{"title":"评估预着色和人工着色整体氧化锆的着色再现性和机械性能。","authors":"I A Albakri, Z AlHorani, M Hatamleh, W M Al-Omari","doi":"10.2341/23-016-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to investigate the effect of manual coloring of blank monolithic zirconia blocks of four materials on their shade reproducibility, flexural strength, and surface roughness as compared with preshaded blocks of the same material.</p><p><strong>Methods and materials: </strong>Eight disc-shaped specimens (diameter=12mm; height=2mm) and eight bar-shaped specimens (25×2×2 mm) were milled from the shaded and non-shaded blocks of the four zirconia systems: Ceramill, Kerox, White Peaks, and Dental Direkt. In total, 128 specimens were fabricated. The non-shaded specimens of each system were coloured according to A2 shade. The surface roughness (Ra) was measured using a contact profilometer. Color difference was calculated according to the CIEDE2000 formula. The bar-shaped specimens were loaded to fracture following three-point bend testing at 1 mm/minute crosshead speed. Data were analysed following one-way analysis of variance (ANOVA), and the Tukey post-hoc test (p=0.05).</p><p><strong>Results: </strong>Manual-coloring affected the surface roughness, color difference, and flexural strength of three materials in comparison to their preshaded blocks (p<0.05). White Peaks was not affected (p>0.05). Ra values ranged from 1.1-1.9; three materials were not affected (p>0.05). Kerox preshaded blocks were the smoothest (p<0.05) but became the roughest once colored (p<0.05). White Peaks and Dental Direkt materials had preshaded blocks matching the A2 guide-tab (p>0.05). DE was perceptible and unacceptable for the preshaded and manually shaded blocks of all materials tested (ΔE>1.8). While manual coloring reduced flexural strength of Ceramill and Dental Direkt (p<0.05), flexural strength was retained by Kerox and White Peaks (p>0.05).</p><p><strong>Conclusions: </strong>White Peaks was not affected by the coloring technique. Coloring had negative effects on Ceramill flexural strength and color reproducibility.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":"49 1","pages":"110-116"},"PeriodicalIF":1.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Shade Reproducibility and Mechanical Properties of Preshaded and Manually Shaded Monolithic Zirconia.\",\"authors\":\"I A Albakri, Z AlHorani, M Hatamleh, W M Al-Omari\",\"doi\":\"10.2341/23-016-L\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This study aimed to investigate the effect of manual coloring of blank monolithic zirconia blocks of four materials on their shade reproducibility, flexural strength, and surface roughness as compared with preshaded blocks of the same material.</p><p><strong>Methods and materials: </strong>Eight disc-shaped specimens (diameter=12mm; height=2mm) and eight bar-shaped specimens (25×2×2 mm) were milled from the shaded and non-shaded blocks of the four zirconia systems: Ceramill, Kerox, White Peaks, and Dental Direkt. In total, 128 specimens were fabricated. The non-shaded specimens of each system were coloured according to A2 shade. The surface roughness (Ra) was measured using a contact profilometer. Color difference was calculated according to the CIEDE2000 formula. The bar-shaped specimens were loaded to fracture following three-point bend testing at 1 mm/minute crosshead speed. Data were analysed following one-way analysis of variance (ANOVA), and the Tukey post-hoc test (p=0.05).