-1582-2023-3-276-288\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, Russia has seen an increase in the number of people injured as a result of fatal occupational accidents. One of the traumatic industries is the electric power one. The article analyzes causes of electric shocks. Among 13 causes, the first place is occupied by direct contact with overhead power lines (46%). On the example of developed countries, examples of technical measures that can prevent industrial injuries when constructing power lines are provided. The main technical tool used in their construction is supports based on sectioned reinforced concrete racks. Its advantage is simplification. Reducing the installation time of reinforced concrete supports can decrease severity of the labor process, and concrete as a natural grounding conductor increases electrical safety.\",\"PeriodicalId\":322608,\"journal\":{\"name\":\"XXI Century. Technosphere Safety\",\"volume\":\"37 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"XXI Century. Technosphere Safety\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21285/2500-1582-2023-3-276-288\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"XXI Century. Technosphere Safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21285/2500-1582-2023-3-276-288","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
PREVENTION OF OCCUPATIONAL INJURIES WHEN CONSTRUCTING POWER LINES
Recently, Russia has seen an increase in the number of people injured as a result of fatal occupational accidents. One of the traumatic industries is the electric power one. The article analyzes causes of electric shocks. Among 13 causes, the first place is occupied by direct contact with overhead power lines (46%). On the example of developed countries, examples of technical measures that can prevent industrial injuries when constructing power lines are provided. The main technical tool used in their construction is supports based on sectioned reinforced concrete racks. Its advantage is simplification. Reducing the installation time of reinforced concrete supports can decrease severity of the labor process, and concrete as a natural grounding conductor increases electrical safety.