用于测量 ExoMars Trace Gas Orbiter 上宇宙辐射的柳林-MO 仪器的数值模拟

K. Krastev, J. Semkova, Rositza Koleva
{"title":"用于测量 ExoMars Trace Gas Orbiter 上宇宙辐射的柳林-MO 仪器的数值模拟","authors":"K. Krastev, J. Semkova, Rositza Koleva","doi":"10.7546/crabs.2023.11.07","DOIUrl":null,"url":null,"abstract":"We present the results from numerical simulation of Liulin-MO instrument for measurement of the space radiation on board Trace Gas Orbiter (TGO) satellite of ExoMars-2016 mission during its transit to Mars in April-September 2016 [Semkova J., T. Dachev, St. Maltchev, B. Tomov, Yu. Matviichuk} et al. (2015) Radiation environment investigations during ExoMars mission to Mars – objectives, experiments and instrumentation, C. R. Acad. Bulg. Sci., 68 (4), 485–496] [Semkova J., R. Koleva, V. Benghin, T. Dachev, Yu. Matviichuk et al. (2018) Charged particles radiation measurements with Liulin-MO dosimeter of FREND instrument aboard ExoMars Trace Gas Orbiter during the transit and in high elliptic Mars orbit, Icarus, 303, 53–66], using the Geant4 package. The methodology for calculating galactic cosmic rays (GCR) linear energy transfer (LET) is described. A methodology for screening false signals in the deposited energy spectra in the Liulin-MO detectors and correspondingly LET spectra is proposed. The contribution of the individual components of the spectrum of GCR in the LET spectrum is estimated. The calculated average radiation quality factor of GCR using the cleaned from false signals LET spectrum is compared with the experimental results obtained during the transit to Mars and a reasonable agreement is observed.","PeriodicalId":104760,"journal":{"name":"Proceedings of the Bulgarian Academy of Sciences","volume":"67 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical Simulation of Liulin-MO Instrument for Measuring Cosmic Radiation Onboard ExoMars Trace Gas Orbiter\",\"authors\":\"K. Krastev, J. Semkova, Rositza Koleva\",\"doi\":\"10.7546/crabs.2023.11.07\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present the results from numerical simulation of Liulin-MO instrument for measurement of the space radiation on board Trace Gas Orbiter (TGO) satellite of ExoMars-2016 mission during its transit to Mars in April-September 2016 [Semkova J., T. Dachev, St. Maltchev, B. Tomov, Yu. Matviichuk} et al. (2015) Radiation environment investigations during ExoMars mission to Mars – objectives, experiments and instrumentation, C. R. Acad. Bulg. Sci., 68 (4), 485–496] [Semkova J., R. Koleva, V. Benghin, T. Dachev, Yu. Matviichuk et al. (2018) Charged particles radiation measurements with Liulin-MO dosimeter of FREND instrument aboard ExoMars Trace Gas Orbiter during the transit and in high elliptic Mars orbit, Icarus, 303, 53–66], using the Geant4 package. The methodology for calculating galactic cosmic rays (GCR) linear energy transfer (LET) is described. A methodology for screening false signals in the deposited energy spectra in the Liulin-MO detectors and correspondingly LET spectra is proposed. The contribution of the individual components of the spectrum of GCR in the LET spectrum is estimated. The calculated average radiation quality factor of GCR using the cleaned from false signals LET spectrum is compared with the experimental results obtained during the transit to Mars and a reasonable agreement is observed.\",\"PeriodicalId\":104760,\"journal\":{\"name\":\"Proceedings of the Bulgarian Academy of Sciences\",\"volume\":\"67 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Bulgarian Academy of Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7546/crabs.2023.11.07\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Bulgarian Academy of Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7546/crabs.2023.11.07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们介绍了用于测量 2016 年 4 月至 9 月 ExoMars-2016 火星任务 Trace Gas Orbiter (TGO) 卫星在火星过境期间的空间辐射的 Liulin-MO 仪器的数值模拟结果[Semkova J., T. Dachev, St. Maltchev, B. Tomov, Yu.Matviichuk} 等人 (2015) ExoMars 火星任务期间的辐射环境调查 - 目标、实验和仪器,C. R. Acad.Bulg.科学》,68 (4),485-496] [Semkova J., R., R., M., et al.[Semkova J., R. Koleva, V. Benghin, T. Dachev, Yu. Matviichuk et al.Matviichuk 等人(2018 年)利用 Geant4 软件包,使用 ExoMars Trace Gas Orbiter 上 FREND 仪器的 Liulin-MO 剂量计对火星过境期间和高椭圆火星轨道上的带电粒子辐射进行测量,Icarus, 303, 53-66]。介绍了计算银河宇宙射线(GCR)线性能量传递(LET)的方法。提出了在柳林-MO 探测器沉积能谱和相应的 LET 能谱中筛选虚假信号的方法。估算了 GCR 频谱的各个成分对 LET 频谱的贡献。利用从虚假信号 LET 频谱中筛选出的 GCR 平均辐射品质因数与火星过境期间获得的实验结果进行了比较,结果显示两者吻合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Numerical Simulation of Liulin-MO Instrument for Measuring Cosmic Radiation Onboard ExoMars Trace Gas Orbiter
We present the results from numerical simulation of Liulin-MO instrument for measurement of the space radiation on board Trace Gas Orbiter (TGO) satellite of ExoMars-2016 mission during its transit to Mars in April-September 2016 [Semkova J., T. Dachev, St. Maltchev, B. Tomov, Yu. Matviichuk} et al. (2015) Radiation environment investigations during ExoMars mission to Mars – objectives, experiments and instrumentation, C. R. Acad. Bulg. Sci., 68 (4), 485–496] [Semkova J., R. Koleva, V. Benghin, T. Dachev, Yu. Matviichuk et al. (2018) Charged particles radiation measurements with Liulin-MO dosimeter of FREND instrument aboard ExoMars Trace Gas Orbiter during the transit and in high elliptic Mars orbit, Icarus, 303, 53–66], using the Geant4 package. The methodology for calculating galactic cosmic rays (GCR) linear energy transfer (LET) is described. A methodology for screening false signals in the deposited energy spectra in the Liulin-MO detectors and correspondingly LET spectra is proposed. The contribution of the individual components of the spectrum of GCR in the LET spectrum is estimated. The calculated average radiation quality factor of GCR using the cleaned from false signals LET spectrum is compared with the experimental results obtained during the transit to Mars and a reasonable agreement is observed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信