利用大腿佩戴式惯性测量单元和关节角度信息的新型步态事件检测算法

IF 1.7 4区 医学 Q4 BIOPHYSICS
Jacob A Strick, Ryan J Farris, Jerzy T Sawicki
{"title":"利用大腿佩戴式惯性测量单元和关节角度信息的新型步态事件检测算法","authors":"Jacob A Strick, Ryan J Farris, Jerzy T Sawicki","doi":"10.1115/1.4064435","DOIUrl":null,"url":null,"abstract":"<p><p>This paper describes the development and evaluation of a novel, threshold-based gait event detection algorithm utilizing only one thigh inertial measurement unit (IMU) and unilateral, sagittal plane hip and knee joint angles. The algorithm was designed to detect heel strike (HS) and toe off (TO) gait events, with the eventual goal of detection in a real-time exoskeletal control system. The data used in the development and evaluation of the algorithm were obtained from two gait databases, each containing synchronized IMU and ground reaction force (GRF) data. All database subjects were healthy individuals walking in either a level-ground, urban environment or a treadmill lab environment. Inertial measurements used were three-dimensional thigh accelerations and three-dimensional thigh angular velocities. Parameters for the TO algorithm were identified on a per-subject basis. The GRF data were utilized to validate the algorithm's timing accuracy and quantify the fidelity of the algorithm, measured by the F1-Score. Across all participants, the algorithm reported a mean timing error of -41±20 ms with an F1-Score of 0.988 for HS. For TO, the algorithm reported a mean timing error of -1.4±21 ms with an F1-Score of 0.991. The results of this evaluation suggest that this algorithm is a promising solution to inertial based gait event detection; however, further refinement and real-time evaluation are required for use in exoskeletal control.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Novel Gait Event Detection Algorithm Using a Thigh-Worn Inertial Measurement Unit and Joint Angle Information.\",\"authors\":\"Jacob A Strick, Ryan J Farris, Jerzy T Sawicki\",\"doi\":\"10.1115/1.4064435\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper describes the development and evaluation of a novel, threshold-based gait event detection algorithm utilizing only one thigh inertial measurement unit (IMU) and unilateral, sagittal plane hip and knee joint angles. The algorithm was designed to detect heel strike (HS) and toe off (TO) gait events, with the eventual goal of detection in a real-time exoskeletal control system. The data used in the development and evaluation of the algorithm were obtained from two gait databases, each containing synchronized IMU and ground reaction force (GRF) data. All database subjects were healthy individuals walking in either a level-ground, urban environment or a treadmill lab environment. Inertial measurements used were three-dimensional thigh accelerations and three-dimensional thigh angular velocities. Parameters for the TO algorithm were identified on a per-subject basis. The GRF data were utilized to validate the algorithm's timing accuracy and quantify the fidelity of the algorithm, measured by the F1-Score. Across all participants, the algorithm reported a mean timing error of -41±20 ms with an F1-Score of 0.988 for HS. For TO, the algorithm reported a mean timing error of -1.4±21 ms with an F1-Score of 0.991. The results of this evaluation suggest that this algorithm is a promising solution to inertial based gait event detection; however, further refinement and real-time evaluation are required for use in exoskeletal control.</p>\",\"PeriodicalId\":54871,\"journal\":{\"name\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4064435\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4064435","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种基于阈值的新型步态事件检测算法的开发和评估,该算法仅利用一个大腿惯性测量单元(IMU)和单侧矢状面髋关节和膝关节角度。该算法旨在检测脚跟着地(HS)和脚趾离开(TO)步态事件,最终目标是在实时外骨骼控制系统中进行检测。用于开发和评估该算法的数据来自两个步态数据库,每个数据库都包含同步 IMU 和地面反作用力 (GRF) 数据。所有数据库对象都是在平地、城市环境或跑步机实验室环境中行走的健康人。惯性测量使用的是三维大腿加速度和三维大腿角速度。TO 算法的参数按每个受试者确定。利用 GRF 数据来验证算法的计时准确性,并通过 F1 分数来量化算法的保真度。在所有参与者中,HS 算法报告的平均计时误差为 -41 ± 20 毫秒,F1 分数为 0.988。对于 TO,该算法报告的平均计时误差为-1.4 ± 21 毫秒,F1 分数为 0.991。评估结果表明,该算法是基于惯性的步态事件检测的一个很有前途的解决方案;但是,要在外骨骼控制中使用,还需要进一步的改进和实时评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Novel Gait Event Detection Algorithm Using a Thigh-Worn Inertial Measurement Unit and Joint Angle Information.

This paper describes the development and evaluation of a novel, threshold-based gait event detection algorithm utilizing only one thigh inertial measurement unit (IMU) and unilateral, sagittal plane hip and knee joint angles. The algorithm was designed to detect heel strike (HS) and toe off (TO) gait events, with the eventual goal of detection in a real-time exoskeletal control system. The data used in the development and evaluation of the algorithm were obtained from two gait databases, each containing synchronized IMU and ground reaction force (GRF) data. All database subjects were healthy individuals walking in either a level-ground, urban environment or a treadmill lab environment. Inertial measurements used were three-dimensional thigh accelerations and three-dimensional thigh angular velocities. Parameters for the TO algorithm were identified on a per-subject basis. The GRF data were utilized to validate the algorithm's timing accuracy and quantify the fidelity of the algorithm, measured by the F1-Score. Across all participants, the algorithm reported a mean timing error of -41±20 ms with an F1-Score of 0.988 for HS. For TO, the algorithm reported a mean timing error of -1.4±21 ms with an F1-Score of 0.991. The results of this evaluation suggest that this algorithm is a promising solution to inertial based gait event detection; however, further refinement and real-time evaluation are required for use in exoskeletal control.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
169
审稿时长
4-8 weeks
期刊介绍: Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信