使用比色环介导等温扩增检测法评估扩增 DNA 的测量精度。

IF 2.2 4区 工程技术 Q3 BIOCHEMICAL RESEARCH METHODS
BioTechniques Pub Date : 2024-03-01 Epub Date: 2023-12-22 DOI:10.2144/btn-2023-0104
Seongsoo Hong, Jeongho Park, Jaekyung Bok, Euna Cho, Joowon Rhee
{"title":"使用比色环介导等温扩增检测法评估扩增 DNA 的测量精度。","authors":"Seongsoo Hong, Jeongho Park, Jaekyung Bok, Euna Cho, Joowon Rhee","doi":"10.2144/btn-2023-0104","DOIUrl":null,"url":null,"abstract":"<p><p>A colorimetric loop-mediated isothermal amplification assay detects changes in pH during amplification based on color changes at a constant temperature. Currently, various studies have focused on developing and assessing molecular point-of-care testing instruments. In this study, we evaluated amplified DNA concentrations measured using the colorimetric LAMP assay of the 1POT™ Professional device (1drop Inc, Korea). Results of the 1POT analysis of clinical samples were compared with measurements obtained from the Qubit™ 4 and NanoDrop™ 2000 devices (both from Thermo Fisher Scientific, MA, USA). These results showed a correlation of 0.98 (95% CI: 0.96-0.99) and 0.96 (95% CI: 0.92-0.98) between 1POT and the Qubit and NanoDrop. 1POT can measure amplified DNA accurately and is suitable for on-site molecular diagnostics.</p>","PeriodicalId":8945,"journal":{"name":"BioTechniques","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of measurement accuracy of amplified DNA using a colorimetric loop-mediated isothermal amplification assay.\",\"authors\":\"Seongsoo Hong, Jeongho Park, Jaekyung Bok, Euna Cho, Joowon Rhee\",\"doi\":\"10.2144/btn-2023-0104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A colorimetric loop-mediated isothermal amplification assay detects changes in pH during amplification based on color changes at a constant temperature. Currently, various studies have focused on developing and assessing molecular point-of-care testing instruments. In this study, we evaluated amplified DNA concentrations measured using the colorimetric LAMP assay of the 1POT™ Professional device (1drop Inc, Korea). Results of the 1POT analysis of clinical samples were compared with measurements obtained from the Qubit™ 4 and NanoDrop™ 2000 devices (both from Thermo Fisher Scientific, MA, USA). These results showed a correlation of 0.98 (95% CI: 0.96-0.99) and 0.96 (95% CI: 0.92-0.98) between 1POT and the Qubit and NanoDrop. 1POT can measure amplified DNA accurately and is suitable for on-site molecular diagnostics.</p>\",\"PeriodicalId\":8945,\"journal\":{\"name\":\"BioTechniques\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BioTechniques\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2144/btn-2023-0104\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BioTechniques","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2144/btn-2023-0104","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

比色环介导等温扩增检测法可在恒定温度下根据颜色变化检测扩增过程中的 pH 值变化。目前,各种研究都侧重于开发和评估分子护理点检测仪器。在本研究中,我们评估了使用 1POT™ 专业设备(1drop Inc,韩国)的比色 LAMP 检测法测量的扩增 DNA 浓度。临床样本的 1POT 分析结果与 Qubit™ 4 和 NanoDrop™ 2000 设备(均来自美国马萨诸塞州赛默飞世尔科技公司)的测量结果进行了比较。这些结果表明,1POT 与 Qubit 和 NanoDrop 的相关性分别为 0.98(95% CI:0.96-0.99)和 0.96(95% CI:0.92-0.98)。1POT 可精确测量扩增 DNA,适用于现场分子诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of measurement accuracy of amplified DNA using a colorimetric loop-mediated isothermal amplification assay.

A colorimetric loop-mediated isothermal amplification assay detects changes in pH during amplification based on color changes at a constant temperature. Currently, various studies have focused on developing and assessing molecular point-of-care testing instruments. In this study, we evaluated amplified DNA concentrations measured using the colorimetric LAMP assay of the 1POT™ Professional device (1drop Inc, Korea). Results of the 1POT analysis of clinical samples were compared with measurements obtained from the Qubit™ 4 and NanoDrop™ 2000 devices (both from Thermo Fisher Scientific, MA, USA). These results showed a correlation of 0.98 (95% CI: 0.96-0.99) and 0.96 (95% CI: 0.92-0.98) between 1POT and the Qubit and NanoDrop. 1POT can measure amplified DNA accurately and is suitable for on-site molecular diagnostics.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BioTechniques
BioTechniques 工程技术-生化研究方法
CiteScore
4.40
自引率
0.00%
发文量
68
审稿时长
3.3 months
期刊介绍: BioTechniques is a peer-reviewed, open-access journal dedicated to publishing original laboratory methods, related technical and software tools, and methods-oriented review articles that are of broad interest to professional life scientists, as well as to scientists from other disciplines (e.g., chemistry, physics, computer science, plant and agricultural science and climate science) interested in life science applications for their technologies. Since 1983, BioTechniques has been a leading peer-reviewed journal for methods-related research. The journal considers: Reports describing innovative new methods, platforms and software, substantive modifications to existing methods, or innovative applications of existing methods, techniques & tools to new models or scientific questions Descriptions of technical tools that facilitate the design or performance of experiments or data analysis, such as software and simple laboratory devices Surveys of technical approaches related to broad fields of research Reviews discussing advancements in techniques and methods related to broad fields of research Letters to the Editor and Expert Opinions highlighting interesting observations or cautionary tales concerning experimental design, methodology or analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信