Volker Lauenroth, Armin Zittermann, Stefan Lucke, Jan F Gummert, Michiel Morshuis
{"title":"根据左心室辅助装置植入者的干线定位确定干线感染。","authors":"Volker Lauenroth, Armin Zittermann, Stefan Lucke, Jan F Gummert, Michiel Morshuis","doi":"10.1177/03913988231220268","DOIUrl":null,"url":null,"abstract":"<p><p>We conducted a prospective, open-labeled, clinical trial, with a two-by-two factorial design, of argon cold plasma application and two different types of driveline positioning for the prevention of driveline infection (DLI) in 80 patients with a left ventricular assist device (LVAD) implant. Here, we present the results of intracorporeal loop positioning (<i>n</i> = 40) versus no intracorporeal loop positioning (<i>n</i> = 40). Patients were followed up for 1 year. According to the Driveline Expert STagINg and carE grading (DESTINE) system, a DLI was considered in case of a stage 2 or higher graded infection. During follow-up, 29 (36%) patients experienced a DLI, 16 in the group with intracorporeal loop positioning and 13 in the group with no intracorporeal loop positioning. Kaplan-Meier estimates of freedom from DLI showed no statistically significant difference between study groups during follow-up (<i>p</i> = 0.33). In detail, 30-day freedom from DLI was for the groups with and without intracorporeal loop positioning 92 and 92%, respectively, and 1-year freedom from DLI was 51 and 62%, respectively. In conclusion, this controlled clinical trial was unable to show a statistically significant difference in freedom from DLI during one year of follow-up in groups with or without intracorporeal loop positioning. However, larger trials have to confirm these results.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":" ","pages":"118-121"},"PeriodicalIF":1.4000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Driveline infection according to driveline positioning in left ventricular assist device implant recipients.\",\"authors\":\"Volker Lauenroth, Armin Zittermann, Stefan Lucke, Jan F Gummert, Michiel Morshuis\",\"doi\":\"10.1177/03913988231220268\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We conducted a prospective, open-labeled, clinical trial, with a two-by-two factorial design, of argon cold plasma application and two different types of driveline positioning for the prevention of driveline infection (DLI) in 80 patients with a left ventricular assist device (LVAD) implant. Here, we present the results of intracorporeal loop positioning (<i>n</i> = 40) versus no intracorporeal loop positioning (<i>n</i> = 40). Patients were followed up for 1 year. According to the Driveline Expert STagINg and carE grading (DESTINE) system, a DLI was considered in case of a stage 2 or higher graded infection. During follow-up, 29 (36%) patients experienced a DLI, 16 in the group with intracorporeal loop positioning and 13 in the group with no intracorporeal loop positioning. Kaplan-Meier estimates of freedom from DLI showed no statistically significant difference between study groups during follow-up (<i>p</i> = 0.33). In detail, 30-day freedom from DLI was for the groups with and without intracorporeal loop positioning 92 and 92%, respectively, and 1-year freedom from DLI was 51 and 62%, respectively. In conclusion, this controlled clinical trial was unable to show a statistically significant difference in freedom from DLI during one year of follow-up in groups with or without intracorporeal loop positioning. However, larger trials have to confirm these results.</p>\",\"PeriodicalId\":13932,\"journal\":{\"name\":\"International Journal of Artificial Organs\",\"volume\":\" \",\"pages\":\"118-121\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/03913988231220268\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988231220268","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/5 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Driveline infection according to driveline positioning in left ventricular assist device implant recipients.
We conducted a prospective, open-labeled, clinical trial, with a two-by-two factorial design, of argon cold plasma application and two different types of driveline positioning for the prevention of driveline infection (DLI) in 80 patients with a left ventricular assist device (LVAD) implant. Here, we present the results of intracorporeal loop positioning (n = 40) versus no intracorporeal loop positioning (n = 40). Patients were followed up for 1 year. According to the Driveline Expert STagINg and carE grading (DESTINE) system, a DLI was considered in case of a stage 2 or higher graded infection. During follow-up, 29 (36%) patients experienced a DLI, 16 in the group with intracorporeal loop positioning and 13 in the group with no intracorporeal loop positioning. Kaplan-Meier estimates of freedom from DLI showed no statistically significant difference between study groups during follow-up (p = 0.33). In detail, 30-day freedom from DLI was for the groups with and without intracorporeal loop positioning 92 and 92%, respectively, and 1-year freedom from DLI was 51 and 62%, respectively. In conclusion, this controlled clinical trial was unable to show a statistically significant difference in freedom from DLI during one year of follow-up in groups with or without intracorporeal loop positioning. However, larger trials have to confirm these results.
期刊介绍:
The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.