基于饱和多孔介质理论的横向各向同性饱和土中桩基的水平振动

IF 1.2 Q2 MATHEMATICS, APPLIED
Linchao Liu, Qifang Yan
{"title":"基于饱和多孔介质理论的横向各向同性饱和土中桩基的水平振动","authors":"Linchao Liu, Qifang Yan","doi":"10.1155/2023/8103614","DOIUrl":null,"url":null,"abstract":"In order to consider the influence of liquid phase and soil anisotropy, the soil around the pile is considered a transversely isotropic saturated porous medium, and a horizontal dynamic model of transversely isotropic saturated soil-pile is established. Based on Beor’s saturated porous medium theory and the constitutive equation of transversely isotropic media, the horizontal dynamic control equation of transversely isotropic saturated soil is obtained without considering the vertical displacement. The horizontal vibration of transversely isotropic soil layers was solved using the potential function and separation of the variable method, and the horizontal and radial displacements of the solid soil skeleton of transversely isotropic saturated soil were obtained. The horizontal force of transversely isotropic saturated soil on a single pile was also obtained. On this basis, the horizontal dynamic equation of a single pile in transversely isotropic saturated soil was established, and the horizontal vibration of the pile foundation was solved using the initial parameter method, and the horizontal dynamic impedance of a single pile in transversely isotropic saturated soil is obtained. The influence of soil anisotropy parameter, liquid-solid coupling coefficient, diameter-length ratio, and modulus ratio on the horizontal dynamic impedance of a single pile in transversely isotropic saturated soil was analyzed through numerical examples. The analysis results show that the anisotropy parameters δ 1 , diameter-length ratio r 0 / H , and modulus ratio E p / C 66 have a significant impact on the horizontal dynamic impedance of pile foundation in transversely isotropic saturated soil, and the influence of anisotropy on the horizontal vibration of pile foundation should not be ignored. The influence of the liquid-solid coupling coefficient on the horizontal dynamic impedance factor is related to frequency to a certain extent.","PeriodicalId":49251,"journal":{"name":"Journal of Applied Mathematics","volume":"14 1","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2023-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Horizontal Vibration of Pile in Transversely Isotropic Saturated Soil Based on Saturated Porous Medium Theory\",\"authors\":\"Linchao Liu, Qifang Yan\",\"doi\":\"10.1155/2023/8103614\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to consider the influence of liquid phase and soil anisotropy, the soil around the pile is considered a transversely isotropic saturated porous medium, and a horizontal dynamic model of transversely isotropic saturated soil-pile is established. Based on Beor’s saturated porous medium theory and the constitutive equation of transversely isotropic media, the horizontal dynamic control equation of transversely isotropic saturated soil is obtained without considering the vertical displacement. The horizontal vibration of transversely isotropic soil layers was solved using the potential function and separation of the variable method, and the horizontal and radial displacements of the solid soil skeleton of transversely isotropic saturated soil were obtained. The horizontal force of transversely isotropic saturated soil on a single pile was also obtained. On this basis, the horizontal dynamic equation of a single pile in transversely isotropic saturated soil was established, and the horizontal vibration of the pile foundation was solved using the initial parameter method, and the horizontal dynamic impedance of a single pile in transversely isotropic saturated soil is obtained. The influence of soil anisotropy parameter, liquid-solid coupling coefficient, diameter-length ratio, and modulus ratio on the horizontal dynamic impedance of a single pile in transversely isotropic saturated soil was analyzed through numerical examples. The analysis results show that the anisotropy parameters δ 1 , diameter-length ratio r 0 / H , and modulus ratio E p / C 66 have a significant impact on the horizontal dynamic impedance of pile foundation in transversely isotropic saturated soil, and the influence of anisotropy on the horizontal vibration of pile foundation should not be ignored. The influence of the liquid-solid coupling coefficient on the horizontal dynamic impedance factor is related to frequency to a certain extent.\",\"PeriodicalId\":49251,\"journal\":{\"name\":\"Journal of Applied Mathematics\",\"volume\":\"14 1\",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Mathematics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/8103614\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATHEMATICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Mathematics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2023/8103614","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATHEMATICS, APPLIED","Score":null,"Total":0}
引用次数: 0

摘要

为了考虑液相和土体各向异性的影响,将桩周围的土体视为横向各向同性饱和多孔介质,并建立了横向各向同性饱和土-桩的水平动力模型。基于 Beor 饱和多孔介质理论和横向各向同性介质的构成方程,在不考虑竖向位移的情况下,得到了横向各向同性饱和土的水平动力控制方程。利用势函数和变量分离法求解了横向各向同性土层的水平振动,得到了横向各向同性饱和土固体土骨架的水平位移和径向位移。同时还得到了横向各向同性饱和土对单根桩的水平力。在此基础上,建立了横向各向同性饱和土中单桩的水平动力方程,并利用初始参数法求解了桩基的水平振动,得到了横向各向同性饱和土中单桩的水平动力阻抗。通过数值实例分析了土体各向异性参数、液固耦合系数、径长比和模量比对横向各向同性饱和土中单桩水平动阻抗的影响。分析结果表明,各向异性参数 δ 1、径长比 r 0 / H 和模量比 E p / C 66 对横向各向同性饱和土中桩基的水平动阻抗有显著影响,各向异性对桩基水平振动的影响不容忽视。液固耦合系数对水平动阻抗系数的影响在一定程度上与频率有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Horizontal Vibration of Pile in Transversely Isotropic Saturated Soil Based on Saturated Porous Medium Theory
In order to consider the influence of liquid phase and soil anisotropy, the soil around the pile is considered a transversely isotropic saturated porous medium, and a horizontal dynamic model of transversely isotropic saturated soil-pile is established. Based on Beor’s saturated porous medium theory and the constitutive equation of transversely isotropic media, the horizontal dynamic control equation of transversely isotropic saturated soil is obtained without considering the vertical displacement. The horizontal vibration of transversely isotropic soil layers was solved using the potential function and separation of the variable method, and the horizontal and radial displacements of the solid soil skeleton of transversely isotropic saturated soil were obtained. The horizontal force of transversely isotropic saturated soil on a single pile was also obtained. On this basis, the horizontal dynamic equation of a single pile in transversely isotropic saturated soil was established, and the horizontal vibration of the pile foundation was solved using the initial parameter method, and the horizontal dynamic impedance of a single pile in transversely isotropic saturated soil is obtained. The influence of soil anisotropy parameter, liquid-solid coupling coefficient, diameter-length ratio, and modulus ratio on the horizontal dynamic impedance of a single pile in transversely isotropic saturated soil was analyzed through numerical examples. The analysis results show that the anisotropy parameters δ 1 , diameter-length ratio r 0 / H , and modulus ratio E p / C 66 have a significant impact on the horizontal dynamic impedance of pile foundation in transversely isotropic saturated soil, and the influence of anisotropy on the horizontal vibration of pile foundation should not be ignored. The influence of the liquid-solid coupling coefficient on the horizontal dynamic impedance factor is related to frequency to a certain extent.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Applied Mathematics
Journal of Applied Mathematics MATHEMATICS, APPLIED-
CiteScore
2.70
自引率
0.00%
发文量
58
审稿时长
3.2 months
期刊介绍: Journal of Applied Mathematics is a refereed journal devoted to the publication of original research papers and review articles in all areas of applied, computational, and industrial mathematics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信