{"title":"对宽闪沸条件下非对称多孔直喷式汽油喷射器喷雾溃缩过程的一般理解","authors":"Jingyu Zhang, Yanfei Li, Hongming Xu, Yang Liu, Xiao Ma, Shijin Shuai","doi":"10.1177/14680874221149244","DOIUrl":null,"url":null,"abstract":"How the under-expansion impacts the flash-boiling spray collapse process over wide superheat levels ( Rp, defined as the ratio of saturation pressure to ambient pressure) is not well understood. In the present study, n-hexane flash-boiling sprays issued from a five-hole asymmetrical injector were experimentally and numerically studied to obtain a more general understanding of the spray collapse with wide Rp variation. The experimental results proved that the collapse in the transitional region occurs in the far field, unlike the fully collapse that occurred in the near-nozzle region. The numerical results demonstrated the complexity of individual jet evolutions and their interactions over wide Rp. For individual flash-boiling jets, there were different behaviors in the near-nozzle region. In the case with Rp slightly larger than 1, no shock waves can be observed, but a set of compression-expansion chains. The further increase in Rp caused the generation of shock waves, and resultantly the primary cells were established. For the multi-jet sprays, the further increase in Rp enlarged the primary cells, leading to their interactions and the generation of secondary cells. When Rp was sufficiently higher, the further interactions among primary and secondary cells could cause the generation of tertiary cell. Orderly interactions of shock cells were observed with increasing Rp, that is, the interactions initially occur between the adjacent jets with smaller distances, and then other jets were involved. Based on the results: It was found that the compression-expansion chains caused the low- Rp flash-boiling spray collapse in the far field; With the increase in Rp, the shock waves and shock-to-shock interaction become the main contributor to spray collapse, leading collapse appearing in the near-nozzle region.","PeriodicalId":14034,"journal":{"name":"International Journal of Engine Research","volume":"15 3","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2023-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"General understanding on spray collapse process of an asymmetrical multi-hole direct injection gasoline injector under wide flash-boiling conditions\",\"authors\":\"Jingyu Zhang, Yanfei Li, Hongming Xu, Yang Liu, Xiao Ma, Shijin Shuai\",\"doi\":\"10.1177/14680874221149244\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"How the under-expansion impacts the flash-boiling spray collapse process over wide superheat levels ( Rp, defined as the ratio of saturation pressure to ambient pressure) is not well understood. In the present study, n-hexane flash-boiling sprays issued from a five-hole asymmetrical injector were experimentally and numerically studied to obtain a more general understanding of the spray collapse with wide Rp variation. The experimental results proved that the collapse in the transitional region occurs in the far field, unlike the fully collapse that occurred in the near-nozzle region. The numerical results demonstrated the complexity of individual jet evolutions and their interactions over wide Rp. For individual flash-boiling jets, there were different behaviors in the near-nozzle region. In the case with Rp slightly larger than 1, no shock waves can be observed, but a set of compression-expansion chains. The further increase in Rp caused the generation of shock waves, and resultantly the primary cells were established. For the multi-jet sprays, the further increase in Rp enlarged the primary cells, leading to their interactions and the generation of secondary cells. When Rp was sufficiently higher, the further interactions among primary and secondary cells could cause the generation of tertiary cell. Orderly interactions of shock cells were observed with increasing Rp, that is, the interactions initially occur between the adjacent jets with smaller distances, and then other jets were involved. Based on the results: It was found that the compression-expansion chains caused the low- Rp flash-boiling spray collapse in the far field; With the increase in Rp, the shock waves and shock-to-shock interaction become the main contributor to spray collapse, leading collapse appearing in the near-nozzle region.\",\"PeriodicalId\":14034,\"journal\":{\"name\":\"International Journal of Engine Research\",\"volume\":\"15 3\",\"pages\":\"\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2023-12-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Engine Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/14680874221149244\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Engine Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/14680874221149244","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0
摘要
人们对膨胀不足如何影响宽过热水平(Rp,定义为饱和压力与环境压力之比)下的闪沸喷雾塌陷过程还不甚了解。在本研究中,对从五孔非对称喷射器喷出的正己烷闪沸喷雾进行了实验和数值研究,以便对 Rp 变化较大时的喷雾塌陷有更全面的了解。实验结果证明,与发生在近喷嘴区域的完全塌陷不同,过渡区域的塌陷发生在远场。数值结果表明了在宽 Rp 条件下单个喷流演变及其相互作用的复杂性。对于单个闪沸射流,在近喷嘴区域有不同的行为。在 Rp 略大于 1 的情况下,没有观察到冲击波,但有一组压缩-膨胀链。Rp 进一步增大会产生冲击波,从而形成原电池。对于多喷嘴喷雾,Rp 的进一步增加扩大了原生细胞,导致它们之间的相互作用,并产生了次生细胞。当 Rp 足够高时,原生细胞和次生细胞之间的进一步相互作用会导致三级细胞的产生。随着 Rp 的增大,冲击细胞的有序相互作用被观察到,即相互作用最初发生在距离较小的相邻射流之间,然后其他射流也参与进来。根据这些结果:研究发现,压缩-膨胀链导致了低 Rp 闪沸喷雾在远场的坍塌;随着 Rp 的增大,冲击波和冲击-冲击相互作用成为喷雾坍塌的主要因素,导致坍塌出现在近喷嘴区域。
General understanding on spray collapse process of an asymmetrical multi-hole direct injection gasoline injector under wide flash-boiling conditions
How the under-expansion impacts the flash-boiling spray collapse process over wide superheat levels ( Rp, defined as the ratio of saturation pressure to ambient pressure) is not well understood. In the present study, n-hexane flash-boiling sprays issued from a five-hole asymmetrical injector were experimentally and numerically studied to obtain a more general understanding of the spray collapse with wide Rp variation. The experimental results proved that the collapse in the transitional region occurs in the far field, unlike the fully collapse that occurred in the near-nozzle region. The numerical results demonstrated the complexity of individual jet evolutions and their interactions over wide Rp. For individual flash-boiling jets, there were different behaviors in the near-nozzle region. In the case with Rp slightly larger than 1, no shock waves can be observed, but a set of compression-expansion chains. The further increase in Rp caused the generation of shock waves, and resultantly the primary cells were established. For the multi-jet sprays, the further increase in Rp enlarged the primary cells, leading to their interactions and the generation of secondary cells. When Rp was sufficiently higher, the further interactions among primary and secondary cells could cause the generation of tertiary cell. Orderly interactions of shock cells were observed with increasing Rp, that is, the interactions initially occur between the adjacent jets with smaller distances, and then other jets were involved. Based on the results: It was found that the compression-expansion chains caused the low- Rp flash-boiling spray collapse in the far field; With the increase in Rp, the shock waves and shock-to-shock interaction become the main contributor to spray collapse, leading collapse appearing in the near-nozzle region.