{"title":"既有建筑安装后电梯井道的整体和局部风荷载","authors":"Haowen You, Chenxu Si, Xinwen Ma, Jingmiao Shang","doi":"10.3390/buildings14010110","DOIUrl":null,"url":null,"abstract":"The glass curtain walls of post-installed elevator shafts in existing buildings can be damaged by local wind loads, and the serviceability of an elevator may be affected by excessive overall wind loads, especially in hurricane-prone areas. The overall and local wind load characteristics of elevator shafts with different arrangements (E-type, H-type, I-type) were studied using wind tunnel tests and computational fluid dynamics (CFD) numerical simulations. Firstly, high-frequency base balance wind tunnel tests of these elevator shafts with three arrangements were carried out to obtain the overall wind loads on the elevator shafts. Secondly, a CFD simulation was performed on the post-installed elevator shafts with three arrangements, obtaining the surface local wind pressure distribution of the elevator shafts under different wind directions. Finally, the wind-induced displacement responses of post-installed elevator shafts were analyzed. The results show that the aerodynamic interference of different elevator arrangements (E-type, H-type, I-type) and wind directions have significant effects on the overall local wind loads and wind-induced responses of the post-installed elevator, while the local wind loads on the area of the elevator door are less influenced by the elevator arrangement type than local wind loads on the surface and the overall wind loads of the elevator shafts. The results and conclusions may be helpful for developing the wind-resistant design of a post-installed elevator shaft.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"113 47","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Overall and Local Wind Loads on Post-Installed Elevator Shaft of Existing Buildings\",\"authors\":\"Haowen You, Chenxu Si, Xinwen Ma, Jingmiao Shang\",\"doi\":\"10.3390/buildings14010110\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The glass curtain walls of post-installed elevator shafts in existing buildings can be damaged by local wind loads, and the serviceability of an elevator may be affected by excessive overall wind loads, especially in hurricane-prone areas. The overall and local wind load characteristics of elevator shafts with different arrangements (E-type, H-type, I-type) were studied using wind tunnel tests and computational fluid dynamics (CFD) numerical simulations. Firstly, high-frequency base balance wind tunnel tests of these elevator shafts with three arrangements were carried out to obtain the overall wind loads on the elevator shafts. Secondly, a CFD simulation was performed on the post-installed elevator shafts with three arrangements, obtaining the surface local wind pressure distribution of the elevator shafts under different wind directions. Finally, the wind-induced displacement responses of post-installed elevator shafts were analyzed. The results show that the aerodynamic interference of different elevator arrangements (E-type, H-type, I-type) and wind directions have significant effects on the overall local wind loads and wind-induced responses of the post-installed elevator, while the local wind loads on the area of the elevator door are less influenced by the elevator arrangement type than local wind loads on the surface and the overall wind loads of the elevator shafts. The results and conclusions may be helpful for developing the wind-resistant design of a post-installed elevator shaft.\",\"PeriodicalId\":48546,\"journal\":{\"name\":\"Buildings\",\"volume\":\"113 47\",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2023-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Buildings\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/buildings14010110\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Buildings","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/buildings14010110","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Overall and Local Wind Loads on Post-Installed Elevator Shaft of Existing Buildings
The glass curtain walls of post-installed elevator shafts in existing buildings can be damaged by local wind loads, and the serviceability of an elevator may be affected by excessive overall wind loads, especially in hurricane-prone areas. The overall and local wind load characteristics of elevator shafts with different arrangements (E-type, H-type, I-type) were studied using wind tunnel tests and computational fluid dynamics (CFD) numerical simulations. Firstly, high-frequency base balance wind tunnel tests of these elevator shafts with three arrangements were carried out to obtain the overall wind loads on the elevator shafts. Secondly, a CFD simulation was performed on the post-installed elevator shafts with three arrangements, obtaining the surface local wind pressure distribution of the elevator shafts under different wind directions. Finally, the wind-induced displacement responses of post-installed elevator shafts were analyzed. The results show that the aerodynamic interference of different elevator arrangements (E-type, H-type, I-type) and wind directions have significant effects on the overall local wind loads and wind-induced responses of the post-installed elevator, while the local wind loads on the area of the elevator door are less influenced by the elevator arrangement type than local wind loads on the surface and the overall wind loads of the elevator shafts. The results and conclusions may be helpful for developing the wind-resistant design of a post-installed elevator shaft.
期刊介绍:
BUILDINGS content is primarily staff-written and submitted information is evaluated by the editors for its value to the audience. Such information may be used in articles with appropriate attribution to the source. The editorial staff considers information on the following topics: -Issues directed at building owners and facility managers in North America -Issues relevant to existing buildings, including retrofits, maintenance and modernization -Solution-based content, such as tips and tricks -New construction but only with an eye to issues involving maintenance and operation We generally do not review the following topics because these are not relevant to our readers: -Information on the residential market with the exception of multifamily buildings -International news unrelated to the North American market -Real estate market updates or construction updates