{"title":"考虑土-结构相互作用的结构高度对相邻结构地震响应的影响","authors":"Mohammed Abdulaziz, M. Hamood, Mohammed Fattah","doi":"10.30684/etj.2023.143892.1614","DOIUrl":null,"url":null,"abstract":"the dynamic behavior between two adjacent steel structures rested on sand soil. This study employed four novel small-scale multi-degree-of-freedom steel structure models: three, four, and five-story steel structures against a three-story steel structure. The results indicated that the tallest building had the maximum effect on the shorter one, especially on the top displacement with a peak value of 3.82 mm, top acceleration with a peak value of about 0.2 g, and foundation rotation with a peak value of around 1 degree. However, the effect of the structure height has a reverse impact on the soil pressure beneath the foundation of the shortest structure since the largest pressure response was recorded for the effect of the shortest similar adjacent building with a peak value of 8.8 kPa. In comparison, the highest building has the lowest effect on the shortest building, with a peak value of 6 k Pa.","PeriodicalId":507832,"journal":{"name":"Engineering and Technology Journal","volume":" 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Structure Height on Seismic Response of Adjacent Structures Considering Soil-Structure Interaction\",\"authors\":\"Mohammed Abdulaziz, M. Hamood, Mohammed Fattah\",\"doi\":\"10.30684/etj.2023.143892.1614\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"the dynamic behavior between two adjacent steel structures rested on sand soil. This study employed four novel small-scale multi-degree-of-freedom steel structure models: three, four, and five-story steel structures against a three-story steel structure. The results indicated that the tallest building had the maximum effect on the shorter one, especially on the top displacement with a peak value of 3.82 mm, top acceleration with a peak value of about 0.2 g, and foundation rotation with a peak value of around 1 degree. However, the effect of the structure height has a reverse impact on the soil pressure beneath the foundation of the shortest structure since the largest pressure response was recorded for the effect of the shortest similar adjacent building with a peak value of 8.8 kPa. In comparison, the highest building has the lowest effect on the shortest building, with a peak value of 6 k Pa.\",\"PeriodicalId\":507832,\"journal\":{\"name\":\"Engineering and Technology Journal\",\"volume\":\" 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Engineering and Technology Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30684/etj.2023.143892.1614\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering and Technology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30684/etj.2023.143892.1614","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of Structure Height on Seismic Response of Adjacent Structures Considering Soil-Structure Interaction
the dynamic behavior between two adjacent steel structures rested on sand soil. This study employed four novel small-scale multi-degree-of-freedom steel structure models: three, four, and five-story steel structures against a three-story steel structure. The results indicated that the tallest building had the maximum effect on the shorter one, especially on the top displacement with a peak value of 3.82 mm, top acceleration with a peak value of about 0.2 g, and foundation rotation with a peak value of around 1 degree. However, the effect of the structure height has a reverse impact on the soil pressure beneath the foundation of the shortest structure since the largest pressure response was recorded for the effect of the shortest similar adjacent building with a peak value of 8.8 kPa. In comparison, the highest building has the lowest effect on the shortest building, with a peak value of 6 k Pa.