偏振成像系统中偏振器光轴的精确校准

IF 1.1 4区 物理与天体物理 Q4 OPTICS
Bowen Lian, Naiting Gu, Yawei Xiao, Ao Tang, Linhai Huang, Changhui Rao
{"title":"偏振成像系统中偏振器光轴的精确校准","authors":"Bowen Lian, Naiting Gu, Yawei Xiao, Ao Tang, Linhai Huang, Changhui Rao","doi":"10.1007/s10043-023-00851-7","DOIUrl":null,"url":null,"abstract":"<p>Division of time polarimeter (DoTP) is one of the popular imaging instruments in several applications because of its simple configuration and accurate performance. However, calibration of the optical axis of the used polarizer is also the premise of an accurate polarimeter. In this paper, a novel on-line and accurate method is proposed to calibrate the transmission angle of the polarizer using a Wollaston prism. The Wollaston prism splits the incident light into two light beams with orthogonal polarization directions, which are vertical and parallel with the beams plane, respectively. Then these two beams pass through the candidate polarizer. The detected light intensity can be adjusted by rotating the polarizer, whose position is marked by a digital encoder. The angle of optical axis of the polarizer relative to the line of points of two light beams can be solved by a series of light intensities. Finally, the optical axis of the polarizer is calibrated on-line, and the state of polarization of incident light can be measured accurately. Numerical simulation and experiments have validated the feasibility of the proposed on-line calibration method. The experimental results show that the calibration accuracy is about 0.0106° with a maximum polarization measurement error of 3.7 × 10<sup>–4</sup>. In general, the proposed calibration method is very fast, on-line, accurate, and would be a good reference for polarization imaging and polarization calibration.</p>","PeriodicalId":722,"journal":{"name":"Optical Review","volume":"23 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accurate calibration on optical axis of polarizer in a polarization imaging system\",\"authors\":\"Bowen Lian, Naiting Gu, Yawei Xiao, Ao Tang, Linhai Huang, Changhui Rao\",\"doi\":\"10.1007/s10043-023-00851-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Division of time polarimeter (DoTP) is one of the popular imaging instruments in several applications because of its simple configuration and accurate performance. However, calibration of the optical axis of the used polarizer is also the premise of an accurate polarimeter. In this paper, a novel on-line and accurate method is proposed to calibrate the transmission angle of the polarizer using a Wollaston prism. The Wollaston prism splits the incident light into two light beams with orthogonal polarization directions, which are vertical and parallel with the beams plane, respectively. Then these two beams pass through the candidate polarizer. The detected light intensity can be adjusted by rotating the polarizer, whose position is marked by a digital encoder. The angle of optical axis of the polarizer relative to the line of points of two light beams can be solved by a series of light intensities. Finally, the optical axis of the polarizer is calibrated on-line, and the state of polarization of incident light can be measured accurately. Numerical simulation and experiments have validated the feasibility of the proposed on-line calibration method. The experimental results show that the calibration accuracy is about 0.0106° with a maximum polarization measurement error of 3.7 × 10<sup>–4</sup>. In general, the proposed calibration method is very fast, on-line, accurate, and would be a good reference for polarization imaging and polarization calibration.</p>\",\"PeriodicalId\":722,\"journal\":{\"name\":\"Optical Review\",\"volume\":\"23 1\",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optical Review\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1007/s10043-023-00851-7\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optical Review","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1007/s10043-023-00851-7","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

摘要

分时偏振仪(DoTP)以其结构简单、性能准确等优点,成为众多应用领域中比较流行的成像仪器之一。然而,校准所用偏振器的光轴也是精确偏振计的前提。本文提出了一种利用沃拉斯顿棱镜在线精确校准偏光镜透射角的新方法。沃拉斯顿棱镜将入射光分成两个偏振方向正交的光束,分别与光束平面垂直平行。然后这两束光通过候选偏振器。检测到的光强可以通过旋转偏振片来调节,偏振片的位置由数字编码器标记。偏振器的光轴相对于两束光的点线的角度可以用一系列光强来求解。最后,对偏振器的光轴进行在线标定,可以准确测量入射光的偏振状态。数值模拟和实验验证了该方法的可行性。实验结果表明,标定精度约为0.0106°,最大偏振测量误差为3.7 × 10-4。该方法具有快速、在线、准确等特点,可为偏振成像和偏振定标提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Accurate calibration on optical axis of polarizer in a polarization imaging system

Accurate calibration on optical axis of polarizer in a polarization imaging system

Division of time polarimeter (DoTP) is one of the popular imaging instruments in several applications because of its simple configuration and accurate performance. However, calibration of the optical axis of the used polarizer is also the premise of an accurate polarimeter. In this paper, a novel on-line and accurate method is proposed to calibrate the transmission angle of the polarizer using a Wollaston prism. The Wollaston prism splits the incident light into two light beams with orthogonal polarization directions, which are vertical and parallel with the beams plane, respectively. Then these two beams pass through the candidate polarizer. The detected light intensity can be adjusted by rotating the polarizer, whose position is marked by a digital encoder. The angle of optical axis of the polarizer relative to the line of points of two light beams can be solved by a series of light intensities. Finally, the optical axis of the polarizer is calibrated on-line, and the state of polarization of incident light can be measured accurately. Numerical simulation and experiments have validated the feasibility of the proposed on-line calibration method. The experimental results show that the calibration accuracy is about 0.0106° with a maximum polarization measurement error of 3.7 × 10–4. In general, the proposed calibration method is very fast, on-line, accurate, and would be a good reference for polarization imaging and polarization calibration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Optical Review
Optical Review 物理-光学
CiteScore
2.30
自引率
0.00%
发文量
62
审稿时长
2 months
期刊介绍: Optical Review is an international journal published by the Optical Society of Japan. The scope of the journal is: General and physical optics; Quantum optics and spectroscopy; Information optics; Photonics and optoelectronics; Biomedical photonics and biological optics; Lasers; Nonlinear optics; Optical systems and technologies; Optical materials and manufacturing technologies; Vision; Infrared and short wavelength optics; Cross-disciplinary areas such as environmental, energy, food, agriculture and space technologies; Other optical methods and applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信