Khashayar Ghadirinejad, Stephen Graves, Richard de Steiger, Nicole Pratt, Lucian B Solomon, Mark Taylor, Reza Hashemi
{"title":"在评估社区内初级全髋关节假体的性能时,什么是最合适的比较组?","authors":"Khashayar Ghadirinejad, Stephen Graves, Richard de Steiger, Nicole Pratt, Lucian B Solomon, Mark Taylor, Reza Hashemi","doi":"10.1177/11207000231216708","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There are variations in the performance of individual prostheses used in hip replacements. Some of which have unexpectedly higher revision rates - outliers. The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) has established a standardised multi-stage approach for identifying these devices. This is done by comparing the revision rates of individual prostheses to all other prostheses in class, with the exception of large head metal-on-metal (LHMoM) prostheses. However, improvements in device design and performance over time have required a need to reconsider the comparator group. This study aimed to identify a more specific comparator to better reflect contemporary surgical practice.</p><p><strong>Methods: </strong>The time to first revision was estimated on the data of 413,417 primary total conventional hip replacements undertaken for osteoarthritis (OA) from 01 January 2003 to 31 December 2019. Survivorship analyses with stepwise exclusions were undertaken. The first exclusion was LHMoM, followed by other non-modern bearing surfaces (defined as all the bearing couples except metal or ceramic heads on cross-linked polyethylene and mixed ceramic-on-ceramic), and then devices with modular neck-stem design or used for specific purposes (incl. constrained, dual-mobility, and head size <28 mm). Lastly, all remaining prostheses previously identified as having a higher than anticipated rate of revision (HTARR) were also excluded.</p><p><strong>Results: </strong>These exclusions progressively reduced the cumulative percent revision (CPR) rate. The final comparator, which only includes satisfactory-performed prostheses of contemporary design and use, has a 10-year CPR of 4.30% (95% CI, 4.2-4.41) which is lower than 4.93% (95% CI, 4.84-5.02) for the current comparator used by the AOANJRR (all prostheses excluding LHMOM). Over the study period, 13 additional components were identified utilising the modified comparator.</p><p><strong>Conclusions: </strong>The calculation of the comparator revision rate should be re-evaluated to include only modern prosthesis constructs to ensure that poorly performing prostheses are identified early.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11075408/pdf/","citationCount":"0","resultStr":"{\"title\":\"What is the most appropriate comparator group to use in assessing the performance of primary total hip prostheses within the community?\",\"authors\":\"Khashayar Ghadirinejad, Stephen Graves, Richard de Steiger, Nicole Pratt, Lucian B Solomon, Mark Taylor, Reza Hashemi\",\"doi\":\"10.1177/11207000231216708\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>There are variations in the performance of individual prostheses used in hip replacements. Some of which have unexpectedly higher revision rates - outliers. The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) has established a standardised multi-stage approach for identifying these devices. This is done by comparing the revision rates of individual prostheses to all other prostheses in class, with the exception of large head metal-on-metal (LHMoM) prostheses. However, improvements in device design and performance over time have required a need to reconsider the comparator group. This study aimed to identify a more specific comparator to better reflect contemporary surgical practice.</p><p><strong>Methods: </strong>The time to first revision was estimated on the data of 413,417 primary total conventional hip replacements undertaken for osteoarthritis (OA) from 01 January 2003 to 31 December 2019. Survivorship analyses with stepwise exclusions were undertaken. The first exclusion was LHMoM, followed by other non-modern bearing surfaces (defined as all the bearing couples except metal or ceramic heads on cross-linked polyethylene and mixed ceramic-on-ceramic), and then devices with modular neck-stem design or used for specific purposes (incl. constrained, dual-mobility, and head size <28 mm). Lastly, all remaining prostheses previously identified as having a higher than anticipated rate of revision (HTARR) were also excluded.</p><p><strong>Results: </strong>These exclusions progressively reduced the cumulative percent revision (CPR) rate. The final comparator, which only includes satisfactory-performed prostheses of contemporary design and use, has a 10-year CPR of 4.30% (95% CI, 4.2-4.41) which is lower than 4.93% (95% CI, 4.84-5.02) for the current comparator used by the AOANJRR (all prostheses excluding LHMOM). Over the study period, 13 additional components were identified utilising the modified comparator.</p><p><strong>Conclusions: </strong>The calculation of the comparator revision rate should be re-evaluated to include only modern prosthesis constructs to ensure that poorly performing prostheses are identified early.</p>\",\"PeriodicalId\":12911,\"journal\":{\"name\":\"HIP International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11075408/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"HIP International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11207000231216708\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000231216708","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
What is the most appropriate comparator group to use in assessing the performance of primary total hip prostheses within the community?
Background: There are variations in the performance of individual prostheses used in hip replacements. Some of which have unexpectedly higher revision rates - outliers. The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) has established a standardised multi-stage approach for identifying these devices. This is done by comparing the revision rates of individual prostheses to all other prostheses in class, with the exception of large head metal-on-metal (LHMoM) prostheses. However, improvements in device design and performance over time have required a need to reconsider the comparator group. This study aimed to identify a more specific comparator to better reflect contemporary surgical practice.
Methods: The time to first revision was estimated on the data of 413,417 primary total conventional hip replacements undertaken for osteoarthritis (OA) from 01 January 2003 to 31 December 2019. Survivorship analyses with stepwise exclusions were undertaken. The first exclusion was LHMoM, followed by other non-modern bearing surfaces (defined as all the bearing couples except metal or ceramic heads on cross-linked polyethylene and mixed ceramic-on-ceramic), and then devices with modular neck-stem design or used for specific purposes (incl. constrained, dual-mobility, and head size <28 mm). Lastly, all remaining prostheses previously identified as having a higher than anticipated rate of revision (HTARR) were also excluded.
Results: These exclusions progressively reduced the cumulative percent revision (CPR) rate. The final comparator, which only includes satisfactory-performed prostheses of contemporary design and use, has a 10-year CPR of 4.30% (95% CI, 4.2-4.41) which is lower than 4.93% (95% CI, 4.84-5.02) for the current comparator used by the AOANJRR (all prostheses excluding LHMOM). Over the study period, 13 additional components were identified utilising the modified comparator.
Conclusions: The calculation of the comparator revision rate should be re-evaluated to include only modern prosthesis constructs to ensure that poorly performing prostheses are identified early.
期刊介绍:
HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice.
The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit.
HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are:
• Biomaterials
• Biomechanics
• Conservative Hip Surgery
• Paediatrics
• Primary and Revision Hip Arthroplasty
• Traumatology