{"title":"胸主动脉支架移植物机械性能测试设备的设计与实施。","authors":"Shiju Yan, Chengli Song, Yuqing Yang, Jilei Xu, Yanjie Chen, Yu Zhou","doi":"10.1080/13645706.2023.2295951","DOIUrl":null,"url":null,"abstract":"<p><p>The mechanical properties of the stent graft are important factors influencing the outcome of TEVAR treatment and the occurrence of postoperative complications. The aim of this study is to improve and design a mechanical performance testing equipment for thoracic aortic stent grafts. The mechanical performance testing equipment consists of a radial force testing equipment of the stent graft designed by the wire compression grip method and a dynamic straightening force testing device with stable and controllable test conditions and continuously variable test angles. By constructing the testing equipment to physically measure the stent specimen, the experimental results reflect the trend of change and the simulation results are basically consistent, i.e. the mechanical properties of the thoracic aortic stent designed in this study is feasible and the measured data are valid. The testing equipment can provide the basis and reference direction for the quality testing of stent graft products, optimisation of mechanical properties of stent grafts and R&D innovation.</p>","PeriodicalId":18537,"journal":{"name":"Minimally Invasive Therapy & Allied Technologies","volume":" ","pages":"120-128"},"PeriodicalIF":1.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and implementation of mechanical property testing equipment for thoracic aortic stent grafts.\",\"authors\":\"Shiju Yan, Chengli Song, Yuqing Yang, Jilei Xu, Yanjie Chen, Yu Zhou\",\"doi\":\"10.1080/13645706.2023.2295951\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The mechanical properties of the stent graft are important factors influencing the outcome of TEVAR treatment and the occurrence of postoperative complications. The aim of this study is to improve and design a mechanical performance testing equipment for thoracic aortic stent grafts. The mechanical performance testing equipment consists of a radial force testing equipment of the stent graft designed by the wire compression grip method and a dynamic straightening force testing device with stable and controllable test conditions and continuously variable test angles. By constructing the testing equipment to physically measure the stent specimen, the experimental results reflect the trend of change and the simulation results are basically consistent, i.e. the mechanical properties of the thoracic aortic stent designed in this study is feasible and the measured data are valid. The testing equipment can provide the basis and reference direction for the quality testing of stent graft products, optimisation of mechanical properties of stent grafts and R&D innovation.</p>\",\"PeriodicalId\":18537,\"journal\":{\"name\":\"Minimally Invasive Therapy & Allied Technologies\",\"volume\":\" \",\"pages\":\"120-128\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Minimally Invasive Therapy & Allied Technologies\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/13645706.2023.2295951\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minimally Invasive Therapy & Allied Technologies","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/13645706.2023.2295951","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
Design and implementation of mechanical property testing equipment for thoracic aortic stent grafts.
The mechanical properties of the stent graft are important factors influencing the outcome of TEVAR treatment and the occurrence of postoperative complications. The aim of this study is to improve and design a mechanical performance testing equipment for thoracic aortic stent grafts. The mechanical performance testing equipment consists of a radial force testing equipment of the stent graft designed by the wire compression grip method and a dynamic straightening force testing device with stable and controllable test conditions and continuously variable test angles. By constructing the testing equipment to physically measure the stent specimen, the experimental results reflect the trend of change and the simulation results are basically consistent, i.e. the mechanical properties of the thoracic aortic stent designed in this study is feasible and the measured data are valid. The testing equipment can provide the basis and reference direction for the quality testing of stent graft products, optimisation of mechanical properties of stent grafts and R&D innovation.
期刊介绍:
Minimally Invasive Therapy and Allied Technologies (MITAT) is an international forum for endoscopic surgeons, interventional radiologists and industrial instrument manufacturers. It is the official journal of the Society for Medical Innovation and Technology (SMIT) whose membership includes representatives from a broad spectrum of medical specialities, instrument manufacturing and research. The journal brings the latest developments and innovations in minimally invasive therapy to its readers. What makes Minimally Invasive Therapy and Allied Technologies unique is that we publish one or two special issues each year, which are devoted to a specific theme. Key topics covered by the journal include: interventional radiology, endoscopic surgery, imaging technology, manipulators and robotics for surgery and education and training for MIS.