</p><p><strong>Results: </strong>Manual-coloring affected the surface roughness, color difference, and flexural strength of three materials in comparison to their preshaded blocks (p<0.05). White Peaks was not affected (p>0.05). Ra values ranged from 1.1-1.9; three materials were not affected (p>0.05). Kerox preshaded blocks were the smoothest (p<0.05) but became the roughest once colored (p<0.05). White Peaks and Dental Direkt materials had preshaded blocks matching the A2 guide-tab (p>0.05). DE was perceptible and unacceptable for the preshaded and manually shaded blocks of all materials tested (ΔE>1.8). While manual coloring reduced flexural strength of Ceramill and Dental Direkt (p<0.05), flexural strength was retained by Kerox and White Peaks (p>0.05).</p><p><strong>Conclusions: </strong>White Peaks was not affected by the coloring technique. Coloring had negative effects on Ceramill flexural strength and color reproducibility.</p>\",\"PeriodicalId\":19502,\"journal\":{\"name\":\"Operative dentistry\",\"volume\":\"49 1\",\"pages\":\"110-116\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Operative dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2341/23-016-L\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/23-016-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
研究目的本研究旨在探讨与预先着色的同种材料氧化锆块相比,人工着色四种材料的空白整体氧化锆块对其色泽再现性、抗弯强度和表面粗糙度的影响:从四种氧化锆系统的着色块和非着色块上磨制出八个圆盘形试样(直径=12 毫米;高=2 毫米)和八个条形试样(25×2×2 毫米):Ceramill、Kerox、White Peaks 和 Dental Direkt。总共制作了 128 个试样。每个系统的非阴影试样都根据 A2 阴影着色。使用接触式轮廓仪测量表面粗糙度(Ra)。色差根据 CIEDE2000 公式计算。条形试样以 1 毫米/分钟的十字头速度进行三点弯曲测试,加载至断裂。数据分析采用单因素方差分析(ANOVA)和Tukey事后检验(P=0.05):与预着色块相比,人工着色影响了三种材料的表面粗糙度、色差和抗折强度(p0.05)。Ra 值范围为 1.1-1.9;三种材料不受影响(p>0.05)。Kerox 预着色砌块最光滑(p0.05)。在所有测试材料中,预着色和人工着色砌块的 DE 都是可感知和不可接受的(ΔE>1.8)。人工着色降低了 Ceramill 和 Dental Direkt 的抗折强度(p0.05):白色峰值不受着色技术的影响。着色对 Ceramill 抗折强度和颜色再现性有负面影响。
Evaluation of Shade Reproducibility and Mechanical Properties of Preshaded and Manually Shaded Monolithic Zirconia.
Objectives: This study aimed to investigate the effect of manual coloring of blank monolithic zirconia blocks of four materials on their shade reproducibility, flexural strength, and surface roughness as compared with preshaded blocks of the same material.
Methods and materials: Eight disc-shaped specimens (diameter=12mm; height=2mm) and eight bar-shaped specimens (25×2×2 mm) were milled from the shaded and non-shaded blocks of the four zirconia systems: Ceramill, Kerox, White Peaks, and Dental Direkt. In total, 128 specimens were fabricated. The non-shaded specimens of each system were coloured according to A2 shade. The surface roughness (Ra) was measured using a contact profilometer. Color difference was calculated according to the CIEDE2000 formula. The bar-shaped specimens were loaded to fracture following three-point bend testing at 1 mm/minute crosshead speed. Data were analysed following one-way analysis of variance (ANOVA), and the Tukey post-hoc test (p=0.05).
Results: Manual-coloring affected the surface roughness, color difference, and flexural strength of three materials in comparison to their preshaded blocks (p<0.05). White Peaks was not affected (p>0.05). Ra values ranged from 1.1-1.9; three materials were not affected (p>0.05). Kerox preshaded blocks were the smoothest (p<0.05) but became the roughest once colored (p<0.05). White Peaks and Dental Direkt materials had preshaded blocks matching the A2 guide-tab (p>0.05). DE was perceptible and unacceptable for the preshaded and manually shaded blocks of all materials tested (ΔE>1.8). While manual coloring reduced flexural strength of Ceramill and Dental Direkt (p<0.05), flexural strength was retained by Kerox and White Peaks (p>0.05).
Conclusions: White Peaks was not affected by the coloring technique. Coloring had negative effects on Ceramill flexural strength and color reproducibility.
期刊介绍:
Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts.
One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use.
The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity