用于经腹绒毛取样的低成本、高保真模拟器。

IF 1.6 3区 医学 Q3 OBSTETRICS & GYNECOLOGY
Fetal Diagnosis and Therapy Pub Date : 2024-01-01 Epub Date: 2023-12-11 DOI:10.1159/000534485
Megan G Lord, Matthew A Esposito, Alexis C Gimovsky, Stephen R Carr, Melissa L Russo
{"title":"用于经腹绒毛取样的低成本、高保真模拟器。","authors":"Megan G Lord, Matthew A Esposito, Alexis C Gimovsky, Stephen R Carr, Melissa L Russo","doi":"10.1159/000534485","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Chorionic villus sampling (CVS) remains essential for first-trimester genetic diagnosis, yet clinical volume may be insufficient to train new clinicians in the technique. Available simulation models are expensive, require animal parts or specialized resins, and cannot be stored for repeated use.</p><p><strong>Methods: </strong>We present a model for trans-abdominal CVS (TA-CVS) which is constructed from readily available materials costing less than $10 and can be refrigerated and re-used to train maternal-fetal medicine fellows in CVS.</p><p><strong>Results: </strong>All three attending physicians performing TA-CVS at our institution described the model as an accurate visual and tactile simulation, prompting its integration into our fellowship curriculum. To date, two senior fellows have achieved competency on the simulator and begun to perform clinical CVS under supervision, one of whom is an author on this paper. Both fellows and attendings indicated that the simulator provided a valuable tool for repeated practice prior to clinical CVS. Simulators are now maintained on the unit and have been re-used for 3 months and dozens of simulated procedures each without any apparent qualitative degradation in performance.</p><p><strong>Discussion/conclusion: </strong>We describe a low-cost easily constructed, durable, high-fidelity simulator for TA-CVS.</p>","PeriodicalId":12189,"journal":{"name":"Fetal Diagnosis and Therapy","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Low-Cost, High-Fidelity Simulator for Transabdominal Chorionic Villus Sampling.\",\"authors\":\"Megan G Lord, Matthew A Esposito, Alexis C Gimovsky, Stephen R Carr, Melissa L Russo\",\"doi\":\"10.1159/000534485\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Chorionic villus sampling (CVS) remains essential for first-trimester genetic diagnosis, yet clinical volume may be insufficient to train new clinicians in the technique. Available simulation models are expensive, require animal parts or specialized resins, and cannot be stored for repeated use.</p><p><strong>Methods: </strong>We present a model for trans-abdominal CVS (TA-CVS) which is constructed from readily available materials costing less than $10 and can be refrigerated and re-used to train maternal-fetal medicine fellows in CVS.</p><p><strong>Results: </strong>All three attending physicians performing TA-CVS at our institution described the model as an accurate visual and tactile simulation, prompting its integration into our fellowship curriculum. To date, two senior fellows have achieved competency on the simulator and begun to perform clinical CVS under supervision, one of whom is an author on this paper. Both fellows and attendings indicated that the simulator provided a valuable tool for repeated practice prior to clinical CVS. Simulators are now maintained on the unit and have been re-used for 3 months and dozens of simulated procedures each without any apparent qualitative degradation in performance.</p><p><strong>Discussion/conclusion: </strong>We describe a low-cost easily constructed, durable, high-fidelity simulator for TA-CVS.</p>\",\"PeriodicalId\":12189,\"journal\":{\"name\":\"Fetal Diagnosis and Therapy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fetal Diagnosis and Therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000534485\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fetal Diagnosis and Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000534485","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

导言:绒毛取样(CVS)仍是第一孕期遗传诊断的关键,但临床量可能不足以培训新的临床医生掌握该技术。现有的模拟模型价格昂贵,需要动物器官或专用树脂,而且无法储存以备重复使用:方法:我们介绍了一种经腹 CVS(TA-CVS)模型,该模型由现成材料制成,成本不到 10 美元,可冷藏并重复使用,用于培训母体胎儿医学(MFM)研究员进行 CVS 培训:结果:在我院进行 TA-CVS 操作的三位主治医师都认为该模型是一种准确的视觉和触觉模拟,因此将其纳入了我们的研究课程。迄今为止,已有两名高级研究员掌握了模拟器的操作技能,并开始在指导下进行临床 CVS 操作,其中一人还是本文的作者。研究员和主治医师都表示,模拟器为临床 CVS 前的反复练习提供了宝贵的工具。目前,模拟器已在该科室得到维护,并已重复使用了三个月,每台模拟器都进行了数十次模拟操作,其性能没有任何明显的下降:我们介绍了一种用于 TA-CVS 的低成本、易构建、耐用、高保真模拟器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Low-Cost, High-Fidelity Simulator for Transabdominal Chorionic Villus Sampling.

Introduction: Chorionic villus sampling (CVS) remains essential for first-trimester genetic diagnosis, yet clinical volume may be insufficient to train new clinicians in the technique. Available simulation models are expensive, require animal parts or specialized resins, and cannot be stored for repeated use.

Methods: We present a model for trans-abdominal CVS (TA-CVS) which is constructed from readily available materials costing less than $10 and can be refrigerated and re-used to train maternal-fetal medicine fellows in CVS.

Results: All three attending physicians performing TA-CVS at our institution described the model as an accurate visual and tactile simulation, prompting its integration into our fellowship curriculum. To date, two senior fellows have achieved competency on the simulator and begun to perform clinical CVS under supervision, one of whom is an author on this paper. Both fellows and attendings indicated that the simulator provided a valuable tool for repeated practice prior to clinical CVS. Simulators are now maintained on the unit and have been re-used for 3 months and dozens of simulated procedures each without any apparent qualitative degradation in performance.

Discussion/conclusion: We describe a low-cost easily constructed, durable, high-fidelity simulator for TA-CVS.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Fetal Diagnosis and Therapy
Fetal Diagnosis and Therapy 医学-妇产科学
CiteScore
4.70
自引率
9.10%
发文量
48
审稿时长
6-12 weeks
期刊介绍: The first journal to focus on the fetus as a patient, ''Fetal Diagnosis and Therapy'' provides a wide range of biomedical specialists with a single source of reports encompassing the common discipline of fetal medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信