{"title":"利用 SnS2 传感器阵列响应的交互分析同时检测 CO 和 NO2 气体","authors":"Srinivasulu Kanaparthi, S. Singh","doi":"10.1149/2754-2726/ad0cd6","DOIUrl":null,"url":null,"abstract":"Developing a multi-analyte gas sensing system that simultaneously detects trace levels of CO and NO2 at low temperatures is necessary for the Internet of Things (IoT) based air quality monitoring applications. Nevertheless, gas sensors operating at low temperatures are nonspecific and rarely detect target gases at lower ppb levels in the air. Herein, an array of two SnS2 sensors with different bias voltages has been developed and characterized upon exposure to individual and binary mixtures of CO and NO2 gases at different concentrations. The developed gas sensors array achieved the lower detection limit of 45 ppb for NO2 and 150 ppb for CO. Further, co-adsorption-induced interaction analysis was carried out to predict the target gas concentration in the binary mixture using the mixed gas response. The mean absolute percentage error of 7.86% is observed in predicting the target gas concentrations in the binary mixture, which indicates the high prediction accuracy of proposed method. As a minimal resource intensive approach, the proposed method can be used in air quality monitoring applications that require low-power and low-cost sensors.","PeriodicalId":72870,"journal":{"name":"ECS sensors plus","volume":"160 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous Detection of CO and NO2 Gases using Interaction Analysis of SnS2 Sensor Array Response\",\"authors\":\"Srinivasulu Kanaparthi, S. Singh\",\"doi\":\"10.1149/2754-2726/ad0cd6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Developing a multi-analyte gas sensing system that simultaneously detects trace levels of CO and NO2 at low temperatures is necessary for the Internet of Things (IoT) based air quality monitoring applications. Nevertheless, gas sensors operating at low temperatures are nonspecific and rarely detect target gases at lower ppb levels in the air. Herein, an array of two SnS2 sensors with different bias voltages has been developed and characterized upon exposure to individual and binary mixtures of CO and NO2 gases at different concentrations. The developed gas sensors array achieved the lower detection limit of 45 ppb for NO2 and 150 ppb for CO. Further, co-adsorption-induced interaction analysis was carried out to predict the target gas concentration in the binary mixture using the mixed gas response. The mean absolute percentage error of 7.86% is observed in predicting the target gas concentrations in the binary mixture, which indicates the high prediction accuracy of proposed method. As a minimal resource intensive approach, the proposed method can be used in air quality monitoring applications that require low-power and low-cost sensors.\",\"PeriodicalId\":72870,\"journal\":{\"name\":\"ECS sensors plus\",\"volume\":\"160 12\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ECS sensors plus\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1149/2754-2726/ad0cd6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECS sensors plus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1149/2754-2726/ad0cd6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Simultaneous Detection of CO and NO2 Gases using Interaction Analysis of SnS2 Sensor Array Response
Developing a multi-analyte gas sensing system that simultaneously detects trace levels of CO and NO2 at low temperatures is necessary for the Internet of Things (IoT) based air quality monitoring applications. Nevertheless, gas sensors operating at low temperatures are nonspecific and rarely detect target gases at lower ppb levels in the air. Herein, an array of two SnS2 sensors with different bias voltages has been developed and characterized upon exposure to individual and binary mixtures of CO and NO2 gases at different concentrations. The developed gas sensors array achieved the lower detection limit of 45 ppb for NO2 and 150 ppb for CO. Further, co-adsorption-induced interaction analysis was carried out to predict the target gas concentration in the binary mixture using the mixed gas response. The mean absolute percentage error of 7.86% is observed in predicting the target gas concentrations in the binary mixture, which indicates the high prediction accuracy of proposed method. As a minimal resource intensive approach, the proposed method can be used in air quality monitoring applications that require low-power and low-cost sensors.