{"title":"机器人辅助寰枢椎手术中 Magerl 螺钉置入的准确性和风险因素:病例系列研究","authors":"Wu Jiayuan,&nbsp;Wei Yi,&nbsp;Duan Fangfang,&nbsp;He Da,&nbsp;Jiang Xieyuan,&nbsp;Tian Wei","doi":"10.1002/rcs.2603","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>To assess the accuracy of robot-assisted Magerl screw placement and explore the factors affecting the accuracy.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A retrospective analysis of patients who underwent robot-assisted Magerl screw placement was performed. The accuracy of Magerl screw placement was evaluated according to the Gertzbein and Robbins scale.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>47 Magerl screws were placed in 24 consecutive patients. 32 Magerl screws were narrower than the C2 isthmus height and 26 of them were grade A. 15 Magerl screws were wider than the C2 isthmus height and all of them were grade B. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter were associated with a higher probability of cortical breach.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The accuracy of robot-assisted Magerl screw placement was excellent. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter increased the risk of cortical breach.</p>\n </section>\n </div>","PeriodicalId":50311,"journal":{"name":"International Journal of Medical Robotics and Computer Assisted Surgery","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy and risk factors of Magerl screw placement in robot-assisted atlantoaxial surgery: A case series study\",\"authors\":\"Wu Jiayuan,&nbsp;Wei Yi,&nbsp;Duan Fangfang,&nbsp;He Da,&nbsp;Jiang Xieyuan,&nbsp;Tian Wei\",\"doi\":\"10.1002/rcs.2603\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>To assess the accuracy of robot-assisted Magerl screw placement and explore the factors affecting the accuracy.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>A retrospective analysis of patients who underwent robot-assisted Magerl screw placement was performed. The accuracy of Magerl screw placement was evaluated according to the Gertzbein and Robbins scale.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>47 Magerl screws were placed in 24 consecutive patients. 32 Magerl screws were narrower than the C2 isthmus height and 26 of them were grade A. 15 Magerl screws were wider than the C2 isthmus height and all of them were grade B. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter were associated with a higher probability of cortical breach.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>The accuracy of robot-assisted Magerl screw placement was excellent. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter increased the risk of cortical breach.</p>\\n </section>\\n </div>\",\"PeriodicalId\":50311,\"journal\":{\"name\":\"International Journal of Medical Robotics and Computer Assisted Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-12-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Medical Robotics and Computer Assisted Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/rcs.2603\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Robotics and Computer Assisted Surgery","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcs.2603","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

评估机器人辅助 Magerl 螺钉置入的准确性,并探讨影响准确性的因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy and risk factors of Magerl screw placement in robot-assisted atlantoaxial surgery: A case series study

Background

To assess the accuracy of robot-assisted Magerl screw placement and explore the factors affecting the accuracy.

Methods

A retrospective analysis of patients who underwent robot-assisted Magerl screw placement was performed. The accuracy of Magerl screw placement was evaluated according to the Gertzbein and Robbins scale.

Results

47 Magerl screws were placed in 24 consecutive patients. 32 Magerl screws were narrower than the C2 isthmus height and 26 of them were grade A. 15 Magerl screws were wider than the C2 isthmus height and all of them were grade B. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter were associated with a higher probability of cortical breach.

Conclusion

The accuracy of robot-assisted Magerl screw placement was excellent. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter increased the risk of cortical breach.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
12.00%
发文量
131
审稿时长
6-12 weeks
期刊介绍: The International Journal of Medical Robotics and Computer Assisted Surgery provides a cross-disciplinary platform for presenting the latest developments in robotics and computer assisted technologies for medical applications. The journal publishes cutting-edge papers and expert reviews, complemented by commentaries, correspondence and conference highlights that stimulate discussion and exchange of ideas. Areas of interest include robotic surgery aids and systems, operative planning tools, medical imaging and visualisation, simulation and navigation, virtual reality, intuitive command and control systems, haptics and sensor technologies. In addition to research and surgical planning studies, the journal welcomes papers detailing clinical trials and applications of computer-assisted workflows and robotic systems in neurosurgery, urology, paediatric, orthopaedic, craniofacial, cardiovascular, thoraco-abdominal, musculoskeletal and visceral surgery. Articles providing critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies, commenting on ease of use, or addressing surgical education and training issues are also encouraged. The journal aims to foster a community that encompasses medical practitioners, researchers, and engineers and computer scientists developing robotic systems and computational tools in academic and commercial environments, with the intention of promoting and developing these exciting areas of medical technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信