Lucy Hearn, Rachael Szafnauer, Rebecca Cole, Bob Green, Jan Peter Mayser, Vikas Tomar, Kaushik Banerjee, Priyesh Amin
{"title":"利用气相色谱-质谱联用技术对食品中残留的熏蒸剂环氧乙烷和 2-氯乙醇进行自动无低温顶空阱分析。","authors":"Lucy Hearn, Rachael Szafnauer, Rebecca Cole, Bob Green, Jan Peter Mayser, Vikas Tomar, Kaushik Banerjee, Priyesh Amin","doi":"10.1080/03601234.2023.2298169","DOIUrl":null,"url":null,"abstract":"<p><p>Ethylene oxide (EtO), although banned for use, is still being detected in foodstuffs that have been fumigated to eradicate pests during storage and transport. Residual levels over the European Union's (EU) maximum residue limit (MRL) pose severe health concerns. Recent detection of EtO and its by-product 2-chloroethanol (2-CE) at alarming levels have led to product recalls throughout the EU. Here, a simple, automated headspace (HS)-trap method for the simultaneous determination of EtO and its derivative 2-CE by gas chromatography-mass spectrometry (GC-MS) at the required MRL of ≤ 0.05 mg/kg has been implemented. Syringe-based HS combined with backflushed trapping technology provided enrichment of multiple extractions from the same sample vial (known as multi-step enrichment or MSE®) to increase sensitivity for EtO and 2-CE analysis by GC-MS using single-ion-monitoring (SIM) mode. Method detection limits (MDLs) of 0.00059 mg/kg and 0.00219 mg/kg for EtO and 2-CE, respectively, were obtained without the need for manual handling, solvent extraction or derivatization methods. Recoveries were shown to average (<i>n</i> = 5) at 98% and 107% for EtO and 2-CE, respectively, and the reproducibility was <10% for both compounds.</p>","PeriodicalId":15720,"journal":{"name":"Journal of Environmental Science and Health Part B-pesticides Food Contaminants and Agricultural Wastes","volume":" ","pages":"81-87"},"PeriodicalIF":1.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Automated, cryogen-free headspace-trap with gas chromatography-mass spectrometry analysis of ethylene oxide and 2-chloroethanol as residual fumigants in foods.\",\"authors\":\"Lucy Hearn, Rachael Szafnauer, Rebecca Cole, Bob Green, Jan Peter Mayser, Vikas Tomar, Kaushik Banerjee, Priyesh Amin\",\"doi\":\"10.1080/03601234.2023.2298169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ethylene oxide (EtO), although banned for use, is still being detected in foodstuffs that have been fumigated to eradicate pests during storage and transport. Residual levels over the European Union's (EU) maximum residue limit (MRL) pose severe health concerns. Recent detection of EtO and its by-product 2-chloroethanol (2-CE) at alarming levels have led to product recalls throughout the EU. Here, a simple, automated headspace (HS)-trap method for the simultaneous determination of EtO and its derivative 2-CE by gas chromatography-mass spectrometry (GC-MS) at the required MRL of ≤ 0.05 mg/kg has been implemented. Syringe-based HS combined with backflushed trapping technology provided enrichment of multiple extractions from the same sample vial (known as multi-step enrichment or MSE®) to increase sensitivity for EtO and 2-CE analysis by GC-MS using single-ion-monitoring (SIM) mode. Method detection limits (MDLs) of 0.00059 mg/kg and 0.00219 mg/kg for EtO and 2-CE, respectively, were obtained without the need for manual handling, solvent extraction or derivatization methods. Recoveries were shown to average (<i>n</i> = 5) at 98% and 107% for EtO and 2-CE, respectively, and the reproducibility was <10% for both compounds.</p>\",\"PeriodicalId\":15720,\"journal\":{\"name\":\"Journal of Environmental Science and Health Part B-pesticides Food Contaminants and Agricultural Wastes\",\"volume\":\" \",\"pages\":\"81-87\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Environmental Science and Health Part B-pesticides Food Contaminants and Agricultural Wastes\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1080/03601234.2023.2298169\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Environmental Science and Health Part B-pesticides Food Contaminants and Agricultural Wastes","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1080/03601234.2023.2298169","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/5 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Automated, cryogen-free headspace-trap with gas chromatography-mass spectrometry analysis of ethylene oxide and 2-chloroethanol as residual fumigants in foods.
Ethylene oxide (EtO), although banned for use, is still being detected in foodstuffs that have been fumigated to eradicate pests during storage and transport. Residual levels over the European Union's (EU) maximum residue limit (MRL) pose severe health concerns. Recent detection of EtO and its by-product 2-chloroethanol (2-CE) at alarming levels have led to product recalls throughout the EU. Here, a simple, automated headspace (HS)-trap method for the simultaneous determination of EtO and its derivative 2-CE by gas chromatography-mass spectrometry (GC-MS) at the required MRL of ≤ 0.05 mg/kg has been implemented. Syringe-based HS combined with backflushed trapping technology provided enrichment of multiple extractions from the same sample vial (known as multi-step enrichment or MSE®) to increase sensitivity for EtO and 2-CE analysis by GC-MS using single-ion-monitoring (SIM) mode. Method detection limits (MDLs) of 0.00059 mg/kg and 0.00219 mg/kg for EtO and 2-CE, respectively, were obtained without the need for manual handling, solvent extraction or derivatization methods. Recoveries were shown to average (n = 5) at 98% and 107% for EtO and 2-CE, respectively, and the reproducibility was <10% for both compounds.